VAL-MS-T1/T2 48/12.5/1+1/1U/FM - Lightning/surge arrester type 1/2
Universal varistor-based plug-in lightning/surge arrester for 48 V DC applications with grounded return conductor (positive pole), without risk assessment for Lightning Protection Levels III and IV, with remote indication contact.
- Dual-channel, panel mountable surge protective device
- Orthogonal mounting orientation to plug
- Base element with floating remote indication contact
- Rack-mount 1U panel applications
Technical Specifications
Product properties
Product family | VALVETRAB MS |
IEC test classification | I / II |
IEC test classification | T1 / T2 |
IEC test classification | I |
EN type | T1 / T2 |
IEC power supply system | TN-S |
Type | DIN rail module, two-section, divisible |
Surge protection fault message | Optical, remote indicator contact |
Insulation characteristics
Pollution degree | 2 |
Electrical properties
Nominal frequency fN | 50 Hz (60 Hz) |
Indicator/remote signaling
Connection name | Remote fault indicator contact |
Switching function | Changeover contact |
Operating Voltage | 5 V AC ... 250 V AC |
Operating Voltage | 125 V AC (UL) |
Operating Voltage | 125 V DC (200 mA DC) |
Operating current | 5 mA AC ... 1.5 A |
Operating current | 1 A (UL) |
Operating current | 1 A (30 V DC) |
Connection data
Connection Method | Screw connection |
Screw thread | M5 |
Tightening torque | 2.5 Nm ... 3 Nm |
Tightening torque | 22 lbf-in. ... 26.5 lbf-in. (UL) |
Stripping length | 16 mm |
Conductor cross section flexible min. | 1.5 mm² |
Conductor cross section flexible max. | 25 mm² |
Conductor cross section, rigid min. | 1.5 mm² |
Conductor cross section, rigid max. | 35 mm² |
Conductor cross section AWG | 15 ... 2 |
Conductor cross section AWG | 10 ... 2 (UL) |
Remote fault indicator contact
Connection Method | Push-in spring connection |
Stripping length | 6 mm |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 0.5 mm² |
Conductor cross section, rigid min. | 0.14 mm² |
Conductor cross section, rigid max. | 0.5 mm² |
Conductor cross section AWG | 24 ... 20 (UL) |
Dimensions
Width | 70.6 mm |
Height | 40.6 mm |
Height unit | 1 U |
Depth | 98.1 mm |
Material specifications
Color | gray (RAL 7042) |
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V-0 |
Housing Material | PA 6.6 |
Housing Material | PBT |
Mechanical data
Open side panel | No |
Protective circuit
Mode of protection | L-N |
Mode of protection | N-PE |
Direction of action | L-N & L(N)-PE |
Nominal voltage UN | 60 V AC ±10 % (TN-S) |
Nominal voltage UN | -48 V DC ±10 % (RRH) |
Nominal frequency fN | 50 Hz (60 Hz) |
Maximum continuous voltage UC | 75 V AC |
Maximum continuous voltage UC | 100 V DC |
Rated load current IL | 80 A |
Residual current IPE | ≤ 0.6 mA |
Standby power consumption PC | ≤ 45.00 mVA |
Nominal discharge current In (8/20) µs | 12.5 kA |
Maximum discharge current Imax (8/20) µs | 30 kA |
Impulse discharge current (10/350) µs, charge | 6.25 As |
Impulse discharge current (10/350) µs, specific energy | 39 kJ/Ω |
Impulse discharge current (10/350) µs, peak value limp | 12.5 kA |
Total discharge current Itotal (8/20) µs | 50 kA |
Short-circuit current rating ISCCR | 25 kA |
Voltage protection level Up | ≤ 0.4 kV |
Residual voltage Ures | ≤ 0.4 kV (at In) |
Residual voltage Ures | ≤ 0.35 kV (at 10 kA) |
Residual voltage Ures | ≤ 0.3 kV (at 5 kA) |
Residual voltage Ures | ≤ 0.275 kV (at 4 kA) |
Residual voltage Ures | ≤ 0.25 kV (at 3 kA) |
TOV behavior at UT | 100 V AC (5 s / withstand mode) |
TOV behavior at UT | 130 V DC (5 s / withstand mode) |
Response time tA | ≤ 25 ns |
Max. backup fuse with V-type through wiring | 80 A AC (gG - 16 mm²) |
Max. backup fuse with branch wiring | 160 A AC (gG) |
Additional technical data
Maximum discharge current Imax (8/20) µs | 65 kA |
Ambient conditions
Degree of Protection | IP20 (only when all terminal points are used) |
Ambient Temperature (Operation) | -40 °C ... 80 °C |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m (amsl) |
Permissible humidity (operation) | 5 % ... 95 % |
Shock (operation) | 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
Vibration (Operation) | 7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
UL specifications
Maximum continuous operating voltage MCOV (L-N) | 75 V AC |
Maximum continuous operating voltage MCOV (L-N) | 100 V DC |
Mode of protection | N-G |
Mode of protection | L-N |
Mode of protection | (L+) - (L-) |
Mode of protection | (L+) - G |
Mode of protection | (L-) - G |
Nominal Voltage | 60 V DC |
SPD Type | 1CA |
UL indicator/remote signaling
Operating Voltage | 125 V AC |
AC operating current | 1 A AC |
UL connection data
Tightening torque | 30 lbf-in. |
Conductor cross section AWG | 10 ... 2 |
Mounting
Mounting Type | Panel mount |
Why Proax for Phoenix Contact 2909629?
Proax is an authorized distributor of Phoenix Contact 2909629 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended