The CM-TCN.011S is an innovative temperature monitoring relay from the CM temperature monitors range. This monitoring relay operates with a rated control supply voltage of 24 - 240 V AC / DC and has a 3 c/o (SPDT) output with contacts rated at 250 V / 4 A. The CM-TCN.011S is able to measure temperatures with up to three sensor circuits using different type of sensors PT100, PT1000, PTC or NTC. The LCD at the front of the relay shows the currently measured values and maintenance data. The CM-TCN.011S can be configured exactly as you need either via a black-lit LCD or smartphone app. Parametrization and configuration are just one touch away with the ABB EPiC app – even in a non-powered state – reducing installation time by 80%. The device offers screw connection technology with double-chamber cage connection terminals.
Technical Specifications
Supplier Information - USINY
| Lead Time | 49 day |
| Made to Order | No |
| Product Sales Status | Active |
| Quote Only | No |
| Stocked At Warehouses | USSVCEXPU |
| Warranty Return | Product under warranty must be returned |
Dimensions
| Product Net Width | 45 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.265 kg |
Technical
| Function | Overtemperature monitoring |
| Function | Undertemperature monitoring |
| Function | Over- and undertemperature monitoring |
| Measuring Range | -200 ... 850 °C |
| Sensor Type | PT100 |
| Sensor Type | PTC |
| Sensor Type | Bimetal Switch |
| Sensor Type | NTC |
| Sensor Type | PT1000 |
| Rated Control Supply Voltage (Us) | 24 ... 240 V AC/DC |
| Rated Frequency (f) | Supply Circuit 50 Hz |
| Rated Frequency (f) | Supply Circuit 60 Hz |
| Rated Frequency (f) | Supply Circuit DC Hz |
| Output | 3 x 1 c/o contacts, configurable |
| Terminal Type | Screw Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum switching capacity | 12 V |
| Minimum switching capacity | 100 mA |
| Rated Impulse Withstand Voltage (Uimp) | Measuring Circuit / Output Circuit 6 kV |
| Rated Impulse Withstand Voltage (Uimp) | Output Circuit 1 / Output Circuit 2 4 kV |
| Rated Impulse Withstand Voltage (Uimp) | Supply Circuit / Measuring Circuit 6 kV |
| Rated Impulse Withstand Voltage (Uimp) | Supply Circuit / Output Circuit 6 kV |
| Rated Insulation Voltage (Ui) | Measuring Circuit / Output Circuit 600 V |
| Rated Insulation Voltage (Ui) | Output Circuit 1 / Output Circuit 2 300 V |
| Rated Insulation Voltage (Ui) | Supply Circuit / Measuring Circuit 600 V |
| Rated Insulation Voltage (Ui) | Supply Circuit / Output Circuit 600 V |
| Degree of Protection | Housing IP50 |
| Degree of Protection | Terminals IP20 |
| Overvoltage category | III |
| Pollution degree | 2 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Short-Circuit Protective Devices | Output Circuit NO - F Type Fuses 10 A |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible with Ferrule 1x 0.5 ... 2.5 mm² |
| Connecting Capacity | Flexible with Ferrule 2x 0.5 ... 1.5 mm² |
| Connecting Capacity | Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² |
| Connecting Capacity | Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² |
| Connecting Capacity | Flexible 1x 0.5 ... 2.5 mm² |
| Connecting Capacity | Flexible 2x 0.5 ... 1.5 mm² |
| Connecting Capacity | Rigid 1x 0.5 ... 4 mm² |
| Connecting Capacity | Rigid 2x 0.5 ... 2.5 mm² |
| Tightening torque | 0.6 ... 0.8 N·m |
| Wire Stripping Length | 8 mm |
| Recommended Screw Driver | 0.8 x 4 |
| Recommended Screw Driver | 4.5 |
| Recommended Screw Driver | Pozidriv 1 |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Technical UL/CSA
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 1x 18-14 AWG |
| Connecting Capacity UL/CSA | Flexible 2x 18-16 AWG |
| Connecting Capacity UL/CSA | Rigid 1x 20-12 AWG |
| Connecting Capacity UL/CSA | Rigid 2x 20-14 AWG |
| Tightening Torque UL/CSA | 7.08 in·lb |
| Pilot Duty UL/CSA | B300 |
ABB EcoSolutions
| ABB EcoSolutions | Yes |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
Why Proax for ABB CM-TCN.011S?
Proax is an authorized distributor of ABB CM-TCN.011S and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Alternate Names | CMTCN011S |
| Pack Size | 1 |
Recommended