Official Distributor
SKU
MPN
SAC-4P-M12MSD/ 1,7-936/DS ST5
Weight
0.206 kg
Series SAC-4P
SAC-4P-M12MSD/ 1,7-936/DS ST5 - Bus system cable
Bus system cable, PROFINET, 4-wired, shielded, halogen-free black RADOX® CKW S, straight plug on D-SUB, customer version
Technical Specifications
Product properties
Sensor Type | PROFINET |
Number of Positions | 4 |
No. of cable outlets | 1 |
Shielded | yes |
Coding | D |
Insulation characteristics
Overvoltage category | II |
Degree of pollution | 3 |
Interfaces
Bus system | PROFINET |
Signal type/category | PROFINET |
Electrical properties
Nominal voltage UN | 48 V AC |
Nominal voltage UN | 60 V DC |
Nominal current IN | 4 A |
Mechanical data
Insertion/withdrawal cycles | ≥ 100 |
Material specifications
Flammability rating according to UL 94 | V0 |
Seal material | NBR |
Material of grip body | TPU, hardly inflammable, self-extinguishing |
Contact Material | CuSn |
Contact surface material | Ni/Au |
Contact carrier material | PA 6.6 |
Material for screw connection | Zinc die-cast, nickel-plated |
Connection 1
Type | Plug straight M12 |
Number of Positions | 4 |
Coding type | D (Data) |
Cable/line
Cable Length | 1.7 m |
PROFINET RADOX® railway application CAT5 reinforced [936]
Cable weight | 81 g/m |
Number of Positions | 4 |
Shielded | yes |
Cable Type | PROFINET RADOX® railway application CAT5 reinforced [936] |
Conductor structure | 1x4xAWG22/7, SF/TQ |
Signal speed | 66 c |
Conductor structure signal line | 7x 0.25 mm |
AWG Signal Line | 22 |
Conductor Cross Section | 4x 0.34 mm² |
Wire diameter incl. insulation | 1.95 mm |
External Cable Diameter | 7.25 mm ±0.3 mm |
Outer sheath, material | PE-X |
External sheath, color | black RAL 9005 |
Conductor material | silver-plated Cu litz wires |
Material wire insulation | PE-X |
Single wire, color | white-blue, orange-yellow |
Thickness, outer sheath | ≥ 0.80 mm |
Overall twist | Star quad |
Optical shield covering | 100 % |
Max. conductor resistance | ≤ 54.4 Ω/km |
Coupling resistance | 200.00 mΩ/m (f ≤ 30 MHz) |
Wave impedance | 100 Ω ±5 Ω (f = 100 MHz) |
Working capacitance | ≤ 65 pF (Line-line) |
Working capacitance | ≤ 100 pF (Line-shield) |
Nominal voltage, cable | 300 V AC |
Test voltage | 2000 V AC (50 Hz, 5 minutes) |
Minimum bending radius, fixed installation | 6 x D |
Minimum bending radius, flexible installation | 10 x D |
Smallest bending radius, fixed installation | 44 mm |
Smallest bending radius, movable installation | 73 mm |
Near end crosstalk attenuation (NEXT) | 80 dB (with 1 MHz) |
Near end crosstalk attenuation (NEXT) | 76 dB (at 4 МHz) |
Near end crosstalk attenuation (NEXT) | 67 dB (at 10 MHz) |
Near end crosstalk attenuation (NEXT) | 60 dB (at 31.5 МHz) |
Near end crosstalk attenuation (NEXT) | 56 dB (at 62.5 МHz) |
Near end crosstalk attenuation (NEXT) | 53 dB (at 100 MHz) |
Return attenuation (RL) | 35 dB (at 4 МHz) |
Return attenuation (RL) | 35 dB (at 10 MHz) |
Return attenuation (RL) | 35 dB (at 31.5 МHz) |
Return attenuation (RL) | 33 dB (at 62.5 МHz) |
Return attenuation (RL) | 33 dB (at 100 MHz) |
Remote crosstalk attenuation (FEXT) | 80 dB (with 1 MHz) |
Remote crosstalk attenuation (FEXT) | 70 dB (at 4 МHz) |
Remote crosstalk attenuation (FEXT) | 65 dB (at 10 MHz) |
Remote crosstalk attenuation (FEXT) | 58 dB (at 31.5 МHz) |
Remote crosstalk attenuation (FEXT) | 59 dB (at 62.5 МHz) |
Remote crosstalk attenuation (FEXT) | 67 dB (at 100 MHz) |
Shield attenuation | 2 dB (with 1 MHz) |
Shield attenuation | 4 dB (at 4 МHz) |
Shield attenuation | 6.5 dB (at 10 MHz) |
Shield attenuation | 10.5 dB (at 31.5 МHz) |
Shield attenuation | 14 dB (at 62.5 МHz) |
Shield attenuation | 18 dB (at 100 MHz) |
Shield attenuation | 40.00 dB (30 MHz ≤ f ≤ 100 MHz) |
Halogen-free | in accordance with EN 50267-2-1 |
Flame resistance | EN 60332-1-2 |
Flame resistance | EN 50266 |
Flame resistance | EN 60332-3-25 |
Flame resistance | NF C32-070, 2.1 |
Flame resistance | NF C32-070, 2.2 |
Flame resistance | UL 1685, 12 (FT4) |
Flame resistance | in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01) |
Fume corrosiveness | EN 50267-2-2 |
Fume toxicity | BS 6853 B.1 |
Fume toxicity | EN 50305, 9.2 |
Concentration of fumes | BS 6853 D.8.7 |
Concentration of fumes | EN 61034-2 |
Concentration of fumes | UL 1685, 12 (FT4) |
Resistance to Oil | according to IRM 902, 72 h at 100 °C |
Fire protection in rail vehicles | BS 6853 (Category Ia, Ib, II) |
Fire protection in rail vehicles | GM/RT 2130 (Category Ia, Ib, II) |
Fire protection in rail vehicles | EN 45545 (Risk level HL1 - HL3) |
Fire protection in rail vehicles | DIN 5510 (Fire protection level 1, 2, 3, 4) |
Fire protection in rail vehicles | NF F16-101 (Category A1, A2, B) |
Fire protection in rail vehicles | NF F16-101 (Class C/F0) |
Fire protection in rail vehicles | NFPA 130 |
Fire protection in rail vehicles | UNI CEI 11170 (Risk level LR1 - LR4) |
Other resistance | Resistance to fuels (according to IRM 903, 168 h at 70 °C) |
Ambient Temperature (Operation) | -50 °C ... 90 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -40 °C ... 90 °C (Cable, flexible installation) |
Ambient conditions
Degree of Protection | IP65 |
Degree of Protection | IP67 |
Degree of Protection | IP68 |
Ambient Temperature (Operation) | -25 °C ... 90 °C (Plug / socket) |
Ambient Temperature (Operation) | -40 °C ... 90 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -25 °C ... 90 °C (Cable, flexible installation) |
Why Proax for Phoenix Contact 1564066?
Proax is an authorized distributor of Phoenix Contact 1564066 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 10 |
Recommended
- 1557222 - Network cable, PROFINET CAT5, 4-position, PE-X halogen-free, black RAL 9005, shielded (Plastic-coated aluminum foil, tinned copper braided shield), Plug straight M12, coding: D / IP65, on Plug straight M12, coding: D / IP65, cable length: 2 m, Product tested according to customer specification/rail application