Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
ILB PN 24 DI16 DIO16-EF
Weight
0.564 kg
Series ILB-PN

ILB PN 24 DI16 DIO16-EF - I/O module

Inline, Block IO, PROFINET, RJ45 jack, Digital inputs: 32 (16 fixed and 16 freely selectable), 24 V DC, connection technology: 3-conductor, Digital outputs: 16, 24 V DC, connection technology: 2-conductor, PROFINET, -IRT, -MRP, -Fast Startup, degree of protection: IP20, including Inline connector

  • 16/32 inputs, 24 V DC
  • 16 outputs, 24 V DC, 500  mA
  • 2 RJ45 jacks at a 45° angle
Technical Specifications

Dimensions

Width156 mm
Height141 mm
Depth57 mm
Note on dimensionsSpecfications with connectors

PROFINET

No. of channels2
Connection MethodRJ45 jack
Note on the connection methodAutonegotiation and autocrossing, X2: internally crossed to enable “Fast Startup” with patch cable
Designation connection pointX1, X2
Transmission Speed100 Mbps (acc. to PROFINET standard)
Transmission physicsEthernet in RJ45 twisted pair
Device functionPROFINET device
SpecificationVersion 2.3
Update ratemin. 1 ms (up to max. 512 ms, adjustable)
Conformance classC

Digital:

Input nameDigital inputs
Description of the inputEN 61131-2 types 1 and 3
Number of Inputs32 (16 fixed and 16 freely selectable)
Connection MethodInline connector
Connection technology3-conductor
Input Voltage24 V DC
Input voltage range "0" signal-3 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Nominal input voltage UIN24 V DC
Nominal input current at UINapprox. 2.4 mA
Typical input current per channeltyp. 5 mA
Typical response timeapprox. 500 µs
Output nameDigital outputs
Connection MethodInline connector
Connection technology2-conductor
Number of Outputs16
Protective circuitShort-circuit and overload protection; Free-wheeling diode, integrated per channel
Output Voltage24 V DC -1 V (At nominal current)
Limitation of the voltage induced on circuit interruption-25.8 V ... -15 V
Maximum Output Current per channel500 mA
Maximum Output Current per module8 A
Nominal Output Voltage24 V DC
Output current when switched offmax. 300 µA (When not loaded, a voltage can be measured even at an output that is not set.)
Nominal load, inductive12 VA (1.2 H, 48 Ω)
Nominal load, lamp12 W
Nominal load, ohmic12 W (48 Ω)
Reverse voltage resistance to short pulseslimited protection up to 0.5 A for 1 s
Behavior with overloadAuto restart
Behavior with inductive overloadOutput can be destroyed
Behavior at voltage switch-offThe output follows the power supply without delay
Overcurrent shut-downas of 0.7 A

Product properties

Product familyInline
TypeBlock design
Scope of deliveryincluding Inline connector
Special PropertiesPROFINET, -IRT, -MRP, -Fast Startup
Diagnostics messagesShort-circuit or overload of the digital outputs Message in the diagnostics register
Diagnostics messagesShort circuit sensor supply US1 or US2 Message in the diagnostics register
Diagnostics messagesSensor supply US1 not present Message in the diagnostics register
Diagnostics messagesSensor supply US2 not present Message in the diagnostics register

Insulation characteristics

Overvoltage categoryII

Supply:

DesignationLogic (UL)
Connection MethodInline connector
Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptionmax. 75 mA
DesignationSensor supply (US1, US2)
Connection MethodInline connector
Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptionmax. 4 A (max. 2 A from US1 and 2 A from US2)
DesignationActuator supply (UA1, UA2)
Connection MethodInline connector
Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptionmax. 8 A (max. 4 A from UA1 and 4 A from UA2)

Electrical isolation/isolation of the voltage ranges

Test voltage: I/Os / logic500 V AC, 50 Hz, 1 min.
Test voltage: I/O/functional ground500 V AC, 50 Hz, 1 min.
Test voltage: Logic/functional ground500 V AC, 50 Hz, 1 min.
Test voltage: Ethernet interface signals / logic1500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameInline connector

Conductor connection

Connection MethodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Inline connector

Connection MethodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 60 °C
Degree of ProtectionIP20
Air pressure (operation)80 kPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)66 kPa ... 108 kPa (up to 3500 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2702289?

Proax is an authorized distributor of Phoenix Contact 2702289 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability