Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2805318
Weight
0.034 kg
This product is Not Cancellable/Not Returnable
Series VAL-MS

VAL-MS 75 VF ST - Type 2 surge protection plug

Surge protection plug type 2 with series connection consisting of varistor and gas-filled spark gap for VAL-MS base element, thermal monitoring, visual fault warning.

Technical Specifications

General

NoteThe values specified for the L-L protective path are only valid in connection with VAL-MS/2+0-BE/FM/S2

Product properties

Product familyVALVETRAB MS
IEC test classificationII
IEC test classificationT2
EN typeT2
TypeDIN rail module, two-section, divisible
Number of Positions1
Surge protection fault messageoptical

Insulation characteristics

Overvoltage categoryIII
Pollution degree2

Electrical properties

Nominal frequency fN50 Hz (60 Hz)
Nominal voltage UN5 V AC ... 48 V AC

Connection data

Connection Methodpluggable

Dimensions

Width17.5 mm
Height52.4 mm
Depth55.3 mm
Horizontal pitch1 Div.

Material specifications

Colorblack (RAL 9005)
Flammability rating according to UL 94V-0
CTI value of material600
Insulating materialPA 6.6
Material groupI
Housing MaterialPA 6.6

Protective circuit

Mode of protectionL-PE
Mode of protectionL-L
Direction of action1L-N/PE
Nominal voltage UN5 V AC ... 48 V AC
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC75 V AC
Maximum continuous voltage UC100 V DC
Residual current IPE≤ 5 µA
Standby power consumption PC≤ 1.00 mVA
Nominal discharge current In (8/20) µs10 kA
Maximum discharge current Imax (8/20) µs20 kA
Short-circuit current rating ISCCR10 kA
Voltage protection level Up≤ 1.4 kV
Voltage protection level Up (L-L)≤ 1.8 kV
Residual voltage Ures≤ 0.45 kV (at In)
Residual voltage Ures≤ 0.35 kV (at 5 kA)
Residual voltage Ures≤ 0.3 kV (at 3 kA)
Residual voltage Ures (L-L)≤ 0.9 kV (at In)
Residual voltage Ures (L-L)≤ 0.7 kV (at 5 kA)
Residual voltage Ures (L-L)≤ 0.6 kV (at 3 kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs≤ 1.4 kV
Response time tA≤ 100 ns
Max. backup fuse with branch wiring63 A (gG)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl)
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g
Vibration (Operation)5g

UL specifications

Maximum continuous operating voltage MCOV (L-N)75 V AC
Maximum continuous operating voltage MCOV (L+) - (L-)100 V DC
Nominal discharge current In (L-N)10 kA
Nominal discharge current In (L+) - (L-)10 kA
Mode of protectionL-N
Mode of protection(L+) - (L-)
Nominal Voltage48 V AC
Nominal Voltage60 V DC
Power distribution systemSingle phase
Nominal frequency50/60 Hz
Measured limiting voltage MLV (L-N)1760 V
Measured limiting voltage MLV (L+) - (L-)1760 V
SPD Type4CA

Standards and Regulations

Standards/specificationsIEC 61643-11
Note2011
Standards/specificationsEN 61643-11
Note2012

Mounting

Mounting Typeon base element
Accessories

Why Proax for Phoenix Contact VAL-MS 75 VF ST?

Proax is an authorized distributor of Phoenix Contact VAL-MS 75 VF ST and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesVALMS75VFST
Pack Size1
Recommended

Available for order