Official Distributor
SKU
MPN
STEP-PS/ 1AC/15DC/4
Weight
0.311 kg
This product is Not Cancellable/Not Returnable
Series STEP-PS
STEP-PS/ 1AC/15DC/4 - Power supply unit
Primary-switched STEP POWER power supply for DIN rail mounting, input: 1-phase, output: 15 V DC/4 A
- Flexible mounting by simply snapping onto the DIN rail or screwing onto a level surface
- Reliable power supply thanks to high MTBF (mean time between failures) of more than 500,000 hours and U/I characteristic curve
- Energy savings thanks to maximum energy efficiency and incredibly low idling losses
Technical Specifications
AC operation
Nominal input voltage range | 100 V AC ... 240 V AC |
Input voltage range | 85 V AC ... 264 V AC |
Input voltage range | 95 V DC ... 250 V DC |
Input Voltage Range AC | 85 V AC ... 264 V AC |
Input voltage range DC | 95 V DC ... 250 V DC |
Voltage type of supply voltage | AC/DC |
Inrush Current | < 15 A (typical) |
Inrush current integral (I2t) | < 0.6 A2s |
AC frequency range | 45 Hz ... 65 Hz |
Frequency range DC | 0 Hz |
Mains buffering time | typ. 27 ms (120 V AC) |
Mains buffering time | typ. 120 ms (230 V AC) |
Current consumption | 0.8 A (120 V AC) |
Current consumption | 0.5 A (230 V AC) |
Nominal Power Consumption | 118.1 VA |
Protective circuit | Transient surge protection; Varistor |
Power factor (cos phi) | 0.58 |
Typical response time | < 0.5 s |
Input fuse | 3.15 A (slow-blow, internal) |
Recommended breaker for input protection | 6 A ... 16 A (Characteristics B, C, D, K) |
Output data
Efficiency | > 87 % (for 230 V AC and nominal values) |
Output characteristic | U/I |
Nominal Output Voltage | 15 V DC |
Setting range of the output voltage (USet) | 10 V DC ... 16.5 V DC (> 15 V DC, constant capacity restricted) |
Output current Imax | 9 A |
Nominal output current (IN) | 4 A (-25 °C ... 55 °C) |
Nominal output current (IN) | 4.4 A (-25 °C ... 40 °C permanent) |
Derating | 55 °C ... 70 °C (2.5 %/K) |
Feedback voltage resistance | ≤ 25 V DC |
Protection against overvoltage at the output (OVP) | < 25 V DC |
Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
Control deviation | < 2 % (change in load, dynamic 10 % ... 90 %) |
Control deviation | < 0.1 % (change in input voltage ±10 %) |
Residual ripple | < 55 mVPP (20 MHz) |
Output Power | 60 W |
Peak switching voltages nominal load | < 10 mVPP (20 MHz) |
Maximum no-load power dissipation | < 0.5 W |
Power loss nominal load max. | 8.6 W |
Rise time | < 0.5 s (UOUT (10 % ... 90 %)) |
Connection in parallel | yes, for redundancy and increased capacity |
Connection in series | yes |
Input
Connection Method | Screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 6.5 mm |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Output
Connection Method | Screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 6.5 mm |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Signaling
Types of signaling | LED |
Operating voltage display | Green LED |
Signal output: LED status indicator
Status display | "DC OK" LED green |
Note on status display | UOUT > 10.8 V: LED on |
Electrical properties
Number of phases | 1.00 |
Insulation voltage input/output | 4 kV AC (type test) |
Insulation voltage input/output | 3.75 kV AC (routine test) |
Insulation voltage output / PE | 500 V DC (routine test) |
Insulation voltage input/output | 3.75 kV AC (routine test) |
Insulation voltage input/output | 4 kV AC (type test) |
Insulation voltage input / PE | 3.5 kV AC (type test) |
Insulation voltage input / PE | 2 kV AC (routine test) |
Product properties
Product family | STEP POWER |
MTBF (IEC 61709, SN 29500) | > 1134000 h (40 °C) |
Insulation characteristics
Protection class | II (in closed control cabinet) |
Overvoltage category | III |
Degree of pollution | 2 |
Dimensions
Width | 72 mm |
Height | 90 mm |
Depth Device depth (DIN rail mounting) | 55 mm (Device depth (DIN rail mounting)) |
Horizontal pitch | 4 Div. |
Installation dimensions
Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 30 mm / 30 mm |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | alignable: 0 mm horizontally, 30 mm vertically |
Mounting Position | horizontal DIN rail NS 35, EN 60715 |
With protective coating | No |
Material specifications
Housing Material | Plastic |
Housing Material | Polycarbonate |
Foot latch material | POM (Polyoxymethylene) |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C (> 55° C derating : 2.5%/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Climatic class | 3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (Operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
Vibration (Operation) | 15 Hz ... 150 Hz, 2.3g, 90 min. |
Standards and Regulations
Rail applications | EN 50121-4 |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
Standard - Electrical safety | IEC 62368-1 (SELV) |
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment | EN 50178 |
Standard – Safety extra-low voltage | IEC 62368-1 (SELV) und EN 60204-1 (PELV) |
Standard - Safe isolation | DIN VDE 0100-410 |
Standard - Safety of transformers | EN 61558-2-16 |
Approvals
CSA | CSA-C22.2 No. 107.1-01 |
Shipbuilding approval | DNV GL (EMC B) ABS, NK |
UL approvals | UL/C-UL listed UL 508 |
UL approvals | UL/C-UL Recognized UL 60950-1 |
UL approvals | UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T3C (Hazardous Location) |
Conformity/Approvals
SIL in accordance with IEC 61508 | 0 |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
EMC requirements for noise emission | EN 61000-6-3 |
EMC requirements for noise emission | EN 61000-6-4 |
EMC requirements for noise immunity | EN 61000-6-1 |
EMC requirements for noise immunity | EN 61000-6-2 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | 6 kV (Test Level 3) |
Discharge in air | 8 kV (Test Level 3) |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 1 GHz |
Test field strength | 10 V/m |
Frequency Range | 1 GHz ... 2 GHz |
Test field strength | 10 V/m |
Frequency Range | 2 GHz ... 3 GHz |
Test field strength | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | 4 kV (Test Level 4 - asymmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Comments | Criterion B |
Surge voltage load (surge)
Standards/regulations | EN 61000-4-5 |
Input | 1 kV (Test Level 2 - symmetrical) |
Input | 2 kV (Test Level 3 - asymmetrical) |
Output | 0.5 kV (Test Level 1 - symmetrical) |
Output | 0.5 kV (Test Level 1 - asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Frequency Range | 10 kHz ... 15 kHz |
Frequency Range | 10 kHz ... 15 kHz |
Comments | Criterion A |
Comments | Criterion A |
Voltage | 3 V (Test Level 2) |
Voltage | 3 V (Test Level 2) |
Frequency Range | 10 kHz ... 15 kHz |
Frequency Range | 10 kHz ... 15 kHz |
Comments | Criterion A |
Comments | Criterion A |
Voltage | 3 V (Test Level 2) |
Voltage | 3 V (Test Level 2) |
Voltage dips
Standards/regulations | EN 61000-4-11 |
Emitted interference
Standards/regulations | EN 61000-6-3 |
Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) class B used in industry and residential area / EMC 1 |
Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) class B used in industry and residential area / EMC 1 |
Accessories
Why Proax for Phoenix Contact 2868619?
Proax is an authorized distributor of Phoenix Contact 2868619 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended