Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
PLC-RSC-120UC/21/SO46
Weight
0.041 kg
Series PLC-RSC

PLC-RSC-120UC/21/SO46 - Relay Module

PLC-INTERFACE for protection against interference currents or interference voltages on the control side. Consisting of PLC-BSC-120UC/21/SO46 basic terminal block with screw connection and plug-in miniature relay with power contact up to 6 A, 1 changeover contact, input voltage: 120 V AC

  • Slim design
  • Resistant to interference currents
  • Efficient connection to system cabling using V8 adapter
  • Safe isolation according to DIN EN 50178 between coil and contact
  • RT III sealed relay
  • Functional plug-in bridges
Technical Specifications

Notes

GeneralSeparating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or FBST 500....
GeneralThe PLC-ATP separating plate should be installed for safe isolation between adjacent modules
GeneralThe PLC-ATP separating plate is required at the start and end of every PLC terminal strip.
GeneralThe system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact.

Product properties

Product familyPLC-INTERFACE
ApplicationFilter to prevent interference
Operating mode100% operating factor
Mechanical service life2x 107 cycles

Insulation characteristics: Air clearances and creepage distances between the power circuits

InsulationSafe isolation, reinforced insulation
Overvoltage categoryIII
Pollution degree3

Electrical properties

Maximum power dissipation for nominal condition0.84 W
Test voltage (Winding/contact)4 kV AC (50 Hz, 1 min., winding/contact)

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V AC
Rated surge voltage6 kV

Coil side

Nominal input voltage UN120 V AC
Nominal input voltage UN110 V DC
Input voltage range93.6 V AC ... 168 V AC (20 °C)
Input voltage range85.8 V DC ... 154 V DC (20 °C)
Mains frequency50/60 Hz
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN7 mA (50 Hz)
Typical input current at UN8 mA (60 Hz)
Typical response time7 ms
Typical release time20 ms
Typical release voltage50 V AC
Coil Voltage60 V DC
Protective circuitBridge rectifier
Protective circuitRC element
Status displayYellow LED

Switching

Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact MaterialAgSnO
Maximum Switching Voltage250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum Switching Voltage5 V (100 mA)
Limiting Continuous Current6 A
Maximum Inrush Current10 A (4 s)
Min. switching current10 mA (12 V)
Interrupting rating (ohmic load) max.140 W (24 V DC)
Interrupting rating (ohmic load) max.20 W (48 V DC)
Interrupting rating (ohmic load) max.18 W (60 V DC)
Interrupting rating (ohmic load) max.23 W (110 V DC)
Interrupting rating (ohmic load) max.40 W (220 V DC)
Interrupting rating (ohmic load) max.1500 VA (250 V AC)
Switching capacity min.0.12 W
Switching capacity2 A (at 24 V, DC13)
Switching capacity0.2 A (at 110 V, DC13)
Switching capacity0.1 A (at 220 V, DC13)
Switching capacity3 A (at 24 V, AC15)
Switching capacity3 A (at 120 V, AC15)
Switching capacity3 A (at 230 V, AC15)

Connection data

Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm² (Single ferrule)
Conductor cross section flexible2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14
Tightening torque0.6 Nm ... 0.8 Nm

Dimensions

Width6.2 mm
Height80 mm
Depth94 mm

Material specifications

Flammability rating according to UL 94V0 (Housing)

Ambient conditions

Degree of protection (Relay)RT III (Relay)
Degree of protection (Relay base)IP20 (Relay base)
Degree of protection (Installation location)IP54 (Installation location)
Ambient Temperature (Operation)-40 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m

Corrosive gas test

IdentificationISA-S71.04. G3 Harsh Group
IdentificationEN 60068-2-60

Standards/regulations

Standards/regulationsEN 50178
Standards/regulationsEN 61810

Air clearances and creepage distances between the power circuits

Standards/regulationsDIN EN 50178

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany
Accessories

Why Proax for Phoenix Contact 5603593?

Proax is an authorized distributor of Phoenix Contact 5603593 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability