Official Distributor
SKU
MPN
UT 6-TMC M 6A
Weight
0.064 kg
Series UT
UT 6-TMC M 6A - Thermomagnetic device circuit breaker
Thermal-magnetic circuit breaker, 1-pos., for DIN rail mounting
- Simple feed-in due to bridging capability using CLIPLINE complete accessories
- High system availability, thanks to easy resetting
- Quick and easy identification with large-area marking options
- The right device for every application, thanks to a nominal current range of 0.5 to 16 A
- Space savings of 30 % compared to miniature circuit breakers owing to the compact width of 12.3 mm
Technical Specifications
Product properties
Product family | UT 6-TMC |
Type | DIN rail module, one-piece |
Number of Positions | 1 |
Number of Connections | 2 |
Number of rows | 1 |
No. of channels | 1 |
Potentials | 1 |
Insulation characteristics
Overvoltage category | II |
Degree of pollution | 2 |
Electrical properties
Fuse type | Automatic device |
Maximum power dissipation for nominal condition | ≤ 1.51 VA |
General
Operating Voltage | 50 V AC ... 264 V AC (48 - 62 Hz) |
Operating Voltage | 5 V DC ... 30.8 V DC |
Rated voltage | 240 V AC (50/60 Hz) |
Rated voltage | 28 V DC |
Rated voltage | 240 V AC (50/60 Hz) |
Rated voltage | 28 V DC |
Rated insulation voltage Ui | 440 V AC |
Rated current IN | 6 A |
Rated surge voltage | 2.8 kV |
Insulation resistance Riso | > 100 MΩ (main contact) |
Type of actuation | S type |
Tripping method | TM (thermomagnetic) |
Tripping level | Trip-free mechanism (positive) |
Device resistance | 41.7 mΩ |
Required backup fuse | 20 A |
Rated short-circuit switching capacity Icn | 200 A (240 V AC) |
Rated short-circuit switching capacity Icn | 400 A (28 V DC) |
Dielectric strength | 2000 V |
Switching cycles, max. | 6000 (at 1 x In) |
Switching cycles, max. | 50 (at 1.5 x In) |
Switching cycles, max. | 40 (at 6 x In) |
Fuse | M1 (normal blow) |
Power dissipation | ≤ 1.51 VA |
Temperature derating | 4.2 A DC (at -30 °C) |
Temperature derating | 4.38 A DC (at -20 °C) |
Temperature derating | 4.68 A DC (at -10 °C) |
Temperature derating | 5.04 A DC (at 0 °C) |
Temperature derating | 5.4 A DC (at 10 °C) |
Temperature derating | 6 A DC (at 23 °C) |
Temperature derating | 6.18 A DC (at 30 °C) |
Temperature derating | 6.48 A DC (at 40 °C) |
Temperature derating | 6.9 A DC (at 50 °C) |
Temperature derating | 7.26 A DC (at 60 °C) |
Indicator/remote signaling
Connection name | Auxiliary contact |
Connection data
Nominal cross section | 6.00 mm² |
Rated cross section AWG | 8 |
Connection Method | Screw connection |
Level 1 above 1 below 1
Screw thread | M4 |
Tightening torque | 1.5 ... 1.8 Nm |
Stripping length | 12 mm |
Conductor cross section rigid | 0.2 mm² ... 10 mm² |
Cross section AWG | 24 ... 8 (converted acc. to IEC) |
Conductor cross section flexible | 0.2 mm² ... 10 mm² |
Conductor cross section, flexible [AWG] | 24 ... 8 (converted acc. to IEC) |
Conductor cross-section flexible (ferrule without plastic sleeve) | 0.25 mm² ... 6 mm² |
Flexible conductor cross section (ferrule with plastic sleeve) | 0.25 mm² ... 6 mm² |
2 conductors with same cross section, solid | 0.2 mm² ... 2.5 mm² |
2 conductors with same cross section, flexible | 0.2 mm² ... 2.5 mm² |
2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² |
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 4 mm² |
Nominal Current | 6 A |
Nominal Voltage | 240 V AC |
Nominal Voltage | 28 V DC |
Nominal cross section | 6 mm² |
Main contact
Connection Method | Screw connection |
Screw thread | M4 |
Tightening torque | 1.5 Nm ... 1.8 Nm |
Stripping length | 12 mm |
Conductor cross section flexible | 0.2 mm² ... 10 mm² |
Conductor cross section rigid | 0.2 mm² ... 10 mm² |
Conductor cross section AWG | 24 ... 8 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 6 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 6 mm² |
Dimensions
Width | 12.3 mm |
Height | 85.5 mm |
Depth | 89.5 mm |
Material specifications
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V-0 |
Insulating material | PA66 |
Mechanical data
Open side panel | No |
Ambient conditions
Degree of Protection | IP40 (Actuation area) |
Degree of Protection | IP20 (Connection area) |
Ambient Temperature (Operation) | -30 °C ... 60 °C |
Altitude | 2000 m (acc. to EN 60934) |
Standards and Regulations
Standards/specifications | EN 60934 |
Standards/specifications | UL 1077 |
Standards/specifications | CSA 22.2 |
Note | No. 235 |
Standards/specifications | EAC |
Mounting
Mounting Type | DIN rail: 35 mm |
Accessories
Why Proax for Phoenix Contact 0916608?
Proax is an authorized distributor of Phoenix Contact 0916608 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 6 |
Recommended
- 3073869 - Disconnect terminal block, Current and voltage are determined by the plug used., With test socket screws for insertion of test plugs, nom. voltage: 500 V, nominal current: 20 A, connection method: Screw connection, Rated cross section: 6 mm2, cross section: 0.2 mm2 - 10 mm2, mounting: NS 35/7,5, NS 35/15, color: gray
- 3073870 - Disconnect terminal block, Current and voltage are determined by the plug used., With test socket screws for insertion of test plugs, nom. voltage: 500 V, nominal current: 20 A, connection method: Screw connection, Rated cross section: 2.5 mm2, cross section: 0.2 mm2 - 10 mm2, mounting: NS 35/7,5, NS 35/15, color: gray
- 3073872 - Disconnect terminal block, Current and voltage are determined by the plug used., With test socket screws for insertion of test plugs, nom. voltage: 500 V, nominal current: 20 A, connection method: Screw connection, Rated cross section: 2.5 mm2, cross section: 0.2 mm2 - 10 mm2, mounting: NS 35/7,5, NS 35/15, color: blue
- 3060584 - Ground terminal, The max. load current must not be exceeded by the total current of all connected conductors.Current and voltage are determined by the plug used., number of connections: 4, connection method: Screw/plug-in connection, cross section: 0.2 mm2 - 10 mm2, mounting type: NS 35/7,5, NS 35/15, color: green-yellow