Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
FLT-SEC-T1+T2-1C-350/25-FM
Weight
0.35 kg
Series FLT-SEC-T

FLT-SEC-T1+T2-1C-350/25-FM - Type 1+2 special combined lightning current and surge arrester

Plug-in lightning and surge arrester combination, in accordance with Type 1+2/Class I+II, for 1-phase power supply networks, with combined PE and N installed in one conductor (L1, PEN).

  • Surge protection family for universal use with optimum energy coordination from the lightning current arrester to the device protection
  • Easy to maintain due to consistently pluggable protection modules
  • Excellent level of information provided by mechanical/visual status indicator and remote indication contact
  • Optimum protective effect in the event of high-energy lightning currents, thanks to spark gap technology with low residual voltage characteristic
  • Maximum protection against dynamic overvoltages for sensitive devices, thanks to direct coordination with varistor arresters connected in parallel
Technical Specifications

Product properties

Product familySEC Family
IEC test classificationI + II
IEC test classificationI
IEC test classificationT1 + T2
IEC test classificationT1
EN typeT1 + T2
EN typeT1
IEC power supply systemTN-C
IEC power supply systemTT
TypeDIN rail module, two-section, divisible
Number of Positions1
Surge protection fault messageOptical, remote indicator contact

Insulation characteristics

Overvoltage categoryIII
Pollution degree2

Electrical properties

Nominal frequency fN50 Hz (60 Hz)

Indicator/remote signaling

Connection nameRemote fault indicator contact
Switching functionChangeover contact
Operating Voltage12 V AC ... 250 V AC
Operating Voltage125 V DC (200 mA DC)
Operating current10 mA AC ... 1 A AC
Operating current1 A DC (30 V DC)

Connection data

Connection MethodScrew connection
Screw threadM5
Tightening torque4.5 Nm
Stripping length18 mm
Conductor cross section flexible2.5 mm² ... 35 mm²
Conductor cross section rigid2.5 mm² ... 35 mm²
Conductor cross section AWG13 ... 2
Connection MethodFork-type cable lug
Conductor cross section flexible1.5 mm² ... 16 mm²

Remote fault indicator contact

Connection MethodPlug-in/screw connection via COMBICON
Screw threadM2
Tightening torque0.25 Nm
Stripping length7 mm
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16

Dimensions

Width35.6 mm
Height95.2 mm
Depth74.5 mm
Horizontal pitch2 Div.

Material specifications

Color (Male connector)light grey (RAL 7035)
Color (Base element)gray (RAL 7042)
Flammability rating according to UL 94V-0
CTI value of material600
Insulating materialPA6.6-FR 20% GF
Insulating materialPBT-FR
Material groupI
Housing MaterialPA 6.6-FR 20 % GF
Housing MaterialPBT-FR

Mechanical data

Open side panelNo

Protective circuit

Mode of protectionL-PEN
Direction of action1L-N/PE
Nominal voltage UN240 V AC (TN-C)
Nominal voltage UN240 V AC (TT)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC350 V AC
Rated load current IL125 A (< 55 °C)
Nominal discharge current In (8/20) µs25 kA
Impulse discharge current (10/350) µs, charge12.5 As
Impulse discharge current (10/350) µs, specific energy160 kJ/Ω
Impulse discharge current (10/350) µs, peak value limp25 kA
Follow current interrupt rating Ifi25 kA (264 V AC)
Follow current interrupt rating Ifi3 kA (350 V AC)
Short-circuit current rating ISCCR25 kA (264 V AC)
Short-circuit current rating ISCCR3 kA (350 V AC)
Voltage protection level Up≤ 1.5 kV
Residual voltage Ures≤ 1.5 kV (at In)
Residual voltage Ures≤ 1.2 kV (at 10 kA)
Residual voltage Ures≤ 1 kV (at 5 kA)
Residual voltage Ures≤ 0.9 kV (at 3 kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs≤ 1.5 kV
TOV behavior at UT415 V AC (5 s / withstand mode)
TOV behavior at UT457 V AC (120 min / safe failure mode)
Response time tA≤ 25 ns
Max. backup fuse with V-type through wiring125 A (gG)
Max. backup fuse with branch wiring315 A (gG)

Additional technical data

Maximum discharge current Imax (8/20) µs100 kA

Ambient conditions

Degree of ProtectionIP20 (only when all terminal points are used)
Ambient Temperature (Operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl)
Permissible humidity (operation)5 % ... 95 %
Shock (operation)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (Operation)5g (5 - 500 Hz/2.5 h/X, Y, Z)

UL specifications

Maximum continuous operating voltage MCOV264 V AC
Short-circuit current rating (SCCR)50 kA
Voltage protection rating VPR1200 V
Nominal discharge current In20 kA
Mode of protectionL-G
Nominal Voltage240 V AC
Rated load current IL50 A
Power distribution systemSingle phase
Nominal frequency50/60 Hz
SPD Type2CA

UL indicator/remote signaling

Operating Voltage125 V AC
AC operating current1 A AC

UL connection data

Tightening torque40 lbf-in.
Conductor cross section AWG3 ... 2

Standards and Regulations

Standards/specificationsIEC 61643-11
Note2011

EN 61643-11

Standards/specificationsEN 61643-11
Note2012

Mounting

Mounting TypeDIN rail: 35 mm
Accessories

Why Proax for Phoenix Contact 2905465?

Proax is an authorized distributor of Phoenix Contact 2905465 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability