UT 6-TMC M 2A - Thermomagnetic device circuit breaker
Thermal-magnetic circuit breaker, 1-pos., for DIN rail mounting
- Simple feed-in due to bridging capability using CLIPLINE complete accessories
- High system availability, thanks to easy resetting
- Quick and easy identification with large-area marking options
- The right device for every application, thanks to a nominal current range of 0.5 to 16 A
- Space savings of 30 % compared to miniature circuit breakers owing to the compact width of 12.3 mm
UT
The Phoenix Contact UT Series comprises feed-through terminal blocks that utilize screw connection technology, offering reliable and maintenance-free conductor connections for various industrial applications. These terminal blocks are designed to accommodate a wide range of conductor cross-sections, providing flexibility and ease of installation.
Key Features:
- ✅ Screw Connection Technology: The UT Series employs a screw connection method, ensuring secure and durable connections. The Reakdyn principle, a screw locking technique developed by Phoenix Contact, prevents loosening of terminal block screws, eliminating the need for retightening.
- ✅ Versatile Conductor Accommodation: These terminal blocks can connect solid and stranded conductors without ferrules, even above the nominal cross-section, due to their large wiring space. This feature allows for universal application across various conductor types and sizes.
- ✅ Compact Design: The UT Series offers a compact, space-saving design, making it ideal for smaller control cabinets and boxes where space is at a premium.
Product properties
Product family | UT 6-TMC |
Type | DIN rail module, one-piece |
Number of Positions | 1 |
Number of Connections | 2 |
Number of rows | 1 |
No. of channels | 1 |
Potentials | 1 |
Insulation characteristics
Overvoltage category | II |
Degree of pollution | 2 |
Electrical properties
Fuse type | Automatic device |
Maximum power dissipation for nominal condition | ≤ 1.32 VA |
General
Operating Voltage | 50 V AC ... 264 V AC (48 - 62 Hz) |
Operating Voltage | 5 V DC ... 30.8 V DC |
Rated voltage | 240 V AC (50/60 Hz) |
Rated voltage | 28 V DC |
Rated voltage | 240 V AC (50/60 Hz) |
Rated voltage | 28 V DC |
Rated insulation voltage Ui | 440 V AC |
Rated current IN | 2 A |
Rated surge voltage | 2.8 kV |
Insulation resistance Riso | > 100 MΩ (main contact) |
Type of actuation | S type |
Tripping method | TM (thermomagnetic) |
Tripping level | Trip-free mechanism (positive) |
Device resistance | 330 mΩ |
Required backup fuse | 16 A |
Rated short-circuit switching capacity Icn | 200 A (240 V AC) |
Rated short-circuit switching capacity Icn | 400 A (28 V DC) |
Dielectric strength | 2000 V |
Switching cycles, max. | 6000 (at 1 x In) |
Switching cycles, max. | 50 (at 1.5 x In) |
Switching cycles, max. | 40 (at 6 x In) |
Fuse | M1 (normal blow) |
Power dissipation | ≤ 1.32 VA |
Temperature derating | 1.54 A DC (at -30 °C) |
Temperature derating | 1.62 A DC (at -20 °C) |
Temperature derating | 1.68 A DC (at -10 °C) |
Temperature derating | 1.74 A DC (at 0 °C) |
Temperature derating | 1.8 A DC (at 10 °C) |
Temperature derating | 2 A DC (at 23 °C) |
Temperature derating | 2.06 A DC (at 30 °C) |
Temperature derating | 2.16 A DC (at 40 °C) |
Temperature derating | 2.3 A DC (at 50 °C) |
Temperature derating | 2.42 A DC (at 60 °C) |
Indicator/remote signaling
Connection name | Auxiliary contact |
Connection data
Nominal cross section | 6.00 mm² |
Rated cross section AWG | 8 |
Connection Method | Screw connection |
Level 1 above 1 below 1
Screw thread | M4 |
Tightening torque | 1.5 ... 1.8 Nm |
Stripping length | 12 mm |
Conductor cross section rigid | 0.2 mm² ... 10 mm² |
Cross section AWG | 24 ... 8 (converted acc. to IEC) |
Conductor cross section flexible | 0.2 mm² ... 10 mm² |
Conductor cross section, flexible [AWG] | 24 ... 8 (converted acc. to IEC) |
Conductor cross-section flexible (ferrule without plastic sleeve) | 0.25 mm² ... 6 mm² |
Flexible conductor cross section (ferrule with plastic sleeve) | 0.25 mm² ... 6 mm² |
2 conductors with same cross section, solid | 0.2 mm² ... 2.5 mm² |
2 conductors with same cross section, flexible | 0.2 mm² ... 2.5 mm² |
2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² |
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 4 mm² |
Nominal Current | 2 A |
Nominal Voltage | 240 V AC |
Nominal Voltage | 28 V DC |
Nominal cross section | 6 mm² |
Main contact
Connection Method | Screw connection |
Screw thread | M4 |
Tightening torque | 1.5 Nm ... 1.8 Nm |
Stripping length | 12 mm |
Conductor cross section flexible | 0.2 mm² ... 10 mm² |
Conductor cross section rigid | 0.2 mm² ... 10 mm² |
Conductor cross section AWG | 24 ... 8 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 6 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 6 mm² |
Dimensions
Width | 12.3 mm |
Height | 85.5 mm |
Depth | 89.5 mm |
Material specifications
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V-0 |
Insulating material | PA66 |
Mechanical data
Open side panel | No |
Ambient conditions
Degree of Protection | IP40 (Actuation area) |
Degree of Protection | IP20 (Connection area) |
Ambient Temperature (Operation) | -30 °C ... 60 °C |
Altitude | 2000 m (acc. to EN 60934) |
Standards and Regulations
Standards/specifications | EN 60934 |
Standards/specifications | UL 1077 |
Standards/specifications | CSA 22.2 |
Note | No. 235 |
Standards/specifications | EAC |
Mounting
Mounting Type | DIN rail: 35 mm |
Why Proax for Phoenix Contact 0916605?
Proax is an authorized distributor of Phoenix Contact 0916605 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Pack Size | 6 |
- UT 6-TG P/P-EX - Disconnect terminal block, Current and voltage are determined by the plug used., With test socket screws for insertion of test plugs, nom. voltage: 500 V, nominal current: 20 A, connection method: Screw connection, Rated cross section: 2.5 mm2, cross section: 0.2 mm2 - 10 mm2, mounting: NS 35/7,5, NS 35/15, color: gray
- UT 6-TG P/P - Disconnect terminal block, Current and voltage are determined by the plug used., With test socket screws for insertion of test plugs, nom. voltage: 500 V, nominal current: 20 A, connection method: Screw connection, Rated cross section: 6 mm2, cross section: 0.2 mm2 - 10 mm2, mounting: NS 35/7,5, NS 35/15, color: gray
- UT 6-TG P/P BU - Disconnect terminal block, Current and voltage are determined by the plug used., With test socket screws for insertion of test plugs, nom. voltage: 500 V, nominal current: 20 A, connection method: Screw connection, Rated cross section: 2.5 mm2, cross section: 0.2 mm2 - 10 mm2, mounting: NS 35/7,5, NS 35/15, color: blue
- UT 6-QUATTRO/2P-PE - Ground terminal, The max. load current must not be exceeded by the total current of all connected conductors.Current and voltage are determined by the plug used., number of connections: 4, connection method: Screw/plug-in connection, cross section: 0.2 mm2 - 10 mm2, mounting type: NS 35/7,5, NS 35/15, color: green-yellow