Official Distributor
SKU
MPN
IBS IL 24 BK DIO 16/16/SN
Weight
0.71 kg
Series IBS-IL
IBS IL 24 BK DIO 16/16/SN - Bus coupler
INTERBUS bus coupler, 16 inputs, 24 V DC, 16 outputs, 24 V DC, 500 mA, with non-numbered connectors
- Maximum permissible load current per sensor: 250 mA
- 16 digital inputs
- Diagnostic and status indicators
- Nominal current per output: 500 mA
- 16 digital outputs
- Connection of sensors in 2- and 3-conductor technology
- Connection of actuators in 2- and 3-conductor technology
Technical Specifications
Dimensions
Width | 146.4 mm |
Height | 140.5 mm |
Depth | 71.5 mm |
Material specifications
Color | green |
INTERBUS
No. of channels | 2 |
Connection Method | Inline shield connector |
Number of Positions | 6 |
Transmission Speed | 500 kbps |
Transmission physics | Copper |
Inline local bus
Connection Method | Inline data jumper |
Transmission Speed | 500 kbps |
System limits
Number of local bus devices that can be connected | 63 (observe total permissible current consumption) |
Number of supported branch terminals with remote bus branch | max. 15 |
Module
ID code (hex) | 4 |
Register length | 32 bit |
Digital:
Input name | Digital inputs |
Description of the input | EN 61131-2 type 1 |
Number of Inputs | max. 16 |
Connection Method | Spring-cage connection |
Input Voltage | 24 V DC |
Output name | Digital outputs |
Connection Method | Spring-cage connection |
Connection technology | 2-, 3-conductor |
Number of Outputs | 16 |
Output Voltage | 24 V DC |
Product properties
Product family | Inline |
Type | modular |
No. of channels | 32 |
Electrical properties
Maximum power dissipation for nominal condition | 12 W |
Protective circuit | Reverse polarity protection |
Supply Voltage | 24 V DC (via Inline connector) |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 1.25 A (with max. number of connected I/O terminal blocks (24 V DC supply)) |
Current draw | typ. 100 mA (without connected Inline I/O terminals) |
Potentials: Communications power (UL)
Supply Voltage | 7.5 V DC ±5 % |
Potentials: Supply of analog modules (UANA)
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Potentials: Main circuit supply (UM)
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Potentials: Segment circuit supply (US)
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Electrical isolation/isolation of the voltage ranges
Test voltage: 5 V supply, incoming remote bus / 5 V supply outgoing remote bus | 500 V AC, 50 Hz, 1 min. |
Test voltage: 5 V supply incoming remote bus / 7.5 V communications power, 24 V analog supply, 24 V bus coupler supply | 500 V AC, 50 Hz, 1 min. |
Test voltage: 5 V supply, incoming remote bus / 24 V main supply, 24 V segment supply | 500 V AC, 50 Hz, 1 min. |
Test voltage: 5 V supply incoming remote bus / functional ground | 500 V AC, 50 Hz, 1 min. |
Test voltage: 5 V supply outgoing remote bus / communications power (UBK, UL, UANA) | 500 V AC, 50 Hz, 1 min. |
Test voltage: 5 V supply outgoing remote bus / I/O (UM, US) | 500 V AC, 50 Hz, 1 min. |
Test voltage: 5 V supply outgoing remote bus / functional ground | 500 V AC, 50 Hz, 1 min. |
Test voltage: 7.5 V communications power, 24 V analog supply, 24 V bus coupler supply/functional ground | 500 V AC, 50 Hz, 1 min. |
Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply / 24 V main supply, 24 V segment supply | 500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V main supply, 24 V segment supply/functional ground | 500 V AC, 50 Hz, 1 min. |
Connection technology
Connection name | Inline connector |
Conductor connection
Connection Method | Spring-cage connection |
Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm |
Inline connector
Connection Method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 55 °C |
Degree of Protection | IP20 |
Air pressure (operation) | 80 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Permissible humidity (operation) | 95 % (non-condensing) |
Permissible humidity (storage/transport) | 95 % (non-condensing) |
Mounting
Mounting Type | DIN rail mounting |
Why Proax for Phoenix Contact 2863669?
Proax is an authorized distributor of Phoenix Contact 2863669 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- 2742586 - Inline, Bus coupler, INTERBUS, Inline shield connector, Digital inputs: 16, 24 V DC, connection technology: 3-conductor, Digital outputs: 16, 24 V DC, 500 mA, connection technology: 3-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connectors and marking fields