2920052
SKU
PHX2920052
Weight
0.031 kg
This product is Not Cancellable/Not Returnable
Surge protection plug - PT 1X2-5DC/FM-ST
Surge protection plug with integrated diagnostic and status indicator on the module and remote indication contact for a 2-wire floating signal circuit.
- Permanent protective device monitoring with optical signaling via LED
- Maximum ease of maintenance thanks to the two-piece design
- The signal is not influenced during maintenance work, thanks to the impedance-neutral insertion and removal of protective plugs
- Easy selection for all possible demands in MCR applications with a complete product portfolio
- Easy testing and documentation with CHECKMASTER 2 with pluggable protective modules
Technical Specifications
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
Dimensions
| Height | 45 mm |
| Width | 17.7 mm |
| Depth | 52 mm |
| Horizontal pitch | 1 Div. |
| Complete module height | 90 mm |
| Complete module width | 17.7 mm |
| Complete module depth | 65.5 mm |
Ambient conditions
| Ambient Temperature (Operation) | -40 °C ... 85 °C |
| Degree of Protection | IP20 |
General
| Housing Material | PA 6.6 |
| Flammability rating according to UL 94 | V-0 |
| Color | black |
| Standards for cearances and creepage distances | VDE 0110-1 |
| Standards for cearances and creepage distances | IEC 60664-1 |
| Mounting Type | on base element |
| Type | Male |
| Direction of action | Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground |
Protective circuit
| IEC test classification | C1 |
| IEC test classification | C2 |
| IEC test classification | C3 |
| IEC test classification | D1 |
| VDE requirement class | C1 |
| VDE requirement class | C2 |
| VDE requirement class | C3 |
| VDE requirement class | D1 |
| Nominal voltage UN | 5 V DC |
| Maximum continuous voltage UC | 6 V DC |
| Maximum continuous voltage UC | 4 V AC |
| Rated current | 450 mA (45 °C) |
| Operating effective current IC at UC | ≤ 1 mA |
| Residual current IPE | ≤ 2 µA (Directly grounded) |
| Residual current IPE | ≤ 1 µA (with PT 1X2+F-BE) |
| Nominal discharge current In (8/20) µs (line-line) | 10 kA |
| Nominal discharge current In (8/20) µs (line-earth) | 10 kA |
| Pulse discharge current Iimp (10/350) µs | 2.5 kA |
| Total discharge current Itotal (8/20) µs | 20 kA |
| Max. discharge current Imax (8/20) µs maximum (line-line) | 10 kA |
| Max. discharge current Imax (8/20) µs maximum (line-earth) | 10 kA |
| Nominal pulse current Ian (10/1000) µs (line-line) | 125 A (25 °C / 1x) |
| Nominal pulse current Ian (10/1000) µs (line-line) | 50 A (25 °C) |
| Output voltage limitation at 1 kV/µs (line-line) spike | ≤ 15 V |
| Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 450 V |
| Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 1 kV (with PT 1X2+F-BE) |
| Output voltage limitation at 1 kV/µs (line-line) static | ≤ 11 V |
| Residual voltage at In (line-line) | ≤ 10 V |
| Residual voltage with Ian (10/1000) µs (line-line) | ≤ 12 V |
| Voltage protection level Up (line-line) | ≤ 11 V (C1 - 500 V / 250 A) |
| Voltage protection level Up (line-line) | ≤ 10 V (C3 - 25 A) |
| Voltage protection level Up (line-earth) | ≤ 450 V (C2 - 10 kV / 5 kA) |
| Response time tA (line-line) | ≤ 1 ns |
| Response time tA (line-earth) | ≤ 100 ns |
| Input attenuation aE, sym. | typ. 0.5 dB (≤ 200 kHz / 50 Ω) |
| Input attenuation aE, sym. | typ. 0.2 dB (≤ 100 kHz / 150 Ω) |
| Cut-off frequency fg (3 dB), sym. in 50 Ω system | typ. 1 MHz |
| Cut-off frequency fg (3 dB), sym. in 150 Ω system | typ. 0.4 MHz |
| Capacity (line-line) | typ. 6 nF |
| Capacity (line-earth) | typ. 4 pF |
| Resistance per path | 2.2 Ω ±10 % (7-8/11-12) |
| Surge protection fault message | Optical, remote indicator contact |
| Max. required back-up fuse | 500 mA (T) |
| Impulse durability (line-line) | C2 - 10 kV / 5 kA |
| Impulse durability (line-line) | C3 - 25 A |
| Impulse durability (line-earth) | C2 - 10 kV / 5 kA |
| Impulse durability (line-earth) | D1 - 2.5 kA |
| Impulse durability (line-earth) | C3 - 100 A |
| Alternating current carrying capacity (line-earth) | 5 A - 1 s |
Connection data
| Connection Method | Screw connection (in connection with the base element) |
| Screw thread | M3 |
| Tightening torque | 0.8 Nm |
| Stripping length | 8 mm |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section AWG | 24 ... 12 |
Standards and Regulations
| Standards/specifications | IEC 61643-21 2002 |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
| China RoHS | Environmentally Friendly Use Period = 50 years |
| China RoHS | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Accessories
Why Proax for Phoenix Contact 2920052?
Proax is an authorized distributor of Phoenix Contact 2920052 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |