Series EEM-MA
EEM-MA400 - Measuring instrument
Energy measurement device to measure electrical parameters in low voltage installations up to 500 V, acquisition of total harmonic oscillations - can be extended with RS-485 communication module
- Can be extended with RS-485 communication module (JBUS/MODBUS)
- Acquisition of total harmonics up to 51st harmonic
Technical Specifications
Utilization restriction
EMC note | EMC: class A product, see manufacturer's declaration in the download area |
Electrical properties
Electrical isolation | EN 61010-1 (Safe isolation) |
Electrical isolation | EN 61010-1 (Safe isolation) |
Electrical isolation | EN 61010-1 (Basic insulation) |
Electrical isolation | See extension module |
Electrical isolation | See extension module |
Electrical isolation | See extension module |
Test voltage | 3.5 kV AC (50 Hz, 1 min.) |
Test voltage | 2.2 kV AC (50 Hz, 1 min.) |
Mains type | 3-phase (3 or 4-conductor), 2-phase (2-conductor), and single-phase (1-conductor) |
Electrical isolation
Rated Insulation Voltage | 300 V AC (EN 61010-1) |
Overvoltage category | III |
Pollution degree | 2 |
Supply
Supply Voltage Range | 110 V AC ... 400 V AC ±10 % |
Supply Voltage Range | 120 V DC ... 350 V DC (±20 %) |
Nominal Power Consumption | 5 VA |
Power consumption | 10 VA (with max. number of extension modules) |
General
Measuring Principle | True r.m.s. value measurement |
Measured value | AC sine (50 Hz/60 Hz) |
Acquisition of harmonics | up to 51st harmonic |
Measurement: Voltage
Input name | Voltage measuring input V1, V2, V3 |
Input voltage range | 50 V AC ... 500 V AC (Phase/Phase) |
Input voltage range | 28 V AC ... 289 V AC (Phase/neutral conductor) |
Precision | 0.2 % |
Measurement: Current
Input name | Current measurement I1, I2, I3 |
Input current range | via external transformers |
Input Current | 9999 A (primary) |
Input Current | 5 A (secondary) |
Measuring Range | 0 A ... 9999 A |
Overload capacity | 6 A (Permanent) |
Response threshold from measuring range nominal value | 5 mA |
Precision | 0.2 % |
Current overload | 10 x IN for 1 s |
Measurement: Power
Messbereich_Leistung | 0 MW ... 11 MW |
Messbereich_Leistung | 0 Mvar ... 11 Mvar |
Messbereich_Leistung | 0 MVA ... 11 MVA |
Precision | 0.5 % |
Active energy (IEC 62053-22) | Class 0.5 S |
Reactive power (IEC 62053-23) | Class 2 |
Output data
Output description | Via function module |
Connection data
Connection Method | COMBICON plug-in screw terminal block |
Stripping length | 6 mm |
Note | Voltage and other connections |
Conductor cross section rigid | 0.5 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.5 mm² ... 2.5 mm² |
Conductor cross section AWG | 20 ... 14 |
Tightening torque | 0.4 Nm ... 0.4 Nm |
Connection Method | Screw connection |
Stripping length | 7 mm |
Note | Current connection |
Conductor cross section rigid | 0.5 mm² ... 6 mm² |
Conductor cross section flexible | 0.5 mm² ... 6 mm² |
Conductor cross section AWG | 20 ... 8 |
Dimensions
Width | 96 mm |
Height | 96 mm |
Depth | 82 mm |
Depth | 80 mm (Installation depth with extension module) |
Depth | 60 mm (Installation depth without extension module) |
Material specifications
Color | black (RAL 9005) |
Ambient conditions
Degree of Protection | IP52 (Front) |
Degree of Protection | IP30 (Back side) |
Ambient Temperature (Operation) | -10 °C ... 55 °C (14 °F ... 131 °F) |
Ambient temperature (storage/transport) | -20 °C ... 85 °C (-4 °F ... 185 °F) |
Max. permissible relative humidity (operation) | ≤ 95 % |
Max. salt spray content | ≤ 2.5 % |
CE
Certificate | CE-compliant |
UL, USA/Canada
Identification | UL 61010-1 |
Identification | CSA-C22.2 No. 61010-1 |
Identification | cULus |
UL data
Supply Voltage | 300 V AC |
Nominal supply voltage range | 110 V AC ... 240 V AC ±10 % |
Nominal supply voltage range | 120 V DC ... 250 V DC ±10 % |
Power consumption | 10 VA |
Altitude | ≤ 2000 m |
Operating mode | Indoor use |
Surge voltages | Transient overvoltage according to installation classes |
Overvoltage category | I, II, III |
Overvoltage category of the supply | Min. II |
Ambient Temperature (Operation) | 0 °C ... 40 °C |
Max. permissible relative humidity (operation) | 80 % (up to 31 °C) |
Max. permissible relative humidity (operation) | 50 % (at 40 °C) |
Supply Voltage | 300 V AC |
Nominal supply voltage range | 110 V AC ... 240 V AC ±10 % |
Nominal supply voltage range | 120 V DC ... 250 V DC ±10 % |
Power consumption | 10 VA |
Altitude | ≤ 2000 m |
Operating mode | Indoor use |
Ambient Temperature (Operation) | 0 °C ... 40 °C |
Max. permissible relative humidity (operation) | 80 % (up to 31 °C) |
Max. permissible relative humidity (operation) | 50 % (at 40 °C) |
Surge voltages | Transient overvoltage according to installation classes |
Overvoltage category | I, II, III |
Overvoltage category of the supply | Min. II |
Mounting
Mounting Position | Front panel installation, horizontal |
Accessories
Why Proax for Phoenix Contact 2901364?
Proax is an authorized distributor of Phoenix Contact 2901364 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended