AFS750-30-12-71

ABBOfficial Distributor

By ABB

SKU
ABBAFS750301271
MPN
1SFL637081R7112
Weight
10 kg
The AFS750-30-12-71 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted 1 left (1 N.O + 1 N.C.) and fixed 1 right (1 N.C.) side mounted auxiliary contact blocks with Main Circuit Bars connections, controlling motors up to 400 kW / 400 V AC (AC-3) or 600 hp / 480 V UL and switching power circuits up to 1050 A (AC-1) or 900 A UL general use. AFS contactors can be easily integrated in machine manufacturer’s systems complying with main standards EN ISO 13849 and EN 62061 - guaranteeing the safe use of your machinery and equipment. An easily identifiable yellow low energy auxiliary contact block ensures the status feedback circuits required in machine safety applications. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

AFS contactors for safety applications

AFS contactors are specifically designed to enhance safety in machine applications. Featuring factory-mounted contact blocks with mechanically linked and mirror contacts, these contactors ensure reliable monitoring and control of circuits. With ABB’s comprehensive safety component range, building protection systems becomes more straightforward and efficient.

Main Benefits:

  • Safety Compliance: Meets major safety standards (EN ISO 13849 and EN 62061) for secure machinery and equipment use.

  • Guaranteed Status: Factory-mounted auxiliary contact blocks ensure accurate contactor status monitoring.

  • Easy Identification: Distinct yellow housing simplifies safety chain recognition.

  • Streamlined Safety Calculations: Safety values available in FSDT and Sistema tools for easier safety level assessments.

Main Features:

  • High Power Handling:

    • Up to 400 kW at 400 V AC-3

    • Up to 600 hp at 480 V

    • Up to 1050 A at 690 V AC-1

    • Up to 900 A for general use

  • Certified Safety Contacts: Mirror and mechanically linked contacts with third-party certification.

  • Fast Response: Opening times as low as 20 ms in certain models with PLC interfaces.

  • Precision Switching: Low-energy auxiliary contacts with a minimum switching capacity of 12 V, 3 mA (10⁻⁷).

  • Built-in Protection: Integrated surge suppression for enhanced safety.

Technical Specifications

Dimensions

Product Net Width210 mm
Product Net Depth / Length242 mm
Product Net Height283 mm
Product Net Weight10 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC2
Number of Poles3P
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 1000 A
Rated Operational Current AC-1 (Ie)(1000 V) 55 °C 875 A
Rated Operational Current AC-1 (Ie)(1000 V) 70 °C 720 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 1050 A
Rated Operational Current AC-1 (Ie)(690 V) 55 °C 875 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 720 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 750 A
Rated Operational Current AC-3 (Ie)(440 V) 55 °C 750 A
Rated Operational Current AC-3 (Ie)(500 V) 55 °C 750 A
Rated Operational Current AC-3 (Ie)(690 V) 55 °C 650 A
Rated Operational Current AC-3 (Ie)(1000 V) 55 °C 300 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 55 °C 750 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 55 °C 750 A
Rated Operational Current DC-1 (Ie)(110 V) 1-Pole, 40 °C 1050 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-1 (Ie)(600 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-1 (Ie)(850 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-3 (Ie)(110 V) 1-Pole, 40 °C 1050 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-3 (Ie)(600 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-3 (Ie)(850 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-5 (Ie)(110 V) 1-Pole, 40 °C 1050 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-5 (Ie)(600 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-5 (Ie)(850 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Power AC-3 (Pe)(415 V) 425 kW
Rated Operational Power AC-3 (Pe)(440 V) 450 kW
Rated Operational Power AC-3 (Pe)(500 V) 520 kW
Rated Operational Power AC-3 (Pe)(690 V) 600 kW
Rated Operational Power AC-3 (Pe)(1000 V) 400 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 400 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 220 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 1000 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1300 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 4500 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 7000 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 6400 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3500 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Maximum Electrical Switching Frequency(AC-2 / AC-4) 60 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 300 cycles per hour
Mechanical Durability3 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 250 ... 500 V
Rated Control Circuit Voltage (Uc)60 Hz 250 ... 500 V
Rated Control Circuit Voltage (Uc)DC Operation 250 ... 500 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage DC 5.5 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 50 Hz 985 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 60 Hz 985 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage DC 910 V·A
Power Lossat Rated Operating Conditions per Pole 50 W
Operate TimeBetween Coil De-energization and NC Contact Closing 50 ... 70 ms
Operate TimeBetween Coil De-energization and NO Contact Opening 53 ... 73 ms
Operate TimeBetween Coil Energization and NC Contact Opening 45 ... 115 ms
Operate TimeBetween Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main CircuitBar 52 mm²
Connecting Capacity Main CircuitBar 50 mm²
Connecting Capacity Main CircuitRigid Al-Cable 300 mm²
Connecting Capacity Main CircuitRigid Al-Cable 3x185 mm²
Connecting Capacity Main CircuitRigid Cu-Cable 300 mm²
Connecting Capacity Main CircuitRigid Cu-Cable 3x185 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible 1x0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible 2x0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitSolid 2 x 1 ... 4 mm²
Connecting Capacity Auxiliary CircuitStranded 2 x 1 .... 4 mm²
Connecting CapacityBar 52 mm²
Connecting CapacityRigid Al-Cable 3x185 mm²
Connecting CapacityRigid Cu-Cable 3x185 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main PolesM 3.5 (+,-) pozidriv 2 screw with cable clamp
Recommended Screw DriverMain Circuit M12
Recommended Screw DriverControl Circuit 5.5
Recommended Screw DriverControl Circuit M3.5
Recommended Screw DriverControl Circuit Pozidriv 2
Tightening torqueCable Lug 45 N·m
Tightening torqueMain Circuit 45 N·m
Terminal TypeMain Circuit: Bars
Suitable for Product ClassBlock ContactorsBlock Contactors
Product NameBlock Contactor

Technical UL/CSA

NEMA Size7
Horsepower Rating NEMA(230 V AC) Three Phase 300 Hp
Horsepower Rating NEMA(460 V AC) Three Phase 600 Hp
Horsepower Rating NEMA(575 V AC) Three Phase 600 Hp
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(1000 V AC) 900 A
General Use Rating UL/CSA(600 V AC) 900 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 250 Hp
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 250 hp
Horsepower Rating UL/CSA(200 V AC) Three Phase 250 hp
Horsepower Rating UL/CSA(208 V AC) Three Phase 250 hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 300 Hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 300 hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 600 Hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 600 hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 700 Hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 700 hp
Full Load Amps Motor Use(200 ... 208 V AC) Three Phase 692.3 A
Full Load Amps Motor Use(220 ... 240 V AC) Three Phase 722 A
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 722 A
Full Load Amps Motor Use(550 ... 600 V AC) Three Phase 672 A

ABB EcoSolutions

End Of Life Disassembling Instructions1SFC100112M0004
Environmental Product Declaration - EPD1SFC100109D0201

Why Proax for ABB AFS750-30-12-71?

Proax is an authorized distributor of ABB AFS750-30-12-71 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesAFS750301271
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability