Proax
CADEN
proax logo
Cart

3005073

Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
PHX3005073
MPN
UK 10 N
Weight
0.017 kg
Series UK

UK 10 N - Feed-through terminal block

Feed-through terminal block, nom. voltage: 800 V, nominal current: 57 A, number of connections: 2, connection method: Screw connection, Rated cross section: 10 mm2, cross section: 0.5 mm2 - 16 mm2, mounting type: NS 35/7,5, NS 35/15, NS 32, color: gray

  • All universal terminal blocks in the UK... series can also be used in the Ex e area according to IEC/EN 60079 as standard
  • The corresponding EC-type examination numbers for Ex approval can be found in the technical connection data
Technical Specifications

Product properties

Product familyUK
Number of Connections2
Number of rows1
Potentials1

Insulation characteristics

Overvoltage categoryIII
Degree of pollution3

Electrical properties

Rated surge voltage8 kV
Maximum power dissipation for nominal condition1.82 W

Connection data

Number of connections per level2
Nominal cross section10 mm²

Level 1 above 1 below 1

Screw threadM4
Tightening torque1.5 ... 1.8 Nm
Stripping length10 mm
Internal cylindrical gageB6
Connection in acc. with standardIEC 60947-7-1
Conductor cross section rigid0.5 mm² ... 16 mm²
Cross section AWG20 ... 6 (converted acc. to IEC)
Conductor cross section flexible0.5 mm² ... 10 mm²
Conductor cross section, flexible [AWG]20 ... 8 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.5 mm² ... 10 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.5 mm² ... 6 mm²
Cross-section with insertion bridge, rigid10 mm²
Cross-section with insertion bridge, flexible10 mm²
2 conductors with same cross section, solid0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve0.5 mm² ... 2.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 6 mm²
Nominal Current57 A
Maximum Load Current76 A (with 16 mm² conductor cross section)
Nominal Voltage800 V
Nominal cross section10 mm²

Rated data (ATEX/IECEx)

Identification II 2 GD  Ex eb IIC Gb
Operating temperature range-60 °C ... 110 °C
Ex-certified accessories3003020 D-UK 4/10
Ex-certified accessories3006027 D-UK 16
Ex-certified accessories3004210 ATP-UK 5-MTK
Ex-certified accessories1205066 SZS 1,0X4,0 VDE
Ex-certified accessories1201442 E/UK
List of bridgesFixed bridge / FBI 10-10-EX / 0711690
Bridge data51.5 A / 10 mm²
List of bridgesInsertion bridge / EB 2-10 / 0203153
List of bridgesInsertion bridge / EB 3-10 / 0203328
List of bridgesInsertion bridge / EB 10-10 / 0203137
Bridge data50 A / 10 mm²
Ex temperature increase40 K (59.1 A / 10 mm²)
Rated voltage690 V
at bridging with insertion bridge690 V
for bridging with bridge690 V
Rated Insulation Voltage630 V
Output(Permanent)

Ex level General

Rated current53.5 A
Maximum Load Current67 A
Contact resistance0.12 mΩ

Ex connection data General

Torque range1.5 Nm ... 1.8 Nm
Nominal cross section10 mm²
Rated cross section AWG8
Connection capacity rigid0.5 mm² ... 16 mm²
Connection capacity AWG20 ... 6
Connection capacity flexible0.5 mm² ... 10 mm²
Connection capacity AWG20 ... 8
2 conductors with same cross section, solid0.5 mm² ... 4 mm²
2 conductors with the same cross-section AWG rigid20 ... 12
2 conductors with same cross section, stranded0.5 mm² ... 4 mm²
2 conductors with the same cross-section AWG flexible20 ... 12

Dimensions

Width10.2 mm
End cover width1.8 mm
Height42.5 mm
Depth on NS 3252.3 mm
Depth on NS 35/7,547.3 mm
Depth on NS 35/1554.8 mm

Material specifications

Colorgray
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Surge voltage test

Test voltage setpoint9.8 kV
ResultTest passed

Temperature-rise test

Requirement temperature-rise testIncrease in temperature ≤ 45 K
ResultTest passed
Short-time withstand current 10 mm²1.2 kA
Short-time withstand current 16 mm²1.92 kA
ResultTest passed

Power-frequency withstand voltage

Test voltage setpoint2 kV
ResultTest passed

Mechanical data

Open side panelYes

Mechanical strength

ResultTest passed

Attachment on the carrier

DIN rail/fixing supportNS 32/NS 35
Test force setpoint5 N
ResultTest passed

Test for conductor damage and slackening

Rotation speed10 rpm
Revolutions135
Conductor cross section/weight0.5 mm² / 0.3 kg
Conductor cross section/weight10 mm² / 2 kg
Conductor cross section/weight16 mm² / 2.9 kg
ResultTest passed

Needle-flame test

Time of exposure30 s
ResultTest passed

Oscillation/broadband noise

SpecificationDIN EN 50155 (VDE 0115-200):2008-03
SpectrumService life test category 1, class B, body mounted
Frequencyf1 = 5 Hz to f2 = 150 Hz
ASD level1.857 (m/s²)²/Hz
Acceleration0.8g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
ResultTest passed

Shocks

SpecificationDIN EN 50155 (VDE 0115-200):2008-03
Pulse shapeHalf-sine
Acceleration5g
Shock duration30 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
ResultTest passed

Ambient conditions

Ambient Temperature (Operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (operation)20 % ... 90 %
Permissible humidity (storage/transport)30 % ... 70 %

Standards and Regulations

Connection in acc. with standardIEC 60947-7-1

Mounting

Mounting TypeNS 35/7,5
Mounting TypeNS 35/15
Mounting TypeNS 32
Accessories

Why Proax for Phoenix Contact 3005073?

Proax is an authorized distributor of Phoenix Contact 3005073 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size50
Recommended
Sold in quantities of 50

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability