Official Distributor
SKU
MPN
VS-OE-M12FSBP-93C-LI/2,0
Weight
0.166 kg
Series VS-OE-M
VS-OE-M12FSBP-93C-LI/2,0 - Device connector rear mounting
Device connector rear mounting, PROFINET CAT5 (100 Mbps), EtherCAT® CAT5 (100 Mbps), 4-position halogen-free, green RAL 6018, shielded, Socket, straight, M12, coding: D, on free cable end, Rear mounting, Cable lug connection, cable length: 2 m, Alternative product in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) item no.: 1239110
- Preassembled with cables in various standard lengths for immediate use
- Customer-specific assemblies and cable lengths can be supplied
- Sealed on the cable side for optimum tightness of seal
- Cable designs for all common networks and fieldbuses
- For high transmission safety: shield connection to the housing with optional EMC nut
Technical Specifications
Notes
Notes on operation | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
Safety note
Safety note | WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. |
Safety note | • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. |
Safety note | • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. |
Safety note | • The products are suitable for applications in plant, controller, and electrical device engineering. |
Safety note | • When operating the connectors in outdoor applications, they must be separately protected against environmental influences. |
Safety note | • Assembled products may not be manipulated or improperly opened. |
Safety note | • Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products). |
Safety note | • When using the product in direct connection with third-party manufacturers, the user is responsible. |
Safety note | • For operating voltages > 50 V AC, conductive connector housings must be grounded |
Safety note | • Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards. |
Safety note | • Observe the corresponding technical data. You will find information:o On the producto On the packing labelo In the supplied documentationo Online at phoenixcontact.com/products under the product |
Safety note | • Only use tools recommended by Phoenix Contact |
Safety note | • Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products |
Safety note | • Ensure that the protective or functional ground has been properly connected. |
Safety note | • VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector |
Safety note | • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). |
Product properties
Application | Data |
Sensor Type | PROFINET |
Number of Positions | 4 |
No. of cable outlets | 1 |
Shielded | yes |
Coding | D |
Insulation characteristics
Overvoltage category | II |
Degree of pollution | 3 |
Interfaces
Bus system | PROFINET |
Signal type/category | PROFINET CAT5 (IEC 11801:2002), 100 Mbps |
Signal type/category | EtherCAT® CAT5 (IEC 11801), 100 Mbps |
Electrical properties
Rated surge voltage | 2.5 kV |
Contact resistance | ≤ 3 mΩ |
Insulation resistance | ≥ 100 MΩ |
Nominal voltage UN | 250 V |
Nominal current IN | 4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed) |
Transmission medium | Copper |
Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
Mechanical data
Insertion/withdrawal cycles | ≥ 100 |
Material specifications
Flammability rating according to UL 94 | V0 |
Seal material | FKM |
Contact Material | CuZn |
Contact surface material | Ni/Au |
Contact carrier material | PA 6.6 |
Material for screw connection | Brass, nickel-plated |
Connection technology
Connection Method | Cable lug connection |
Conductor connection
Contact connection type | Socket |
Connection Method | Cable lug connection |
Tightening torque | 2 Nm ... 3 Nm (Installation-side) |
Connection 1
Head design | Socket |
Head cable outlet | straight |
Head thread type | M12 |
Coding | D |
Connection 2
Head design | free cable end |
Cable/line
Cable Length | 2 m |
PROFINET drag chain CAT5 [93C]
Cable weight | 61 kg/km |
Number of Positions | 4 |
Shielded | yes |
Cable Type | PROFINET drag chain CAT5 [93C] |
Conductor structure | 1x4xAWG22/7, SF/TQ |
Signal runtime | 5.3 ns/m |
Signal speed | 0.66 c |
Conductor structure signal line | 7x 0.25 mm |
AWG Signal Line | 22 |
Conductor Cross Section | 4x 0.34 mm² |
Wire diameter incl. insulation | 1.5 mm |
External Cable Diameter | 6.50 mm ±0.2 mm |
Outer sheath, material | PUR |
External sheath, color | green RAL 6018 |
Conductor material | Tin-plated Cu litz wires |
Material wire insulation | PE |
Single wire, color | white, yellow, blue, orange |
Thickness, outer sheath | approx. 0.90 mm |
Overall twist | Star quad |
Optical shield covering | 85 % |
Insulation resistance | ≥ 500 MΩ*km |
Coupling resistance | ≤ 20.00 mΩ/m (at 10 MHz) |
Loop resistance | ≤ 120.00 Ω/km |
Wave impedance | 100 Ω ±15 Ω (at 1 ... 100 MHz) |
Nominal voltage, cable | 600 V (UL rating) |
Test voltage Core/Core | 2000 V (50 Hz, 1 min.) |
Test voltage Core/Shield | 2000.00 V (50 Hz, 1 min.) |
Minimum bending radius, fixed installation | 5 x D |
Minimum bending radius, flexible installation | 7.5 x D |
Smallest bending radius, fixed installation | 33 mm |
Smallest bending radius, movable installation | 49 mm |
Max. bending cycles | 3000000 |
Tensile strength | ≤ 150 N |
Torsion force | ± 30 °/m |
Near end crosstalk attenuation (NEXT) | 80 dB (with 1 MHz) |
Near end crosstalk attenuation (NEXT) | 76 dB (at 4 МHz) |
Near end crosstalk attenuation (NEXT) | 70 dB (at 10 MHz) |
Near end crosstalk attenuation (NEXT) | 65 dB (at 16 MHz) |
Near end crosstalk attenuation (NEXT) | 63 dB (at 20 МHz) |
Near end crosstalk attenuation (NEXT) | 60 dB (at 31.25 МHz) |
Near end crosstalk attenuation (NEXT) | 55 dB (at 62.5 МHz) |
Near end crosstalk attenuation (NEXT) | 50 dB (at 100 MHz) |
Shield attenuation | 2.1 dB (with 1 MHz) |
Shield attenuation | 4 dB (at 4 МHz) |
Shield attenuation | 6.3 dB (at 10 MHz) |
Shield attenuation | 8 dB (at 16 MHz) |
Shield attenuation | 9 dB (at 20 МHz) |
Shield attenuation | 11.4 dB (at 31.25 МHz) |
Shield attenuation | 16.5 dB (at 62.5 МHz) |
Shield attenuation | 21.3 dB (at 100 MHz) |
Halogen-free | yes |
Flame resistance | according to IEC 60332-1-2 |
Resistance to Oil | in accordance with DIN EN 60811-2-1 |
Other resistance | UV resistant |
Special Properties | Electrical properties in accordance with EN 50288-2-2 |
Ambient Temperature (Operation) | -40 °C ... 70 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -40 °C ... 70 °C (Cable, flexible installation) |
Ambient temperature (installation) | -20 °C ... 60 °C |
Ambient conditions
Degree of Protection | IP67 (When plugged in) |
Degree of Protection | IP65 (When plugged in) |
Degree of Protection | IP65/IP67 |
Ambient Temperature (Operation) | -25 °C ... 85 °C (Plug / socket) |
Ambient Temperature (Operation) | -40 °C ... 85 °C (without mechanical actuation) |
M12
Standard designation | M12 connector |
Standards/specifications | IEC 61076-2-101 |
Accessories
Why Proax for Phoenix Contact 1416209?
Proax is an authorized distributor of Phoenix Contact 1416209 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended