VAL-MS-T1/T2 48/12.5/O-FM - Lightning/surge arrester type 1/2

Universal varistor-based plug-in lightning/surge arrester for 1-phase power supply networks with common N and PE (2-conductor system: L1, PEN), with remote indication contact.

  • Rack-mount 2U panel applications
  • Plug-in direction parallel to the conductor axis
  • DIN rail mounting
  • Coding when protective plug is inserted for the first time
  • Accepts Type 1 and Type 2 VAL-MS plugs
  • Versions with and without floating remote indication contact
Technical Specifications

Product properties

Product familyVALVETRAB MS
IEC test classificationI / II
IEC test classificationT1 / T2
IEC test classificationI
EN typeT1 / T2
IEC power supply systemDC
TypeDIN rail module, two-section, divisible
Number of Positions1
Surge protection fault messageOptical, remote indicator contact

Insulation characteristics

Pollution degree2

Electrical properties

Nominal frequency fN50 Hz (60 Hz)

Indicator/remote signaling

Connection nameRemote fault indicator contact
Switching functionChangeover contact
Operating Voltage5 V AC ... 250 V AC
Operating Voltage125 V AC (UL)
Operating Voltage125 V DC (200 mA DC)
Operating current5 mA AC ... 1.5 A
Operating current1 A (UL)
Operating current1 A (30 V DC)

Connection data

Connection MethodScrew connection
Screw threadM5
Tightening torque3 Nm ... 4.5 Nm (UL)
Tightening torque27 lbf-in. ... 40 lbf-in. (UL)
Stripping length16 mm
Conductor cross section flexible1.5 mm² ... 25 mm²
Conductor cross section rigid1.5 mm² ... 35 mm²
Conductor cross section AWG15 ... 2
Conductor cross section AWG10 ... 2 (UL)

Remote fault indicator contact

Connection MethodScrew connection
Screw threadM2
Tightening torque0.25 Nm
Stripping length7 mm
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16

Dimensions

Width17.5 mm
Height77.1 mm
Depth89.2 mm
Horizontal pitch1 Div.

Material specifications

Colorblack (RAL 9005)
Flammability rating according to UL 94V0
Housing MaterialPBT

Mechanical data

Open side panelNo

Protective circuit

Mode of protectionL-PEN
Mode of protection(L+) - (L-)
Mode of protection(L-) - PE
Mode of protection(L+) - PE
Direction of actionL-N / L-PEN
Nominal voltage UN-48 V DC (RRH)
Nominal voltage UN60 V DC
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC75 V AC
Maximum continuous voltage UC100 V DC
Maximum continuous operating voltage UC (L-N)75 V AC
Maximum continuous operating voltage UC (L-N)100 V DC
Maximum continuous operating voltage UC (L-PEN)75 V AC
Maximum continuous operating voltage UC (L-PEN)100 V DC
Rated load current IL80 A
Rated load current IL80 A
Residual current IPE≤ 0.6 mA
Residual current IPE≤ 0.6 mA
Standby power consumption PC≤ 45.00 mVA
Standby power consumption PC≤ 45.00 mVA
Nominal discharge current In (8/20) µs12.5 kA
Nominal discharge current In (8/20) µs (L-N)12.5 kA
Nominal discharge current In (8/20) µs (L-PEN)12.5 kA
Maximum discharge current Imax (8/20) µs30 kA
Maximum discharge current Imax (8/20) µs (L-N)30 kA
Maximum discharge current Imax (8/20) µs (L-PEN)30 kA
Impulse discharge current (10/350) µs, charge6.25 As
Impulse discharge current (10/350) µs, specific energy39 kJ/Ω
Impulse discharge current (10/350) µs, peak value limp12.5 kA
Impulse discharge current (10/350) µs, peak value limp12.5 kA
Impulse discharge current (10/350) µs (L-N), charge6.25 As
Impulse discharge current (10/350) µs (L-N), charge6.25 As
Impulse discharge current (10/350) µs (L-N), charge6.25 As
Impulse discharge current (10/350) µs (L-N), specific energy39 kJ/Ω
Impulse discharge current (10/350) µs (L-N), specific energy39 kJ/Ω
Impulse discharge current (10/350) µs (L-N), specific energy39 kJ/Ω
Impulse discharge current (10/350) µs (L-N), peak current value Iimp12.5 kA
Impulse discharge current (10/350) µs (L-N), peak current value Iimp12.5 kA
Impulse discharge current (10/350) µs (L-N), peak current value Iimp12.5 kA
Short-circuit current rating ISCCR25 kA
Voltage protection level Up≤ 0.4 kV
Voltage protection level Up (L-N)≤ 0.4 kV
Voltage protection level Up (L-PEN)≤ 0.4 kV
Residual voltage Ures≤ 0.4 kV (at In)
Residual voltage Ures≤ 0.35 kV (at 10 kA)
Residual voltage Ures≤ 0.3 kV (at 5 kA)
Residual voltage Ures≤ 0.275 kV (at 4 kA)
Residual voltage Ures≤ 0.25 kV (at 3 kA)
TOV behavior at UT100 V AC (5 s / withstand mode)
TOV behavior at UT130 V DC (5 s / withstand mode)
TOV behavior at UT (L-N)100 V AC (5 s / withstand mode)
TOV behavior at UT (L-N)130 V DC (5 s / withstand mode)
TOV behavior at UT (L-PEN)100 V AC (5 s / withstand mode)
TOV behavior at UT (L-PEN)130 V DC (5 s / withstand mode)
Response time tA≤ 25 ns
Response time tA (L-N)≤ 25 ns
Response time tA (L-PEN)≤ 25 ns
Max. backup fuse with V-type through wiring80 A AC (gG - 16 mm²)
Max. backup fuse with V-type through wiring80 A AC (gG - 16 mm²)
Max. backup fuse with branch wiring160 A AC (gG)
Max. backup fuse with branch wiring160 A AC (gG)

Additional technical data

Maximum discharge current Imax (8/20) µs65 kA

Ambient conditions

Degree of ProtectionIP20 (only when all terminal points are used)
Ambient Temperature (Operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitudemax. 2000 m
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (Operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

UL specifications

Maximum continuous operating voltage MCOV75 V AC
Maximum continuous operating voltage MCOV (L-N)75 V AC
Maximum continuous operating voltage MCOV (L-G)75 V AC
Maximum continuous operating voltage MCOV (L+) - (L-)100 V DC
Maximum continuous operating voltage MCOV (L+/L-) - G100 V DC
Voltage protection rating VPR400 V
Voltage protection rating VPR (L-N)400 V
Nominal discharge current In20 kA
Nominal discharge current In (L-G)20 kA
Nominal discharge current In (L+) - (L-)20 kA
Mode of protectionL-L
Mode of protectionL-G
Mode of protection(L+) - (L-)
Mode of protection(L+) - G
Mode of protection(L-) - G
Nominal Voltage60 V DC
Power distribution systemSingle phase
Measured limiting voltage MLV1240 V
Measured limiting voltage MLV (L-G)1240 V
Measured limiting voltage MLV (L+) - (L-)1230 V
SPD Type1CA

UL connection data

Tightening torque30 lbf-in.
Conductor cross section AWG10 ... 2

Air clearances and creepage distances

Standards/regulationsEN 61643-11 / UL 840
Standards/specificationsEN 61643-11/A11
Note2007

Mounting

Mounting TypeDIN rail: 35 mm
Accessories

Why Proax for Phoenix Contact VAL-MS-T1/T2 48/12.5/O-FM?

Proax is an authorized distributor of Phoenix Contact VAL-MS-T1/T2 48/12.5/O-FM and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesVALMST1T248125OFM
Pack Size12
Recommended
Sold in quantities of 12

Available for order