SAC-4P-M 8FR/.../... - Sensor/actuator cable

Sensor/actuator cable, 4-position, free cable end, on Socket angled M8, coding: A, cable length: Free input (0.2 ... 40.0 m)

  • Easy and safe: 100 % electrically tested plug-in components

SAC-4P

The Phoenix Contact SAC-4P Series comprises 4-position sensor/actuator cables designed for reliable signal transmission in industrial automation applications. These cables are engineered to provide secure and efficient connections between sensors, actuators, and control systems. Key Features: Connector Types: The SAC-4P Series offers cables with M12 connectors in both straight and angled configurations, providing flexibility for various installation scenarios. Cable Materials: Cables are available with halogen-free polyurethane (PUR) or polyvinyl chloride (PVC) jackets, ensuring durability and resistance to environmental factors. Shielding Options: Some models feature advanced shielding technology to protect against electromagnetic interference, ensuring signal integrity in environments with high electrical noise. Coding: Equipped with A-coding, these cables are standardized for sensor/actuator connections, ensuring compatibility across various devices.
Technical Specifications

Product properties

ApplicationStandard
ApplicationRobots and drag chains
Number of Positions4
No. of cable outlets1
Shieldedno
CodingA

Insulation characteristics

Overvoltage categoryII
Degree of pollution3

Material specifications

Flammability rating according to UL 94HB
Seal materialNBR
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact MaterialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties

Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
Nominal voltage UN60 V DC
Nominal current IN4 A

Mechanical data

Insertion/withdrawal cycles≥ 100

Signaling

Status displayNo
Status display presentNo

Conductor connection

Tightening torque0.2 Nm (M8 connectors)

Connection 1

Typefree cable end

Connection 2

TypeSocket angled M8
Number of Positions4
Coding typeA

Cable/line

Cable LengthFree input (0.2 ... 40.0 m)

PUR halogen-free black [PUR]

Cable weight23 kg/km
UL AWM style20549 / 10493 (80°C/300 V)
Number of Positions4
Shieldedno
Cable TypePUR halogen-free black [PUR]
Cable TypePUR halogen-free black PUR
Conductor structure signal line32x 0.10 mm
AWG Signal Line24
Conductor Cross Section4x 0.25 mm² (Signal line)
Wire diameter incl. insulation1.17 mm ±0.02 mm (Signal line)
External Cable Diameter3.95 mm ±0.15 mm
Outer sheath, materialPUR
External sheath, colorblack-gray RAL 7021
Conductor materialBare Cu litz wires
Material wire insulationPP
Single wire, colorbrown, white, blue, black
Thickness, insulation≥ 0.21 mm (Core insulation)
Thickness, insulationapprox. 0.50 mm (Outer cable sheath)
Overall twist4 wires, twisted
Max. conductor resistancemax. 78 Ω/km (at 20 °C)
Insulation resistance≥ 100 GΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Smallest bending radius, fixed installation20 mm
Smallest bending radius, movable installation40 mm
Max. bending cycles10000000
Halogen-freein accordance with DIN VDE 0472 part 815
Flame resistancein accordance with UL 758/1581 FT2
Flame resistanceDIN EN 60332-2-2 (20 s)
Resistance to Oilin accordance with DIN EN 60811-2-1
Other resistanceHighly resistant to acids, alkaline solutions and solvents
Other resistancehydrolysis and microbe resistant
Other resistancepartly UV-resistant (in accordance with DIN EN ISO 4892-2-A)
Special PropertiesFlexible cable conduit capable
Special PropertiesSilicone-free
Special PropertiesFree of substances which would hinder coating with paint or varnish
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable, flexible installation)

PUR halogen-free gray [280]

Cable weight23 kg/km
UL AWM style20549 / 10493 (80°C/300 V)
Number of Positions4
Shieldedno
Cable TypePUR halogen-free gray [280]
Cable TypePUR halogen-free gray 280
Conductor structure signal line32x 0.10 mm
AWG Signal Line24
Conductor Cross Section4x 0.25 mm² (Signal line)
Wire diameter incl. insulation1.17 mm ±0.02 mm (Signal line)
External Cable Diameter3.95 mm ±0.15 mm
Outer sheath, materialPUR
External sheath, colorgray RAL 7001
Conductor materialBare Cu litz wires
Material wire insulationPP
Single wire, colorbrown, white, blue, black
Thickness, insulation≥ 0.21 mm (Core insulation)
Thickness, insulationapprox. 0.50 mm (Outer cable sheath)
Overall twist4 wires, twisted
Max. conductor resistancemax. 78 Ω/km (at 20 °C)
Insulation resistance≥ 100 GΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Smallest bending radius, fixed installation20 mm
Smallest bending radius, movable installation40 mm
Max. bending cycles10000000
Halogen-freein accordance with DIN VDE 0472 part 815
Flame resistancein accordance with UL 758/1581 FT2
Flame resistanceDIN EN 60332-2-2 (20 s)
Resistance to Oilin accordance with DIN EN 60811-2-1
Other resistanceHighly resistant to acids, alkaline solutions and solvents
Other resistancehydrolysis and microbe resistant
Other resistancepartly UV-resistant (in accordance with DIN EN ISO 4892-2-A)
Special PropertiesFlexible cable conduit capable
Special PropertiesSilicone-free
Special PropertiesFree of substances which would hinder coating with paint or varnish
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable, flexible installation)

PUR halogen-free yellow [240]

Cable weight25 kg/km
UL AWM style20549
Number of Positions4
Shieldedno
Cable TypePUR halogen-free yellow [240]
Cable TypePUR halogen-free yellow 240
Conductor structure signal line32x 0.10 mm
AWG Signal Line24
Conductor Cross Section4x 0.25 mm² (Signal line)
Wire diameter incl. insulation1.17 mm ±0.02 mm
External Cable Diameter4.40 mm ±0.15 mm
Outer sheath, materialPUR
External sheath, coloryellow, similar to RAL 1021
Conductor materialBare Cu litz wires
Material wire insulationPP
Single wire, colorbrown, white, blue, black
Thickness, insulation≥ 0.21 mm
Thickness, outer sheathapprox. 0.75 mm
Overall twist4 wires, twisted
Length of twist, overall twist45 mm
Max. conductor resistance78 Ω/km (at 20 °C)
Insulation resistance≥ 1 GΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V AC
Test voltage≥ 3000 V AC (Spark test)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation22 mm
Smallest bending radius, movable installation44 mm
Max. bending cycles4000000
Halogen-freein accordance with DIN VDE 0472 part 815
Halogen-freein accordance with EN 50267-2-1
Flame resistancein accordance with UL 758/1581 FT2
Resistance to OilAccording to DIN EN 60811-2-1, 168 h at 100°C
Resistance to OilAccording to UL 758, 168 h at 60°C
Other resistancehydrolysis and microbe resistant
Other resistanceResistant to salt water
Other resistanceabrasion-resistant
Other resistanceLow adhesion
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable, flexible installation)

PUR halogen-free orange [180]

Cable weight25 kg/km
UL AWM style20549
Number of Positions4
Shieldedno
Cable TypePUR halogen-free orange [180]
Cable TypePUR halogen-free orange 180
Conductor structure signal line32x 0.10 mm
AWG Signal Line24
Conductor Cross Section4x 0.25 mm² (Signal line)
Wire diameter incl. insulation1.17 mm ±0.02 mm (Signal line)
External Cable Diameter4.40 mm ±0.15 mm
Outer sheath, materialPUR
External sheath, colororange RAL 2003
Conductor materialBare Cu litz wires
Material wire insulationPP
Single wire, colorbrown, white, blue, black
Thickness, insulation≥ 0.21 mm (Core insulation)
Thickness, insulation0.75 mm (Outer cable sheath)
Overall twist4 wires, twisted
Max. conductor resistancemax. 78 Ω/km (at 20 °C)
Insulation resistance≥ 10 GΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Smallest bending radius, fixed installation22 mm
Halogen-freein accordance with DIN VDE 0472 part 815
Flame resistancein accordance with DIN UL-Style 20549
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable)

PVC black [PVC]

Cable weight33 kg/km
UL AWM style2464 / 1729 (80°C/300 V)
Number of Positions4
Shieldedno
Cable TypePVC black [PVC]
Cable TypePVC black PVC
Conductor structure signal line14x 0.15 mm
AWG Signal Line24
Conductor Cross Section4x 0.25 mm² (Signal line)
Wire diameter incl. insulation1.17 mm ±0.05 mm
External Cable Diameter4.40 mm ±0.15 mm
Outer sheath, materialPVC
External sheath, colorblack RAL 9005
Conductor materialBare Cu litz wires
Material wire insulationPVC
Single wire, colorbrown, white, blue, black
Thickness, insulation≥ 0.23 mm (Core insulation)
Thickness, insulation≥ 0.76 mm (Outer cable sheath)
Overall twist4 wires, twisted
Max. conductor resistancemax. 79 Ω/km (at 20 °C)
Insulation resistance≥ 100 MΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Minimum bending radius, fixed installation5 x D
Smallest bending radius, fixed installation22 mm
Flame resistanceAs per UL-Style 2464
Resistance to OilEN 60811-2-1
Ambient Temperature (Operation)-25 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-10 °C ... 80 °C (Cable, flexible installation)

PVC gray [500]

Cable weight33 kg/km
Number of Positions4
Shieldedno
Cable TypePVC gray [500]
Cable TypePVC gray 500
Conductor structure signal line14x 0.15 mm
AWG Signal Line24
Conductor Cross Section4x 0.25 mm² (Signal line)
Wire diameter incl. insulation1.17 mm ±0.05 mm
External Cable Diameter4.40 mm ±0.15 mm
Outer sheath, materialPVC
External sheath, colorgray RAL 7001
Conductor materialBare Cu litz wires
Material wire insulationPVC
Single wire, colorbrown, white, blue, black, green-yellow
Thickness, insulation≥ 0.23 mm (Core insulation)
Thickness, insulation≥ 0.76 mm (Outer cable sheath)
Overall twist4 wires, twisted
Max. conductor resistancemax. 79 Ω/km (at 20 °C)
Insulation resistance≥ 100 MΩ*km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage≥ 3000 V
Flame resistanceAs per UL-Style 2464
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable, flexible installation)

Gray, highly flexible PUR [800]

NoteDue to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments.
Cable weight27.1 kg/km
UL AWM style20549
Number of Positions4
Shieldedno
Cable TypeGray, highly flexible PUR [800]
Cable TypeGray, highly flexible PUR 800
Conductor structure signal line32x 0.10 mm
AWG Signal Line24
Conductor Cross Section4x 0.25 mm² (Signal line)
Wire diameter incl. insulation1.15 mm ±0.05 mm (Signal line)
External Cable Diameter4.50 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorgray RAL 7001
Conductor materialBare Cu litz wires
Material wire insulationPP
Single wire, colorbrown, white, blue, black
Overall twist4 wires, twisted
Max. conductor resistanceapprox. 76 Ω/km
Insulation resistance≥ 20 MΩ*km
Nominal voltage, cable300 V
Test voltage1200 V
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation7.5 x D
Smallest bending radius, fixed installation18 mm
Smallest bending radius, movable installation34 mm
Max. bending cycles10000000
Max. bending cycles15000000
Torsion force± 360 °/m
Torsion cycles1000000
Torsional frequency1000000
Halogen-freein accordance with DIN VDE 0472 part 815
Flame resistancein accordance with UL 758/1581 FT2
Resistance to Oilin accordance with DIN EN 60811-2-1
Other resistanceHighly resistant to acids, alkaline solutions and solvents
Other resistanceSilicone-free
Special PropertiesCable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing
Special PropertiesFree from silicone and cadmium
Special PropertiesFree of substances which would hinder coating with paint or varnish
Ambient Temperature (Operation)-40 °C ... 80 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 80 °C (Cable, flexible installation)

Ambient conditions

Degree of ProtectionIP65
Degree of ProtectionIP67
Degree of ProtectionIP68
Ambient Temperature (Operation)-25 °C ... 90 °C (Plug / socket)

Standards and Regulations

Standard designationM8 connector
Standards/specificationsIEC 61076-2-104
Accessories

Why Proax for Phoenix Contact 1697784?

Proax is an authorized distributor of Phoenix Contact 1697784 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability