1423303
SKU
PHX1423303
MPN
NBC-MSX/ 2,0-94C/MSX SCO
Weight
0.158 kg
Series NBC-MSX
NBC-MSX/ 2,0-94C/MSX SCO - Network cable
Network cable, Ethernet CAT5 (1 Gbps) CAT5 (1 Gbps), 8-position, PUR halogen-free, water blue RAL 5021, shielded (Tinned copper braided shield), Advanced Shielding Technology, Plug straight M12, coding: X / IP67, on Plug straight M12, coding: X / IP67, cable length: 2 m
Technical Specifications
Product properties
| Application | Standard |
| Sensor Type | Ethernet |
| Number of Positions | 8 |
| No. of cable outlets | 1 |
| Shielded | yes |
| Coding | X |
Interfaces
| Bus system | Ethernet |
| Signal type/category | Ethernet CAT5 (IEC 11801:2002), 1 Gbps |
Signaling
| Status display | No |
| Status display present | No |
Electrical properties
| Nominal voltage UN | 48 V AC |
| Nominal voltage UN | 60 V DC |
| Nominal current IN | 0.5 A |
| Transmission medium | Copper |
| Transmission characteristics (category) | CAT5 |
Connection 1
| Type | Plug straight M12 / IP67 |
| Number of Positions | 8 |
| Coding type | X (Data) |
| Handle color | black |
| Material | CuZn (Contact) |
| Material | Ni/Au (Contact surface) |
| Material | PP (Contact carriers) |
| Material | TPU, hardly inflammable, self-extinguishing (Grip) |
| Material | Zinc die-cast, nickel-plated (Screw connection) |
| Insertion/withdrawal cycles | ≥ 100 |
| Insulation resistance | ≥ 100 MΩ |
| Tightening torque | 0.4 Nm |
| Degree of Protection | IP67 |
| Ambient Temperature (Operation) | -25 °C ... 90 °C |
Connection 2
| Type | Plug straight M12 / IP67 |
| Coding type | X (Data) |
| Material | CuZn (Contact) |
| Material | Ni/Au (Contact surface) |
| Material | PC (Contact carriers) |
| Material | PA (Housing) |
| Insertion/withdrawal cycles | ≥ 100 |
| Insulation resistance | ≥ 100 MΩ |
| Tightening torque | 0.4 Nm |
| Degree of Protection | IP67 |
| Ambient Temperature (Operation) | -25 °C ... 90 °C |
Cable/line
| Cable Length | 2 m |
Ethernet drag chain CAT5, 4-pair [94C]
| Cable weight | 57 kg/km |
| UL AWM style | 20963 (80°C/30 V) |
| Number of Positions | 8 |
| Shielded | yes |
| Cable Type | Ethernet drag chain CAT5, 4-pair [94C] |
| Conductor structure | 4x2xAWG26/19, S/UTP |
| Signal runtime | 5.3 ns/m |
| Conductor structure signal line | 19x 0.10 mm |
| AWG Signal Line | 26 |
| Conductor Cross Section | 4x 2x 0.14 mm² |
| Wire diameter incl. insulation | 1 mm |
| External Cable Diameter | 6.90 mm +0.1 mm ... 0.2 mm |
| Outer sheath, material | PUR |
| External sheath, color | water blue RAL 5021 |
| Conductor material | Bare Cu litz wires |
| Material wire insulation | PP |
| Single wire, color | white/blue-blue, white/orange-orange, white/green-green, white/brown-brown |
| Thickness, outer sheath | 0.85 mm |
| Twisted pairs | 2 cores to the pair |
| Overall twist | Four pairs and four fillers to the core |
| Optical shield covering | 90 % |
| Insulation resistance | ≥ 500 MΩ*km |
| Coupling resistance | ≤ 100.00 mΩ/m (at 10 MHz) |
| Loop resistance | ≤ 290.00 Ω/km |
| Wave impedance | 100 Ω ±5 Ω (at 100 MHz) |
| Cable capacity | approx. 50 nF/km (at 1 kHz) |
| Nominal voltage, cable | ≤ 100 V |
| Test voltage Core/Core | 700 V (50 Hz, 1 min.) |
| Test voltage Core/Shield | 700.00 V (50 Hz, 1 min.) |
| Minimum bending radius, fixed installation | 4 x D |
| Minimum bending radius, flexible installation | 8 x D |
| Smallest bending radius, fixed installation | 28 mm |
| Smallest bending radius, movable installation | 56 mm |
| Max. bending cycles | 5000000 |
| Tensile strength | ≤ 100 N |
| Near end crosstalk attenuation (NEXT) | 65.3 dB (with 1 MHz) |
| Near end crosstalk attenuation (NEXT) | 56.3 dB (at 4 МHz) |
| Near end crosstalk attenuation (NEXT) | 50.3 dB (at 10 MHz) |
| Near end crosstalk attenuation (NEXT) | 47.2 dB (at 16 MHz) |
| Near end crosstalk attenuation (NEXT) | 45.8 dB (at 20 МHz) |
| Near end crosstalk attenuation (NEXT) | 42.9 dB (at 31.25 МHz) |
| Near end crosstalk attenuation (NEXT) | 38.4 dB (at 62.5 МHz) |
| Near end crosstalk attenuation (NEXT) | 35.3 dB (at 100 MHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 62.3 dB (with 1 MHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 53.3 dB (at 4 МHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 47.3 dB (at 10 MHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 44.2 dB (at 16 MHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 42.8 dB (at 20 МHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 39.9 dB (at 31.25 МHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 35.4 dB (at 62.5 МHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 32.3 dB (at 100 MHz) |
| Return attenuation (RL) | 23 dB (at 4 МHz) |
| Return attenuation (RL) | 24.1 dB (at 8 МHz) |
| Return attenuation (RL) | 25 dB (at 10 MHz) |
| Return attenuation (RL) | 25 dB (at 16 MHz) |
| Return attenuation (RL) | 25 dB (at 20 МHz) |
| Return attenuation (RL) | 23.6 dB (at 31.25 МHz) |
| Return attenuation (RL) | 21.5 dB (at 62.5 МHz) |
| Return attenuation (RL) | 20.1 dB (at 100 MHz) |
| Shield attenuation | 3.2 dB (with 1 MHz) |
| Shield attenuation | 6 dB (at 4 МHz) |
| Shield attenuation | 9.5 dB (at 10 MHz) |
| Shield attenuation | 12.1 dB (at 16 MHz) |
| Shield attenuation | 13.6 dB (at 20 МHz) |
| Shield attenuation | 17.1 dB (at 31.25 МHz) |
| Shield attenuation | 24.8 dB (at 62.5 МHz) |
| Shield attenuation | 32 dB (at 100 MHz) |
| Halogen-free | according to IEC 60754-1 |
| Flame resistance | according to IEC 60332-1-2 |
| Resistance to Oil | in accordance with EN 60811-2-1 |
| Ambient Temperature (Operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Ambient Temperature (Operation) | -20 °C ... 80 °C (Cable, flexible installation) |
| Ambient temperature (installation) | -20 °C ... 80 °C |
Ambient conditions
| Degree of Protection | IP65/IP67 |
| Ambient Temperature (Operation) | -25 °C ... 90 °C (M12 connector) |
Standards and Regulations
| Standard designation | M12 connector |
| Standards/specifications | IEC 61076-2-109 |
Why Proax for Phoenix Contact 1423303?
Proax is an authorized distributor of Phoenix Contact 1423303 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended
NBC-MSY/ 2,0-94H/MSY SCO - Hybrid cable, Ethernet hybrid CAT5 (100 Mbps), 8-position, PUR halogen-free, black RAL 9005, shielded (Tinned copper braided shield), Plug straight M12 SPEEDCON, coding: Y / IP67, on Plug straight M12 SPEEDCON, coding: Y / IP67, cable length: 2 m, Power with Ethernet (PWE)
NBC-MSY/ 1,0-94H/MSY SCO - Hybrid cable, Ethernet hybrid CAT5 (100 Mbps), 8-position, PUR halogen-free, black RAL 9005, shielded (Tinned copper braided shield), Plug straight M12 SPEEDCON, coding: Y / IP67, on Plug straight M12 SPEEDCON, coding: Y / IP67, cable length: 1 m, Power with Ethernet (PWE)
NBC-MSY/ 0,7-94H/MSY SCO - Hybrid cable, Ethernet hybrid CAT5 (100 Mbps), Ethernet hybrid CAT5 (100 Mbps), 8-position, PUR halogen-free, black RAL 9005, shielded (Tinned copper braided shield), Plug straight M12 SPEEDCON, coding: Y / IP67, on Plug straight M12 SPEEDCON, coding: Y / IP67, cable length: 0.7 m, Power with Ethernet (PWE)
NBC-MSY/ 5,0-94H/MSY SCO - Hybrid cable, Ethernet hybrid CAT5 (100 Mbps), 8-position, PUR halogen-free, black RAL 9005, shielded (Tinned copper braided shield), Plug straight M12 SPEEDCON, coding: Y / IP67, on Plug straight M12 SPEEDCON, coding: Y / IP67, cable length: 5 m, Power with Ethernet (PWE)