
AF205B-30-22-14
By ABB
SKU
ABBAF205B302214
MPN
1SFL527063R1422
Weight
1 kg
The AF205B-30-22-14 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and standard ferrules, controlling motors up to 110 kW / 400 V AC (AC-3) or 150 hp / 480 V UL and switching power circuits up to 350 A (AC-1) or 300 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz ), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Technical Specifications
Dimensions
| Product Net Width | 105 mm |
| Product Net Depth / Length | 152 mm |
| Product Net Height | 196 mm |
| Product Net Weight | 2.4 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 2 |
| Number of Auxiliary Contacts NC | 2 |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives. |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 275 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 60 °C 250 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 70 °C 200 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 350 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 60 °C 300 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 70 °C 240 A |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 205 A |
| Rated Operational Current AC-3 (Ie) | (440 V) 55 °C 205 A |
| Rated Operational Current AC-3 (Ie) | (500 V) 55 °C 165 A |
| Rated Operational Current AC-3 (Ie) | (690 V) 55 °C 165 A |
| Rated Operational Current AC-3 (Ie) | (1000 V) 55 °C 100 A |
| Rated Operational Current AC-3 (Ie) | (380 / 400 V) 55 °C 205 A |
| Rated Operational Current AC-3 (Ie) | (220 / 230 / 240 V) 55 °C 205 A |
| Rated Operational Power AC-3 (Pe) | (415 V) 110 kW |
| Rated Operational Power AC-3 (Pe) | (440 V) 132 kW |
| Rated Operational Power AC-3 (Pe) | (500 V) 110 kW |
| Rated Operational Power AC-3 (Pe) | (690 V) 160 kW |
| Rated Operational Power AC-3 (Pe) | (1000 V) 132 kW |
| Rated Operational Power AC-3 (Pe) | (380 / 400 V) 110 kW |
| Rated Operational Power AC-3 (Pe) | (220 / 230 / 240 V) 55 kW |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A |
| Rated Operational Current DC-1 (Ie) | (100 V) 1 Pole, 40 °C 350 A |
| Rated Operational Current DC-1 (Ie) | (100 V) 1 Pole, 60 °C 300 A |
| Rated Operational Current DC-1 (Ie) | (100 V) 1 Pole, 70 °C 240 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 350 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 60 °C 300 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 3 Poles in Series, 40 °C 350 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 3 Poles in Series, 60 °C 300 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 3 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-1 (Ie) | (175 V) 2 Poles in Series, 40 °C 350 A |
| Rated Operational Current DC-1 (Ie) | (175 V) 2 Poles in Series, 60 °C 300 A |
| Rated Operational Current DC-1 (Ie) | (175 V) 2 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-1 (Ie) | (200 V) 2 Poles in Series, 40 °C 350 A |
| Rated Operational Current DC-1 (Ie) | (200 V) 2 Poles in Series, 60 °C 300 A |
| Rated Operational Current DC-1 (Ie) | (200 V) 2 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 40 °C 350 A |
| Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 60 °C 300 A |
| Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-1 (Ie) | (260 V) 3 Poles in Series, 40 °C 350 A |
| Rated Operational Current DC-1 (Ie) | (260 V) 3 Poles in Series, 60 °C 300 A |
| Rated Operational Current DC-1 (Ie) | (260 V) 3 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-1 (Ie) | (300 V) 3 Poles in Series, 40 °C 350 A |
| Rated Operational Current DC-1 (Ie) | (300 V) 3 Poles in Series, 60 °C 300 A |
| Rated Operational Current DC-1 (Ie) | (300 V) 3 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 1-Pole, 40 °C 350 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 1-Pole, 60 °C 300 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 1-Pole, 70 °C 240 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 2 Poles in Series, 40 °C 350 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 2 Poles in Series, 60 °C 300 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 2 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 3 Poles in Series, 40 °C 350 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 3 Poles in Series, 60 °C 300 A |
| Rated Operational Current DC-1 (Ie) | (72 V) 3 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-1 (Ie) | (90 V) 1 Pole, 40 °C 350 A |
| Rated Operational Current DC-1 (Ie) | (90 V) 1 Pole, 60 °C 300 A |
| Rated Operational Current DC-1 (Ie) | (90 V) 1 Pole, 70 °C 240 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 275 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 60 °C 275 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 3 Poles in Series, 40 °C 275 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 3 Poles in Series, 60 °C 275 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 3 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 40 °C 275 A |
| Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 60 °C 275 A |
| Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-3 (Ie) | (72 V) 2 Poles in Series, 40 °C 275 A |
| Rated Operational Current DC-3 (Ie) | (72 V) 2 Poles in Series, 60 °C 275 A |
| Rated Operational Current DC-3 (Ie) | (72 V) 2 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-3 (Ie) | (72 V) 3 Poles in Series, 40 °C 275 A |
| Rated Operational Current DC-3 (Ie) | (72 V) 3 Poles in Series, 60 °C 275 A |
| Rated Operational Current DC-3 (Ie) | (72 V) 3 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 275 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 60 °C 275 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 3 Poles in Series, 40 °C 275 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 3 Poles in Series, 60 °C 275 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 3 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 40 °C 275 A |
| Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 60 °C 275 A |
| Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-5 (Ie) | (72 V) 2 Poles in Series, 40 °C 275 A |
| Rated Operational Current DC-5 (Ie) | (72 V) 2 Poles in Series, 60 °C 275 A |
| Rated Operational Current DC-5 (Ie) | (72 V) 2 Poles in Series, 70 °C 240 A |
| Rated Operational Current DC-5 (Ie) | (72 V) 3 Poles in Series, 40 °C 275 A |
| Rated Operational Current DC-5 (Ie) | (72 V) 3 Poles in Series, 60 °C 275 A |
| Rated Operational Current DC-5 (Ie) | (72 V) 3 Poles in Series, 70 °C 240 A |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Rated Control Circuit Voltage (Uc) | 50 Hz / 60 Hz 250 ... 500 V |
| Rated Control Circuit Voltage (Uc) | DC Operation 250 ... 500 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 260 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 260 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage DC 230 W |
| Terminal Type | Main Circuit: Bars |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 300 A |
| Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 60 hp |
| Horsepower Rating UL/CSA | (220 ... 240 V AC) Three Phase 75 hp |
| Horsepower Rating UL/CSA | (440 ... 480 V AC) Three Phase 150 hp |
| Horsepower Rating UL/CSA | (550 ... 600 V AC) Three Phase 200 hp |
Why Proax for ABB AF205B-30-22-14?
Proax is an authorized distributor of ABB AF205B-30-22-14 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Alternate Names | AF205B302214 |
| Pack Size | 1 |
Recommended



















