SKU
MPN
PSR-M-B2-SDI8-SDO4-DO4-PI
Weight
0.182 kg
This product is Not Cancellable/Not Returnable
Series PSR-M-B
PSR-M-B2-SDI8-SDO4-DO4-PI - Safety module
Configurable safety module (basic module), 8 safe inputs, 4 safe outputs, 4 reset inputs or 4 signal outputs, 4 clock outputs, can be extended via TBUS, up to SIL 3, Cat. 4/PL e, plug-in Push-in terminal block, TBUS connector not included
- Cost-effective safety solution with a high level of adaptability to individual requirements
- Fast startup, thanks to easy hardware and software configuration
- Machine downtimes minimized with comprehensive, easy-to-understand diagnostics
- Flexible extension with safe inputs and outputs
- Possibility of connecting fieldbus gateways for bidirectional communication between the base module and the higher-level controller
- Narrow housing width of just 22.6 mm
- Tool-free and time-saving installation thanks to Push-in technology
- Up to Cat. 4/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
- Suitable for elevator applications in accordance with EN 81-20
Technical Specifications
Product properties
Application | Emergency stop |
Application | Light grid |
Application | Safety door |
Application | Safe shutdown |
Insulation characteristics
Protection class | III (EN 50178) |
Times
Response time | see user manual |
Restart time | min. 5 s (Boot time) |
Restart time | max. 10 s (Boot time) |
Electrical properties
Maximum power dissipation for nominal condition | 7.1 W (with max. permissible load) |
Nominal operating mode | 100% operating factor |
Interfaces | DIN rail TBUS for connection to the master module, not supplied as standard |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 250 V AC |
Rated surge voltage/insulation | Basic insulation 4 kV between all current paths and housing |
Supply
Designation | A1/A2 |
Rated control circuit supply voltage US | 19.2 V DC ... 28.8 V DC |
Rated control circuit supply voltage US | 24 V DC -20 % / +20 % (provide external protection, typically 5 A) |
Rated control supply current IS | typ. 55 mA (Outputs inactive) |
Rated control supply current IS | typ. 135 mA (Outputs active, without load) |
Power consumption at US | typ. 1.32 W (Outputs inactive) |
Inrush Current | < 2.3 A (Δt = 1 ms at Us) |
Filter time | typ. 5 ms (at A1 in the event of voltage dips at Us) |
Protective circuit | Serial protection against polarity reversal |
Digital: IN1, IN2, IN3, IN4, IN5, IN6, IN7, IN8
Description of the input | Safety-related digital inputs |
Description of the input | IEC 61131-2 type 2 |
Number of Inputs | 8 |
Input voltage range "0" signal | 0 V DC ... 5 V DC |
Input voltage range "1" signal | 11 V DC ... 28.8 V DC |
Input current range "0" signal | < 1 mA |
Filter time | min. 3 ms ±2 ms (adjustable) |
Filter time | max. 250 ms ±2 ms (adjustable) |
Filter time | Test pulse rate ≥ 2x set filter time, min. Test pulse rate = 10 ms |
Cable Length | max. 100 m (per input) |
Max. permissible overall conductor resistance | max. 1.2 kΩ (Input and reset circuit at US) |
Current consumption | typ. 10 mA (typically with US) |
Current consumption | max. 12.1 mA (at a control voltage of 28.8 V DC) |
Digital: Reset inputs (FBK)
Description of the input | configurable (as signal output or reset input) |
Description of the input | IEC 61131-2 Type 2 |
Number of Inputs | 4 |
Input voltage range "0" signal | 0 V DC ... 5 V DC |
Input voltage range "1" signal | 11 V DC ... 28.8 V DC |
Input current range "0" signal | < 1 mA |
Filter time | 250 ms ±2 ms (Test pulse rate > 500 ms) |
Cable Length | max. 100 m (per input) |
Max. permissible overall conductor resistance | 1.2 kΩ (Input and reset circuit at US) |
Current consumption | typ. 12 mA (typically with US) |
Current consumption | max. 14.7 mA (at a control voltage of 28.8 V DC) |
Digital: O1, O2, O3, O4
Output description | Safety-related digital outputs |
Output description | PNP, OSSD |
Output description | IEC 61131-2 type 0.5 (observe limiting continuous current) |
Number of Outputs | 4 |
Protective circuit | Suppressor diode |
Short-circuit protection | Yes (max. permissible short-circuit current 12 A) |
Leakage current | max. 250 µA |
Cable Length | max. 100 m (per output) |
Ohmic load | min. 50 Ω (Observe limiting continuous current) |
Max. capacitive load | max. 820 nF |
Max. inductive load | max. 2.4 mH |
Limiting Continuous Current | 400 mA (per channel) |
Limiting Continuous Current | 1.6 A (Total current of all safe digital outputs) |
Inrush Current | max. 600 mA (Δt < 10 ms) |
Nominal Output Voltage | 24 V DC (Supply via A1) |
Nominal output voltage range | 18.5 V DC ... 28.1 V DC (US - 0,7 V) |
Switching frequency | max. 1/4 x tCycle [Hz] |
Output voltage when switched off | < 0.1 V |
Test pulses | < 120 µs (Test pulse width of low test pulses) |
Test pulses | ≥ 650 ms (Test pulse rate for low test pulse) |
Test pulses | < 150 µs (Test pulse width, high test pulse) |
Test pulses | ≥ 1.5 s (Test pulse rate, high test pulse) |
Discharging circuit | Yes, internal |
Signal: MO1, MO2, MO3, MO4
Output description | PNP, IEC 61131-2 Typ 0,1 |
Output description | non-safety-related, configurable (as signal output or reset input) |
Number of Outputs | 4 |
Output voltage when switched off | max. 0.1 V |
Voltage | 24 V DC (via A1) |
Maximum Inrush Current | 1.1 A (Δt = 3 s at Us) |
Limiting Continuous Current | 100 mA (per channel) |
Limiting Continuous Current | 400 mA (Total current of all digital signal outputs) |
Leakage current | max. 100 µA |
Switching frequency | max. 1/4 x tCycle [Hz] |
Protective circuit | Suppressor diode |
Short-circuit protection | Yes (self-limitation at 1.1 A) |
Cable Length | max. 100 m (per output) |
Clock: T1, T2, T3, T4
Output description | PNP, IEC 61131-2 Typ 0,1 |
Number of Outputs | 4 |
Voltage | 24 V DC (via A1) |
Output voltage when switched off | max. 0.1 V |
Maximum Inrush Current | 1.1 A (Δt = 3 s at Us) |
Limiting Continuous Current | 100 mA (per channel) |
Limiting Continuous Current | 400 mA (Total current of all outputs) |
Leakage current | max. 100 µA |
Test pulses | ≤ 200 µs (Test pulse duration) |
Test pulses | Test pulse rate = 8 x tCycle [ms] |
Short-circuit protection | Yes (self-limitation at 1.1 A) |
Cable Length | max. 100 m (per output) |
Max. capacitive load | max. 470 nF |
Max. inductive load | max. 2.4 mH |
Discharging circuit | Yes, internal |
Connection technology
pluggable | yes |
Conductor connection
Connection Method | Push-in connection |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross-section AWG | 24 ... 14 |
Stripping length | 10 mm |
Signaling
Status display | 1 x LED (green), 1 x LED (orange), 1 x LED (blue) |
Status display | 4 x LED (green, yellow, red) |
Status display | 12 x LED (yellow) |
Operating voltage display | 1 x green LED |
Error indication | 2 x LED (red) |
Dimensions
Width | 22.61 mm |
Height | 107.74 mm |
Depth | 113.6 mm |
Material specifications
Color (Housing) | yellow (RAL 1018) |
Housing Material | Polyamide PA non-reinforced |
Safety data
Stop category | 0 |
Safety data: EN ISO 13849
Performance level (PL) | e (2-channel wiring) |
Performance level (PL) | d (1-channel wiring) |
Safety data: IEC 61508 - High-demand for 2-channel wiring
Safety Integrity Level (SIL) | 3 |
Safety data: IEC 61508 - High-demand for 1-channel wiring
Safety Integrity Level (SIL) | 2 |
Safety data: EN IEC 62061
Safety Integrity Level (SIL) | 3 (2-channel wiring) |
Safety Integrity Level (SIL) | 2 (1-channel wiring) |
Ambient conditions
Degree of Protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient Temperature (Operation) | -10 °C ... 55 °C (observe derating) |
Ambient temperature (storage/transport) | -20 °C ... 85 °C |
Maximum altitude | ≤ 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 95 % (non-condensing) |
Max. permissible relative humidity (operation) | 95 % (non-condensing) |
Shock | 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction) |
Vibration (Operation) | 10 Hz ... 150 Hz, 2g |
CE
Identification | CE-compliant |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | Observe derating |
Mounting Position | vertical or horizontal |
Accessories
- ME 22,5 TBUS 1,5/ 5-ST-3,81 YE - DIN rail connector, color: yellow, nominal current: 8 A (parallel contacts), rated voltage (III/2): 125 V, number of positions: 5, product range: TBUS5-22,5.., pitch: 3.81 mm, mounting: DIN rail mounting, locking: without, mounting: without, type of packaging: packed in cardboard, Item with gold-plated contacts, bus connectors for connecting with electronics housings, 5 parallel contacts
Why Proax for Phoenix Contact 1104975?
Proax is an authorized distributor of Phoenix Contact 1104975 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |