Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
EEM-MA600
Weight
0.822 kg
This product has been discontinued and replaced with 2907945
Series EEM-MA

EEM-MA600 - Measuring instrument

Energy measurement device to measure electrical parameters in low voltage installations up to 700 V, acquisition of individual harmonic oscillations - can be extended with communication and special functional modules

  • Can be extended with special function and communication modules
Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Electrical properties

Electrical isolationEN 61010-1 (Safe isolation)
Electrical isolationSee extension module
Electrical isolationSee extension module
Test voltage3.5 kV AC (50 Hz, 1 min.)
Maximum power dissipation for nominal condition10 VA
Mains type3-phase (3 or 4-conductor), 2-phase (2-conductor), and single-phase (1-conductor)

Electrical isolation

Overvoltage categoryIII (For mains voltage <300 V AC (L/N))
Overvoltage categoryII (for mains voltage >300 V AC ... 600 V AC (L/N))
Pollution degree2

Supply

Supply Voltage230 V AC
Supply Voltage400 V AC
Supply Voltage Range110 V AC ... 400 V AC ±10 %
Supply Voltage Range120 V DC ... 350 V DC (±20 %)
Nominal Power Consumption10 VA
Power consumption20 VA (with max. number of extension modules)

General

Measuring PrincipleTrue r.m.s. value measurement
Measured valueAC sine (50 Hz/60 Hz)
Acquisition of harmonicsup to 63rd harmonic
Voltage input signalVia function module

Measurement: Voltage

Input nameVoltage measuring input V1, V2, V3
Input Voltage500 kV AC (Primary, via external voltage transducers)
Input VoltageSecondary: 60, 100, 110, 115, 120, 173, 190 V AC
Input voltage range18 V AC ... 700 V AC (Phase/Phase)
Input voltage range11 V AC ... 404 V AC (Phase/neutral conductor)
Precision0.2 %

Measurement: Current

Input nameCurrent measurement I1, I2, I3
Input current rangevia external transformers
Input Current9999 A (primary)
Input Current1 A and 5 A, secondary
Measuring Range0 A ... 9999 A
Overload capacity6 A (Permanent)
Response threshold from measuring range nominal value10 mA
Precision0.2 %
Current overload10 x IN for 1 s

Measurement: Power

Messbereich_Leistung0 MW ... 8000 MW
Messbereich_Leistung0 Mvar ... 8000 Mvar
Messbereich_Leistung0 MVA ... 8000 MVA
Precision0.5 %
Active energy (IEC 62053-22)Class 0.5 S
Reactive power (IEC 62053-23)Class 2

Output data

Output descriptionVia function module

Connection data

Connection MethodCOMBICON plug-in screw terminal block
NoteConnections for current, voltage, and supply
Conductor cross section rigid0.2 mm² ... 6 mm²
Conductor cross section flexible0.2 mm² ... 4 mm²
Connection MethodScrew connection
NoteConnections for digital I/O and communication
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²

Dimensions

Width96 mm
Height96 mm
Depth82 mm
Depth80 mm (Installation depth with extension module)
Depth60 mm (Installation depth without extension module)

Material specifications

Colorblack (RAL 9005)

Ambient conditions

Degree of ProtectionIP52 (Front)
Degree of ProtectionIP30 (On the rear)
Ambient Temperature (Operation)-10 °C ... 55 °C (14 °F ... 131 °F)
Ambient temperature (storage/transport)-20 °C ... 85 °C (-4 °F ... 185 °F)
Max. permissible relative humidity (operation)≤ 95 %
Max. salt spray content≤ 2.5 %

CE

CertificateCE-compliant

UL, USA/Canada

IdentificationUL 61010-1
IdentificationCSA-C22.2 No. 61010-1
IdentificationcULus

UL data

Nominal supply voltage range110 V AC ... 240 V AC ±10 %
Nominal supply voltage range120 V DC ... 250 V DC ±10 %
Power consumption10 VA
Altitude≤ 2000 m
Operating modeIndoor use
Surge voltagesTransient overvoltage according to installation classes
Overvoltage categoryI, II, III
Overvoltage category of the supplyMin. II
Ambient Temperature (Operation)0 °C ... 40 °C
Max. permissible relative humidity (operation)80 % (up to 31 °C)
Max. permissible relative humidity (operation)50 % (at 40 °C)
Nominal supply voltage range110 V AC ... 240 V AC ±10 %
Nominal supply voltage range120 V DC ... 250 V DC ±10 %
Power consumption10 VA
Altitude≤ 2000 m
Operating modeIndoor use
Ambient Temperature (Operation)0 °C ... 40 °C
Max. permissible relative humidity (operation)80 % (up to 31 °C)
Max. permissible relative humidity (operation)50 % (at 40 °C)
Surge voltagesTransient overvoltage according to installation classes
Overvoltage categoryI, II, III
Overvoltage category of the supplyMin. II

Mounting

Mounting PositionFront panel installation, horizontal
Accessories

Why Proax for Phoenix Contact 2901366?

Proax is an authorized distributor of Phoenix Contact 2901366 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability