Official Distributor
SKU
MPN
CBMC EG4 24DC/1-8A NO
Weight
0.182 kg
CBMC EG4 24DC/1-8A NO - Electronic circuit breaker
Multi-channel electronic circuit breaker with electrical isolation for protecting four loads at 24 V DC in the event of overload or short circuit. With electronic locking of the set nominal currents. For installation on DIN rails.
- Easy device replacement without replanning, thanks to compact design and options for individual adjustments
- Circuits can be adjusted without any tools by means of one single pushable LED button
- System safety is increased during maintenance work thanks to disconnection via electrical isolation
- Safe system operation, thanks to patented monitoring of electrical isolation
- Reliable protection against unintentional adjustment of current values, thanks to electronic locking
- Status LEDs in traffic light colors enable instantaneous determination of operating states
Technical Specifications
General
Note | Repeated hard short circuits can reduce the melting integral of the integrated backup fuse. |
Product properties
Product family | CBMC |
Type | DIN rail module, one-piece |
Number of Positions | 1 |
No. of channels | 4 |
Insulation characteristics
Protection class | III |
Pollution degree | 2 |
General
Operating Voltage | 18 V DC ... 30 V DC |
Rated voltage | 24 V DC |
Rated current IN | max. 32 A DC (IN+) |
Rated current IN | max. 40 A DC (per terminal position when bridging additional devices via IN+) |
Rated current IN | 1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 A DC (adjustable per output channel) |
Rated current (pre-adjusted) | 4 A |
Rated surge voltage | 0.5 kV |
Tripping method | EG (electronic - galvanic disconnection) |
Feedback resistance | max. 35 V DC |
Required backup fuse | Only required if Imax of the power supply > the short-circuit switching capacity. Integrated failsafe element. |
Required backup fuse | 30 A (gG, supplied with linear power supply, Icn ≥ 200 A) |
Short-circuit switching capacity | 300 A |
Dielectric strength | max. 35 V DC (Load circuit) |
Fuse | electronic |
Efficiency | > 99 % |
Closed circuit current I0 | typ. 75 mA |
Power dissipation | typ. 1.8 W (No-load operation) |
Power dissipation | < 7 W (Nominal operation) |
Module initialization time | 1.6 s |
Waiting time after switch off of a channel | 5 s (at overload / short circuit) |
Measuring tolerance I | ± 15 % |
Temperature derating | 25 A DC (at 60 °C) |
Temperature derating | 28 A DC (at 56 °C) |
Temperature derating | 32 A DC (at 52 °C) |
MTBF (IEC 61709, SN 29500) | 5000000 h (at 25 °C with 21 % load) |
MTBF (IEC 61709, SN 29500) | 2000000 h (at 40°C with 34.25% load) |
MTBF (IEC 61709, SN 29500) | 321056 h (at 52°C with 100% load) |
Fail-safe element | 15 A DC (per output channel) |
Load circuit
Shutdown time | ≤ 10 ms (for short circuit > 2.0 x IN) |
Shutdown time | 1 s (1.2 ... 2.0 x IN) |
Undervoltage switch-off | ≤ 17.8 V DC (active) |
Undervoltage switch-off | ≥ 18.8 V DC (inactive) |
Overvoltage switch-off | ≥ 30.5 V DC (active) |
Overvoltage switch-off | ≤ 29.5 V DC (inactive) |
Max. capacitive load | 45000 µF (Depending on the current setting and the short-circuit current available) |
Indicator/remote signaling
Connection name | Remote indication circuit |
Switching function | N/O contact |
Operating Voltage | 0 V DC ... 30 V DC |
Operating current | 100 mA DC |
Main circuit IN+
Connection Method | Push-in connection |
Stripping length | 15 mm |
Conductor cross section rigid | 0.2 mm² ... 10 mm² |
Conductor cross section AWG | 24 ... 8 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 4 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 6 mm² |
Main circuit IN-
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
Main circuit OUT
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
Remote indication circuit
Stripping length | 10 mm |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
Signaling
Channel LED off | off (Channel switched off) |
Channel LED yellow | lit (Channel switched on, channel load > 80% ) |
Channel LED yellow | flashing (Programming mode active) |
Channel LED green | lit (Channel switched on) |
Channel LED red | lit (Channel switched off, relay error, overvoltage or undervoltage active) |
Channel LED red | ON temporarily (Channel switched off, 5 s cool-down phase, overload or short-circuit release) |
Channel LED red | flashing (Channel switched off, ready to be switched back on, overload or short-circuit release) |
Channel LED red | two flashes (Channel switched off, device total current limit 32 A exceeded) |
Dimensions
Width | 36 mm |
Height | 90 mm |
Depth | 98 mm (incl. DIN rail 7.5 mm) |
Material specifications
Color | light grey (RAL 7035) |
Material | PC |
Material | PA 6.6 |
Material | PA 6.3T |
Material | POM |
Flammability rating according to UL 94 | V-0 |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 60 °C |
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Altitude | ≤ 3000 m up to 52 °C (amsl) |
Altitude | ≤ 4000 m up to 46 °C (amsl) |
Humidity test | 96 h, 95 % RH, 40 °C |
Corrosive gas test
Identification | ISA S71.04.2013 G3 Harsh Group A |
Standards and Regulations
Standards/specifications | EN 61000-6-2 |
Note | EMC – Immunity for industrial areas |
Standards/specifications | EN 61000-6-3 |
Note | EMC – Emission for residential, business and commercial properties and small operations |
Standards/specifications | EN 60068-2-78 |
Note | Environmental influences – Vibrations (sinusoidal) |
Standards/specifications | EN 50178 |
Note | Equipping power installations with electronic equipment |
Mounting
Mounting Type | DIN rail: 35 mm |
Why Proax for Phoenix Contact 1065730?
Proax is an authorized distributor of Phoenix Contact 1065730 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended