IB IL CNT - Inline function terminal

Inline counter terminal, without accessories, 1 counter input, 1 control input, 1 output, 24 V DC, 500 mA, 3-conductor connection technology

Technical Specifications

Product properties

Typemodular
TypeInline
Operating modeProcess data operation with 2 words
Diagnostics messagesSensor supply short-circuit
Diagnostics messagesSensor supply overload

Module

ID code (dec.)191
ID code (hex)BF
Length code (hex)02
Length code (dec)02
Process data channel32 bit
Input address area4 Byte
Output address area4 Byte
Register length4 Byte
Required parameter data 1 Byte
Required configuration data 5 Byte

Potentials: Communications power (UL)

Supply Voltage7.5 V DC (via voltage jumper)
Current drawmax. 50 mA
Current drawtyp. 40 mA
Power consumptionmax. 0.375 W (at UL)

Potentials: Segment circuit supply (US)

Supply Voltage24 V DC (via voltage jumper)
Current drawmax. 1 A

Supply:

DesignationPower supply for sensors
Supply Voltage24 V DC (generated from segment supply US)

Electrical isolation/isolation of the voltage ranges

Test voltage: 5 V supply, incoming remote bus/7.5 V supply (bus logics)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, outgoing remote bus/7.5 V supply (bus logics)500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.

Counter:

Input nameCounter input for 24 V signals
Connection MethodSpring-cage connection
Connection technology2-, 3-conductor
Number of Inputs1 (only one counter input can be used, either for 24 V or for 5 V signals)
Operating modeEvent counting, frequency/time measurement
Input Voltage24 V DC (Nominal voltage)
Input Voltage30 V DC (maximum)
Input voltage range "0" signal0 V DC ... 5 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Input Frequencymax. 100 kHz
Input Currenttyp. 5 mA
Input resistanceapprox. 5.7 kΩ
Input nameCounter input for 5 V signals
Connection MethodSpring-cage connection
Connection technology2-conductor (shielded), external 5 V supply
Number of Inputs1 (only one counter input can be used, either for 24 V or for 5 V signals)
Operating modeEvent counting, frequency/time measurement
Input Voltage5 V DC (Nominal voltage)
Input Voltage8 V DC (maximum)
Input voltage range "0" signal0 V ... 1.5 V
Input voltage range "1" signal3.5 V ... 8 V
Input Frequencymax. 100 kHz
Input Currenttyp. 5 mA
Input resistanceapprox. 1.7 kΩ

Digital:

Output nameSwitching output
Connection MethodSpring-cage connection
Connection technology2-conductor
Number of Outputs1
Protective circuitShort-circuit protection; Yes, short-circuit-proof (automatically switched on again)
Protective circuitOverload protection
Output Voltage24 V DC (Nominal voltage)
Output Currentmax. 0.5 A (Nominal current)
Nominal load, inductivemax. 12 VA (1.2 H, 48 Ω)
Nominal load, lampmax. 12 W
Nominal load, ohmicmax. 12 W (48 Ω)
Reverse voltage resistance to short pulsesReverse voltage proof
Behavior in the event of ohmic overloadAuto restart after eliminating the overload
Behavior with inductive overloadOutput can be destroyed
Behavior in the event of lamp overloadAuto restart after eliminating the overload
Overcurrent shut-downmin. 0.7 A

Inline connector

Connection MethodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Inline local bus

Connection MethodInline data jumper
Transmission Speed500 kbps
Transmission physicsCopper

Diagnostic messages

DiagnosticsSensor supply short-circuit
DiagnosticsSensor supply overload

Dimensions

Width24.4 mm
Height119.8 mm
Depth71.5 mm

Material specifications

Colorgreen

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 55 °C
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting

Why Proax for Phoenix Contact IB IL CNT?

Proax is an authorized distributor of Phoenix Contact IB IL CNT and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesIBILCNT
Pack Size1
Recommended

Available for order