CADEN
Cart

AF205B-30-22RT-12

Official Distributor

By ABB

SKU
ABBAF205B3022RT12
MPN
1SFL527062R1222
Weight
2.4 kg
The AF205B-30-22RT-12 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and ring tongue ferrules, controlling motors up to 110 kW / 400 V AC (AC-3) or 150 hp / 480 V UL and switching power circuits up to 350 A (AC-1) or 300 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. Includes Mounting kit, containing all neccessary screws, washers and sockets for connecting the terminals, and screws for mounting the device.
Technical Specifications

Dimensions

Product Net Width105 mm
Product Net Depth / Length152 mm
Product Net Height196 mm
Product Net Weight2.4 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Number of Poles3P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 275 A
Rated Operational Current AC-1 (Ie)(1000 V) 60 °C 250 A
Rated Operational Current AC-1 (Ie)(1000 V) 70 °C 200 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 350 A
Rated Operational Current AC-1 (Ie)(690 V) 60 °C 300 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 240 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 205 A
Rated Operational Current AC-3 (Ie)(440 V) 55 °C 205 A
Rated Operational Current AC-3 (Ie)(500 V) 55 °C 165 A
Rated Operational Current AC-3 (Ie)(690 V) 55 °C 165 A
Rated Operational Current AC-3 (Ie)(1000 V) 55 °C 100 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 55 °C 205 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 55 °C 205 A
Rated Operational Current DC-1 (Ie)(100 V) 1 Pole, 40 °C 350 A
Rated Operational Current DC-1 (Ie)(100 V) 1 Pole, 60 °C 300 A
Rated Operational Current DC-1 (Ie)(100 V) 1 Pole, 70 °C 240 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 350 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 60 °C 300 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 70 °C 240 A
Rated Operational Current DC-1 (Ie)(110 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-1 (Ie)(110 V) 3 Poles in Series, 60 °C 300 A
Rated Operational Current DC-1 (Ie)(110 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Current DC-1 (Ie)(175 V) 2 Poles in Series, 40 °C 350 A
Rated Operational Current DC-1 (Ie)(175 V) 2 Poles in Series, 60 °C 300 A
Rated Operational Current DC-1 (Ie)(175 V) 2 Poles in Series, 70 °C 240 A
Rated Operational Current DC-1 (Ie)(200 V) 2 Poles in Series, 40 °C 350 A
Rated Operational Current DC-1 (Ie)(200 V) 2 Poles in Series, 60 °C 300 A
Rated Operational Current DC-1 (Ie)(200 V) 2 Poles in Series, 70 °C 240 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 60 °C 300 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Current DC-1 (Ie)(260 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-1 (Ie)(260 V) 3 Poles in Series, 60 °C 300 A
Rated Operational Current DC-1 (Ie)(260 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Current DC-1 (Ie)(300 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-1 (Ie)(300 V) 3 Poles in Series, 60 °C 300 A
Rated Operational Current DC-1 (Ie)(300 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Current DC-1 (Ie)(72 V) 1-Pole, 40 °C 350 A
Rated Operational Current DC-1 (Ie)(72 V) 1-Pole, 60 °C 300 A
Rated Operational Current DC-1 (Ie)(72 V) 1-Pole, 70 °C 240 A
Rated Operational Current DC-1 (Ie)(72 V) 2 Poles in Series, 40 °C 350 A
Rated Operational Current DC-1 (Ie)(72 V) 2 Poles in Series, 60 °C 300 A
Rated Operational Current DC-1 (Ie)(72 V) 2 Poles in Series, 70 °C 240 A
Rated Operational Current DC-1 (Ie)(72 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-1 (Ie)(72 V) 3 Poles in Series, 60 °C 300 A
Rated Operational Current DC-1 (Ie)(72 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Current DC-1 (Ie)(90 V) 1 Pole, 40 °C 350 A
Rated Operational Current DC-1 (Ie)(90 V) 1 Pole, 60 °C 300 A
Rated Operational Current DC-1 (Ie)(90 V) 1 Pole, 70 °C 240 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 275 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 60 °C 275 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 70 °C 240 A
Rated Operational Current DC-3 (Ie)(110 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Current DC-3 (Ie)(110 V) 3 Poles in Series, 60 °C 275 A
Rated Operational Current DC-3 (Ie)(110 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 60 °C 275 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Current DC-3 (Ie)(72 V) 2 Poles in Series, 40 °C 275 A
Rated Operational Current DC-3 (Ie)(72 V) 2 Poles in Series, 60 °C 275 A
Rated Operational Current DC-3 (Ie)(72 V) 2 Poles in Series, 70 °C 240 A
Rated Operational Current DC-3 (Ie)(72 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Current DC-3 (Ie)(72 V) 3 Poles in Series, 60 °C 275 A
Rated Operational Current DC-3 (Ie)(72 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 275 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 60 °C 275 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 70 °C 240 A
Rated Operational Current DC-5 (Ie)(110 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Current DC-5 (Ie)(110 V) 3 Poles in Series, 60 °C 275 A
Rated Operational Current DC-5 (Ie)(110 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 60 °C 275 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Current DC-5 (Ie)(72 V) 2 Poles in Series, 40 °C 275 A
Rated Operational Current DC-5 (Ie)(72 V) 2 Poles in Series, 60 °C 275 A
Rated Operational Current DC-5 (Ie)(72 V) 2 Poles in Series, 70 °C 240 A
Rated Operational Current DC-5 (Ie)(72 V) 3 Poles in Series, 40 °C 275 A
Rated Operational Current DC-5 (Ie)(72 V) 3 Poles in Series, 60 °C 275 A
Rated Operational Current DC-5 (Ie)(72 V) 3 Poles in Series, 70 °C 240 A
Rated Operational Power AC-3 (Pe)(415 V) 110 kW
Rated Operational Power AC-3 (Pe)(440 V) 132 kW
Rated Operational Power AC-3 (Pe)(500 V) 110 kW
Rated Operational Power AC-3 (Pe)(690 V) 160 kW
Rated Operational Power AC-3 (Pe)(1000 V) 132 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 110 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3e8.5 x Ie AC-3e
Rated Making Capacity AC-310 x Ie AC-3
Rated Making Capacity AC-3e12 x Ie AC-3e
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 947 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2050 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1640 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 670 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 300 cycles per hour
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz / 60 Hz 48 ... 130 V
Rated Control Circuit Voltage (Uc)DC Operation 48 ... 130 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 4 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 60 Hz 4 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 60 Hz 180 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage DC 150 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage DC 150 W
Power Loss8 W
Power Lossat Rated Operating Conditions per Pole 8 W
Connecting Capacity Main CircuitFlexible 2 x 50 ... 95 mm²
Connecting Capacity Main CircuitRigid Cu-Cable 2 x 50 ... 120 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible 2x0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitSolid 2 x 1 ... 4 mm²
Connecting Capacity Auxiliary CircuitStranded 2 x 1 .... 4 mm²
Connecting CapacityFlexible 2 x 50 ... 95 mm²
Connecting CapacityRigid Cu-Cable 2 x 50 ... 120 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening torqueCable Lug 9 N·m
Tightening torqueMain Circuit 14 ... 31 N·m
Terminal TypeMain Circuit: Bars
Product NameBlock Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(1000 V AC) 275 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 60 hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 75 hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 150 hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 200 hp
Full Load Amps Motor Use(200 ... 208 V AC) Three Phase 177 A
Full Load Amps Motor Use(220 ... 240 V AC) Three Phase 192 A
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 180 A
Full Load Amps Motor Use(550 ... 600 V AC) Three Phase 192 A

ABB EcoSolutions

End Of Life Disassembling Instructions1SFC100112M0001

Why Proax for ABB AF205B-30-22RT-12?

Proax is an authorized distributor of ABB AF205B-30-22RT-12 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesAF205B3022RT12
Pack Size1
Recommended

CAD$2,875.25

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability