Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Electrical properties
Electrical isolation | EN 61010-1 (Safe isolation) |
Electrical isolation | EN 61010-1 (Safe isolation) |
Electrical isolation | EN 61010-1 (Safe isolation) |
Electrical isolation | EN 61010-1 (Safe isolation) |
Electrical isolation | EN 61010-1 (Safe isolation) |
Electrical isolation | EN 61010-1 (Safe isolation) |
Electrical isolation | EN 61010-1 (Safe isolation) |
Electrical isolation | EN 61010-1 (Basic insulation) |
Electrical isolation | EN 61010-1 (Basic insulation) |
Electrical isolation | EN 61010-1 (Basic insulation) |
Test voltage | 3.5 kV AC (50 Hz, 1 min.) |
Test voltage | 2.2 kV AC (50 Hz, 1 min.) |
Mains type | 3-phase (3 or 4-conductor), 2-phase (2-conductor), and single-phase (1-conductor) |
Electrical isolation
Rated Insulation Voltage | 300 V AC (EN 61010-1) |
Overvoltage category | III |
Pollution degree | 2 |
Supply
Supply Voltage Range | 110 V AC ... 277 V AC -10 % ... +15 % |
Nominal Power Consumption | 5 VA |
General
Measuring Principle | True r.m.s. value measurement |
Measured value | AC sinus (45 ... 65 Hz) |
Acquisition of harmonics | up to 51st harmonic |
Description of the input | Digital input |
Number | 1 |
Voltage input signal | 230 V AC ±10 % (Tariff switchover: e.g., day/nighttime tariff) |
Measurement: Voltage
Input name | Voltage measurement V1, V2, V3 |
Input voltage range | 50 V AC ... 519 V AC (Phase/Phase) |
Input voltage range | 28 V AC ... 300 V AC (Phase/neutral conductor) |
Precision | 0.2 % |
Measurement: Current
Input name | Current measurement I1, I2, I3 |
Input current range | via external transformers |
Input Current | 9999 A (primary) |
Input Current | 5 A (secondary) |
Overload capacity | 6 A (Permanent) |
Response threshold from measuring range nominal value | 5 mA |
Precision | 0.2 % |
Measurement: Power
Messbereich_Leistung | 0 kW ... 9999 kW |
Messbereich_Leistung | 0 kvar ... 9999 kvar |
Messbereich_Leistung | 0 kVA ... 9999 kVA |
Precision | 0.5 % |
Active energy (IEC 62053-22) | Class 0.5 S |
Reactive power (IEC 62053-23) | Class 2 |
Output data
Output description | Transistor output, active |
Number | 1 |
Maximum Switching Voltage | 30 V DC |
Current carrying capacity | 27 mA |
Connection data
Connection Method | Screw connection |
Note | other connections |
Conductor cross section rigid | 0.5 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.5 mm² ... 2.5 mm² |
Conductor cross section AWG | 20 ... 14 |
Note | Current and voltage connection |
Conductor cross section rigid | 0.5 mm² ... 4 mm² |
Conductor cross section flexible | 0.5 mm² ... 4 mm² |
Conductor cross section AWG | 20 ... 10 |
Dimensions
Width | 72 mm |
Height | 90 mm |
Depth | 64 mm |
Material specifications
Color | black (RAL 9005) |
Ambient conditions
Degree of Protection | IP51 (Front) |
Degree of Protection | IP20 (Back side) |
Ambient Temperature (Operation) | -10 °C ... 55 °C (14 °F ... 131 °F) |
Ambient temperature (storage/transport) | -20 °C ... 70 °C (-4 °F ... 158 °F) |
Max. permissible relative humidity (operation) | ≤ 95 % |
Max. salt spray content | ≤ 2.5 % |
CE
Certificate | CE-compliant |
UL, USA/Canada
Identification | UL 61010-1 |
Identification | CSA-C22.2 No. 61010-1 |
Identification | cULus |
UL data
Nominal supply voltage range | 110 V AC ... 277 V AC -10 % ... +15 % |
Altitude | ≤ 2000 m |
Operating mode | Indoor use |
Surge voltages | Transient overvoltage according to installation classes |
Overvoltage category | I, II, III |
Overvoltage category of the supply | Min. II |
Ambient Temperature (Operation) | 5 °C ... 40 °C |
Max. permissible relative humidity (operation) | 80 % (up to 31 °C) |
Max. permissible relative humidity (operation) | 50 % (at 40 °C) |
Nominal supply voltage range | 110 V AC ... 277 V AC -10 % ... +15 % |
Altitude | ≤ 2000 m |
Operating mode | Indoor use |
Ambient Temperature (Operation) | 5 °C ... 40 °C |
Max. permissible relative humidity (operation) | 80 % (up to 31 °C) |
Max. permissible relative humidity (operation) | 50 % (at 40 °C) |
Surge voltages | Transient overvoltage according to installation classes |
Overvoltage category | I, II, III |
Overvoltage category of the supply | Min. II |
Mounting
Mounting Type | DIN rail mounting |
Mounting Position | Horizontal DIN rail |
Why Proax for Phoenix Contact 2901362?
Proax is an authorized distributor of Phoenix Contact 2901362 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended