Series IBS-IL

IBS IL 24 BK DIO 16/16 - Bus coupler

Inline, Bus coupler, INTERBUS, Inline shield connector, Digital inputs: 16, 24 V DC, connection technology: 3-conductor, Digital outputs: 16, 24 V DC, 500 mA, connection technology: 3-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connectors and marking fields

  • 16 digital inputs
  • 16 digital outputs
  • Connection of sensors in 2- and 3-conductor technology
  • Connection of actuators in 2- and 3-conductor technology
  • Maximum permissible load current per sensor: 250 mA
  • Nominal current per output: 500 mA
  • Diagnostic and status indicators
Technical Specifications

Dimensions

Width146.4 mm
Height140.5 mm
Depth71.5 mm

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

INTERBUS

Number of interfaces2
Connection MethodInline shield connector
Transmission Speed500 kbps

Inline local bus

Number of interfaces1
Connection MethodInline data jumper
Transmission Speed500 kbps

System limits

Number of local bus devices that can be connected63 (observe total permissible current consumption)
Number of devices with parameter channel16
Number of supported branch terminals with remote bus branchmax. 15

Module

ID code (hex)4
Register length32 bit

Digital:

Input nameDigital inputs
Description of the inputEN 61131-2 type 1
Number of Inputs16
Connection MethodSpring-cage connection
Connection technology3-conductor
Input Voltage24 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Nominal input voltage UIN24 V DC
Typical input current per channeltyp. 3 mA
Protective circuitPolarity reversal; Suppressor diode
Output nameDigital outputs
Connection MethodSpring-cage connection
Connection technology3-conductor
Number of Outputs16
Protective circuitShort-circuit and overload protection; Free running circuit
Output Voltage24 V DC -1 V (At nominal current)
Maximum Output Current per modulemax. 8 A
Nominal Output Voltage24 V DC
Nominal load, inductive12 VA
Nominal load, lamp12 W
Nominal load, ohmic12 W

Product properties

Product familyInline
Typemodular
Scope of deliveryincluding Inline connectors and marking fields
No. of channels32

Electrical properties

Maximum power dissipation for nominal condition30 W
Protective circuitReverse polarity protection

Supply Voltage24 V DC (via Inline connector)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 1.25 A (with max. number of connected I/O terminal blocks (24 V DC supply))
Current drawtyp. 100 mA (without connected Inline I/O terminals)

Potentials: Communications power (UL)

Supply Voltage7.5 V DC ±5 %

Potentials: Supply of analog modules (UANA)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)

Potentials: Main circuit supply (UM)

Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)

Potentials: Segment circuit supply (US)

Supply Voltage24 V DC (via voltage jumper)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply, incoming remote bus / 5 V supply outgoing remote bus500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply incoming remote bus / 7.5 V communications power, 24 V analog supply, 24 V bus coupler supply500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, incoming remote bus / 24 V main supply, 24 V segment supply500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply incoming remote bus / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply outgoing remote bus / communications power (UBK, UL, UANA)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply outgoing remote bus / I/O (UM, US)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply outgoing remote bus / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V communications power, 24 V analog supply, 24 V bus coupler supply/functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply / 24 V main supply, 24 V segment supply500 V AC, 50 Hz, 1 min.
Test voltage: 24 V main supply, 24 V segment supply/functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameInline connector

Conductor connection

Connection MethodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Inline connector

Connection MethodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 55 °C
Degree of ProtectionIP20
Air pressure (operation)80 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation)95 % (non-condensing)
Permissible humidity (storage/transport)95 % (non-condensing)

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2742586?

Proax is an authorized distributor of Phoenix Contact 2742586 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability