Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
SAC-4P-M12MSD/25,5-936/DS ST3
Weight
2.043 kg
Series SAC-4P

SAC-4P-M12MSD/25,5-936/DS ST3 - Sensor/actuator cable

Sensor/actuator cable, 4-position, PE-X halogen-free, black RAL 9005, shielded (Plastic-coated aluminum foil, tinned copper braided shield), Plug straight M12, coding: D, on Plug straight D-SUB 9, cable length: 25.5 m

Technical Specifications

Product properties

Number of Positions4
Shieldedyes
CodingD

Electrical properties

Nominal voltage UN48 V AC
Nominal voltage UN60 V DC

Mechanical data

Insertion/withdrawal cycles≥ 100

Connection 1

TypePlug straight M12
Coding typeD (Data)

Connection 2

TypePlug straight D-SUB 9

Cable/line

Cable Length25.5 m

PROFINET RADOX® railway application CAT5 reinforced [936]

Cable weight81 g/m
Number of Positions4
Shieldedyes
Cable TypePROFINET RADOX® railway application CAT5 reinforced [936]
Conductor structure1x4xAWG22/7, SF/TQ
Signal speed66 c
Conductor structure signal line7x 0.25 mm
AWG Signal Line22
Conductor Cross Section4x 0.34 mm²
Wire diameter incl. insulation1.95 mm
External Cable Diameter7.25 mm ±0.3 mm
Outer sheath, materialPE-X
External sheath, colorblack RAL 9005
Conductor materialsilver-plated Cu litz wires
Material wire insulationPE-X
Single wire, colorwhite-blue, orange-yellow
Thickness, outer sheath≥ 0.80 mm
Overall twistStar quad
Optical shield covering100 %
Max. conductor resistance≤ 54.4 Ω/km
Coupling resistance200.00 mΩ/m (f ≤ 30 MHz)
Wave impedance100 Ω ±5 Ω (f = 100 MHz)
Working capacitance≤ 65 pF (Line-line)
Working capacitance≤ 100 pF (Line-shield)
Nominal voltage, cable300 V AC
Test voltage2000 V AC (50 Hz, 5 minutes)
Minimum bending radius, fixed installation6 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation44 mm
Smallest bending radius, movable installation73 mm
Near end crosstalk attenuation (NEXT)80 dB (with 1 MHz)
Near end crosstalk attenuation (NEXT)76 dB (at 4 МHz)
Near end crosstalk attenuation (NEXT)67 dB (at 10 MHz)
Near end crosstalk attenuation (NEXT)60 dB (at 31.5 МHz)
Near end crosstalk attenuation (NEXT)56 dB (at 62.5 МHz)
Near end crosstalk attenuation (NEXT)53 dB (at 100 MHz)
Return attenuation (RL)35 dB (at 4 МHz)
Return attenuation (RL)35 dB (at 10 MHz)
Return attenuation (RL)35 dB (at 31.5 МHz)
Return attenuation (RL)33 dB (at 62.5 МHz)
Return attenuation (RL)33 dB (at 100 MHz)
Remote crosstalk attenuation (FEXT)80 dB (with 1 MHz)
Remote crosstalk attenuation (FEXT)70 dB (at 4 МHz)
Remote crosstalk attenuation (FEXT)65 dB (at 10 MHz)
Remote crosstalk attenuation (FEXT)58 dB (at 31.5 МHz)
Remote crosstalk attenuation (FEXT)59 dB (at 62.5 МHz)
Remote crosstalk attenuation (FEXT)67 dB (at 100 MHz)
Shield attenuation2 dB (with 1 MHz)
Shield attenuation4 dB (at 4 МHz)
Shield attenuation6.5 dB (at 10 MHz)
Shield attenuation10.5 dB (at 31.5 МHz)
Shield attenuation14 dB (at 62.5 МHz)
Shield attenuation18 dB (at 100 MHz)
Shield attenuation40.00 dB (30 MHz ≤ f ≤ 100 MHz)
Halogen-freein accordance with EN 50267-2-1
Flame resistanceEN 60332-1-2
Flame resistanceEN 50266
Flame resistanceEN 60332-3-25
Flame resistanceNF C32-070, 2.1
Flame resistanceNF C32-070, 2.2
Flame resistanceUL 1685, 12 (FT4)
Flame resistancein accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Fume corrosivenessEN 50267-2-2
Fume toxicityBS 6853 B.1
Fume toxicityEN 50305, 9.2
Concentration of fumesBS 6853 D.8.7
Concentration of fumesEN 61034-2
Concentration of fumesUL 1685, 12 (FT4)
Resistance to Oilaccording to IRM 902, 72 h at 100 °C
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
Fire protection in rail vehiclesGM/RT 2130 (Category Ia, Ib, II)
Fire protection in rail vehiclesEN 45545 (Risk level HL1 - HL3)
Fire protection in rail vehiclesDIN 5510 (Fire protection level 1, 2, 3, 4)
Fire protection in rail vehiclesNF F16-101 (Category A1, A2, B)
Fire protection in rail vehiclesNF F16-101 (Class C/F0)
Fire protection in rail vehiclesNFPA 130
Fire protection in rail vehiclesUNI CEI 11170 (Risk level LR1 - LR4)
Other resistanceResistance to fuels (according to IRM 903, 168 h at 70 °C)
Ambient Temperature (Operation)-50 °C ... 90 °C (cable, fixed installation)
Ambient Temperature (Operation)-40 °C ... 90 °C (Cable, flexible installation)

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 90 °C (Plug / socket)
Ambient Temperature (Operation)-40 °C ... 90 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 90 °C (Cable, flexible installation)

Why Proax for Phoenix Contact 1543757?

Proax is an authorized distributor of Phoenix Contact 1543757 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability