Series STEP-UPS

STEP-UPS/24DC/24DC/3/46WH - Uninterruptible power supply

Uninterruptible power supply with integrated battery. The STEP-BAT/LI-ION/18.5DC/46WH battery can be re-ordered separately.

  • Stable supply of sensitive loads, thanks to the regulated output voltage
  • Safety ensured, thanks to the integrated protective circuit and energy storage temperature monitoring
  • Quick and easy installation with integrated battery
  • Battery operation can be stopped via remote contact
  • Flexible assembly – can be snapped onto the DIN rail or screwed onto a level surface
Technical Specifications

General

Note on the batteryThis product contains a battery with a limited shelf life that must be charged every few months. The product packaging indicates when the battery must be started up or recharged. The general shelf life can be found in the technical data area under “Latest startup”.

DC operation

Input Voltage24 V DC
Input voltage range22.5 V DC ... 29.5 V DC
Voltage type of supply voltageDC
Buffer period90 min. (1 A)
Buffer period45 min. (2 A)
Buffer period30 min. (3 A)
Buffer period22 min. (4 A)
Rotary selector switchService
Rotary selector switch
Rotary selector switch5 min.
Rotary selector switch10 min.
Rotary selector switch20 min.
Current consumption4.7 A (max.)
Current consumption< 30 mA (No-load)
Current consumption< 0.5 A (Charging (ICharge = max, IOut = 0))
Fixed backup threshold< 22.5 V
Variable connect threshold1 V / 1 s
Typical response time< 0.5 s
Input fuse7 A (slow-blow, internal)

Output data

Efficiency> 98 % (for charged battery)
Efficiency> 95 % (Battery operation)
Nominal Output Voltage24 V DC
Nominal output current (IN)3 A (0 °C ... 40 °C)
Output current limitIn mains mode according to connected upstream current limiting device
Output current limit> 4 A (Battery operation)
POWER BOOST (IBoost)4 A (0 °C ... 35 °C)
Bridging time900 s
Derating35 °C ... 40 °C (5 %/K)
Output Power72 W
Power dissipation0.6 W (No-load)
Power dissipation2 W (Nominal load)
Power dissipation4.4 W (Imax)
Power dissipation1.1 W (No-load)
Power dissipation3.8 W (Nominal load)
Power dissipation10 W (Imax)
Connection in seriesNo

Mains operation

Nominal Output Voltage24 V DC
Output voltage rangeUOut = UIn - 0.3 V DC
Nominal output current (IN)3 A (0 °C ... 40 °C)

Battery operation

Nominal Output Voltage24 V DC
Output voltage range23 V DC ... 26.5 V DC ()
Nominal output current (IN)3 A (0 °C ... 40 °C)

Signal: Alarm

Output descriptionTransistor

Signal: Battery charge

Output descriptionTransistor

Signal: Battery mode

Output descriptionTransistor

Energy storage

Nominal voltage UN18.5 V DC
End-of-charge voltage18.5 V DC ... 21 V DC
Charging current0.4 A
Nominal capacity46 Wh
Charging timemax. 5.5 h
Deep discharge protection< 15 V DC
Latest startup date (battery only)12 Months (25 °C)
Battery technologyLithium-ion
Memory mediumLithium-ion
Battery presence check (cyclic)60 s
Quality check of batteryyes, with each charge and cyclically once per month
IQ Technologyno

Input

Connection MethodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.2.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length6.5 mm
Screw threadM3
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Output

Connection MethodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.2.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length6.5 mm
Screw threadM3
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Signal

Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.2.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length6.5 mm
Screw threadM3
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Signaling

Types of signalingLED

Signal output

Signalization designationPower In OK
Status displayLED
Note on status displaystatic on

Signal output: Switching output

Signalization designationAlarm
Status displayLED
Note on status displaystatic on
Signalization designationBattery charge
Status displayLED
Note on status displayflashing
Signalization designationBattery mode
Status displayLED
Note on status displaystatic on

Signal output

Signalization designationOverload
Status displayLED
Note on status displayflashing
Signalization designationService/Battery Error
Status displayLED
Note on status displayflashing

Product properties

Product familySTEP UPS ‒ UPS with integrated battery
IQ Technologyno
MTBF (IEC 61709, SN 29500)> 1401000 h (40 °C)

Insulation characteristics

Protection classIII
Degree of pollution2

Dimensions

Width108 mm
Height90 mm
Depth71 mm

Installation dimensions

Installation distance right/left0 mm / 0 mm
Installation distance top/bottom30 mm / 30 mm

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsalignable: horizontally 0 mm, vertically 50 mm
Mounting Positionhorizontal DIN rail NS 35, EN 60715

Material specifications

Housing MaterialPlastic
Housing MaterialPolycarbonate
Type of housingPlastic
Foot latch materialPOM (Polyoxymethylene)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)0 °C ... 40 °C
Ambient temperature (storage/transport)-20 °C ... 45 °C
Maximum altitudemax. 2000 m
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Vibration (Operation)15 Hz ... 150 Hz, 2.3g, 90 min.

Standards and Regulations

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard - Electrical safetyIEC 62368-1 (SELV)

Approvals

UL approvalsUL/C-UL listed UL 508
UL approvalsUL/C-UL Recognized UL 60950-1

EMC data

EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge6 kV (Test Level 3)
Discharge in air8 kV (Test Level 3)
CommentsCriterion A

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 1 GHz
Test field strength10 V/m (Test Level 3)
Frequency Range1 GHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input2 kV (Test Level 3 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal2 kV (Test Level 4 - asymmetrical)
CommentsCriterion A

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input0.5 kV (Test Level 1 - symmetrical)
Input0.5 kV (Test Level 1 - asymmetrical)
Output0.5 kV (Test Level 1 - symmetrical)
Output0.5 kV (Test Level 1 - asymmetrical)
Signal1 kV (Test Level 2 - asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
I/O/Sasymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)

Emitted interference

Standards/regulationsEN 61000-6-3
Radio interference voltage in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Accessories

Why Proax for Phoenix Contact 1081430?

Proax is an authorized distributor of Phoenix Contact 1081430 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability