Official Distributor
SKU
MPN
EEM-MA600
Weight
0.822 kg
Series EEM-MA
EEM-MA600 - Measuring instrument
Energy measurement device to measure electrical parameters in low voltage installations up to 700 V, acquisition of individual harmonic oscillations - can be extended with communication and special functional modules
- Can be extended with special function and communication modules
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Electrical properties
Electrical isolation | EN 61010-1 (Safe isolation) |
Electrical isolation | See extension module |
Electrical isolation | See extension module |
Test voltage | 3.5 kV AC (50 Hz, 1 min.) |
Maximum power dissipation for nominal condition | 10 VA |
Mains type | 3-phase (3 or 4-conductor), 2-phase (2-conductor), and single-phase (1-conductor) |
Electrical isolation
Overvoltage category | III (For mains voltage <300 V AC (L/N)) |
Overvoltage category | II (for mains voltage >300 V AC ... 600 V AC (L/N)) |
Pollution degree | 2 |
Supply
Supply Voltage | 230 V AC |
Supply Voltage | 400 V AC |
Supply Voltage Range | 110 V AC ... 400 V AC ±10 % |
Supply Voltage Range | 120 V DC ... 350 V DC (±20 %) |
Nominal Power Consumption | 10 VA |
Power consumption | 20 VA (with max. number of extension modules) |
General
Measuring Principle | True r.m.s. value measurement |
Measured value | AC sine (50 Hz/60 Hz) |
Acquisition of harmonics | up to 63rd harmonic |
Voltage input signal | Via function module |
Measurement: Voltage
Input name | Voltage measuring input V1, V2, V3 |
Input Voltage | 500 kV AC (Primary, via external voltage transducers) |
Input Voltage | Secondary: 60, 100, 110, 115, 120, 173, 190 V AC |
Input voltage range | 18 V AC ... 700 V AC (Phase/Phase) |
Input voltage range | 11 V AC ... 404 V AC (Phase/neutral conductor) |
Precision | 0.2 % |
Measurement: Current
Input name | Current measurement I1, I2, I3 |
Input current range | via external transformers |
Input Current | 9999 A (primary) |
Input Current | 1 A and 5 A, secondary |
Measuring Range | 0 A ... 9999 A |
Overload capacity | 6 A (Permanent) |
Response threshold from measuring range nominal value | 10 mA |
Precision | 0.2 % |
Current overload | 10 x IN for 1 s |
Measurement: Power
Messbereich_Leistung | 0 MW ... 8000 MW |
Messbereich_Leistung | 0 Mvar ... 8000 Mvar |
Messbereich_Leistung | 0 MVA ... 8000 MVA |
Precision | 0.5 % |
Active energy (IEC 62053-22) | Class 0.5 S |
Reactive power (IEC 62053-23) | Class 2 |
Output data
Output description | Via function module |
Connection data
Connection Method | COMBICON plug-in screw terminal block |
Note | Connections for current, voltage, and supply |
Conductor cross section rigid | 0.2 mm² ... 6 mm² |
Conductor cross section flexible | 0.2 mm² ... 4 mm² |
Connection Method | Screw connection |
Note | Connections for digital I/O and communication |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
Dimensions
Width | 96 mm |
Height | 96 mm |
Depth | 82 mm |
Depth | 80 mm (Installation depth with extension module) |
Depth | 60 mm (Installation depth without extension module) |
Material specifications
Color | black (RAL 9005) |
Ambient conditions
Degree of Protection | IP52 (Front) |
Degree of Protection | IP30 (On the rear) |
Ambient Temperature (Operation) | -10 °C ... 55 °C (14 °F ... 131 °F) |
Ambient temperature (storage/transport) | -20 °C ... 85 °C (-4 °F ... 185 °F) |
Max. permissible relative humidity (operation) | ≤ 95 % |
Max. salt spray content | ≤ 2.5 % |
CE
Certificate | CE-compliant |
UL, USA/Canada
Identification | UL 61010-1 |
Identification | CSA-C22.2 No. 61010-1 |
Identification | cULus |
UL data
Nominal supply voltage range | 110 V AC ... 240 V AC ±10 % |
Nominal supply voltage range | 120 V DC ... 250 V DC ±10 % |
Power consumption | 10 VA |
Altitude | ≤ 2000 m |
Operating mode | Indoor use |
Surge voltages | Transient overvoltage according to installation classes |
Overvoltage category | I, II, III |
Overvoltage category of the supply | Min. II |
Ambient Temperature (Operation) | 0 °C ... 40 °C |
Max. permissible relative humidity (operation) | 80 % (up to 31 °C) |
Max. permissible relative humidity (operation) | 50 % (at 40 °C) |
Nominal supply voltage range | 110 V AC ... 240 V AC ±10 % |
Nominal supply voltage range | 120 V DC ... 250 V DC ±10 % |
Power consumption | 10 VA |
Altitude | ≤ 2000 m |
Operating mode | Indoor use |
Ambient Temperature (Operation) | 0 °C ... 40 °C |
Max. permissible relative humidity (operation) | 80 % (up to 31 °C) |
Max. permissible relative humidity (operation) | 50 % (at 40 °C) |
Surge voltages | Transient overvoltage according to installation classes |
Overvoltage category | I, II, III |
Overvoltage category of the supply | Min. II |
Mounting
Mounting Position | Front panel installation, horizontal |
Accessories
Why Proax for Phoenix Contact 2901366?
Proax is an authorized distributor of Phoenix Contact 2901366 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended