Official Distributor
SKU
MPN
STEP-UPS/12DC/12DC/4/46WH
Weight
0.662 kg
This product is Not Cancellable/Not Returnable
Series STEP-UPS
STEP-UPS/12DC/12DC/4/46WH - Uninterruptible power supply
Uninterruptible power supply with integrated battery. The STEP-BAT/LI-ION/18.5DC/46WH battery can be re-ordered separately.
- Stable supply of sensitive loads, thanks to the regulated output voltage
- Safety ensured, thanks to the integrated protective circuit and energy storage temperature monitoring
- Quick and easy installation with integrated battery
- Battery operation can be stopped via remote contact
- Flexible assembly – can be snapped onto the DIN rail or screwed onto a level surface
Technical Specifications
General
Note on the battery | This product contains a battery with a limited shelf life that must be charged every few months. The product packaging indicates when the battery must be started up or recharged. The general shelf life can be found in the technical data area under “Latest startup”. |
DC operation
Input Voltage | 12 V DC |
Input voltage range | 10 V DC ... 16.5 V DC |
Voltage type of supply voltage | DC |
Buffer period | 180 min. (1 A) |
Buffer period | 90 min. (2 A) |
Buffer period | 60 min. (3 A) |
Buffer period | 45 min. (4 A) |
Rotary selector switch | Service |
Rotary selector switch | |
Rotary selector switch | 5 min. |
Rotary selector switch | 10 min. |
Rotary selector switch | 20 min. |
Current consumption | 6 A (max.) |
Current consumption | < 30 mA (No-load) |
Current consumption | < 0.8 A (Charging (ICharge = max, IOut = 0)) |
Fixed backup threshold | < 10 V |
Variable connect threshold | 1 V / 1 s |
Typical response time | < 0.5 s |
Input fuse | 7 A (slow-blow, internal) |
Maximum current Imax | 6 A |
Output data
Efficiency | > 97.4 % (for charged battery) |
Efficiency | > 92 % (Battery operation) |
Nominal Output Voltage | 12 V DC |
Nominal output current (IN) | 4 A (0 °C ... 40 °C) |
Output current limit | In mains mode according to connected upstream current limiting device |
Output current limit | > 5 A (Battery operation) |
POWER BOOST (IBoost) | 5 A (0 °C ... 35 °C) |
Bridging time | 1200 s |
Derating | 35 °C ... 40 °C (5 %/K) |
Output Power | 48 W |
Power dissipation | 0.4 W (Mains operation) |
Power dissipation | 1.2 W (Mains operation) |
Power dissipation | 5.5 W (Mains operation) |
Power dissipation | 1 W (Battery operation) |
Power dissipation | 4.4 W (Battery operation) |
Power dissipation | 5.4 W (Battery operation) |
Connection in series | No |
Mains operation
Nominal Output Voltage | 12 V DC |
Output voltage range | UOut = UIn - 0.3 V DC |
Nominal output current (IN) | 4 A (0 °C ... 40 °C) |
Battery operation
Nominal Output Voltage | 12 V DC |
Output voltage range | 10 V DC ... 15 V DC (UOut = UIn (t-1)) |
Nominal output current (IN) | 4 A (0 °C ... 40 °C) |
Signal: Alarm
Output description | Transistor |
Signal: Battery charge
Output description | Transistor |
Signal: Battery mode
Output description | Transistor |
Energy storage
Nominal voltage UN | 18.5 V DC |
End-of-charge voltage | 18.5 V DC ... 21 V DC |
Charging current | 0.4 A |
Nominal capacity | 46 Wh |
Charging time | 5.5 h (max.) |
Deep discharge protection | < 15 V DC |
Latest startup date (battery only) | 12 Months (25 °C) |
Battery technology | Lithium-ion |
Memory medium | Lithium-ion |
Battery presence check (cyclic) | 60 s |
Quality check of battery | yes, with each charge and cyclically once per month |
IQ Technology | no |
Input
Connection Method | Screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 6.5 mm |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Output
Connection Method | Screw connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 6.5 mm |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Signal
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 6.5 mm |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Signaling
Types of signaling | LED |
Signal output
Signalization designation | Power In OK |
Status display | LED |
Note on status display | static on |
Signal output: Switching output
Signalization designation | Alarm |
Status display | LED |
Note on status display | static on |
Signalization designation | Battery charge |
Status display | LED |
Note on status display | flashing |
Signalization designation | Battery mode |
Status display | LED |
Note on status display | static on |
Signal output
Signalization designation | Overload |
Status display | LED |
Note on status display | flashing |
Signalization designation | Service/Battery Error |
Status display | LED |
Note on status display | flashing |
Product properties
Product family | STEP UPS ‒ UPS with integrated battery |
IQ Technology | no |
MTBF (IEC 61709, SN 29500) | > 1997000 h (40 °C) |
Insulation characteristics
Protection class | III |
Degree of pollution | 2 |
Dimensions
Width | 108 mm |
Height | 90 mm |
Depth | 71 mm |
Installation dimensions
Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 30 mm / 30 mm |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm |
Mounting Position | horizontal DIN rail NS 35, EN 60715 |
Material specifications
Housing Material | Plastic |
Housing Material | Polycarbonate |
Type of housing | Plastic |
Foot latch material | POM (Polyoxymethylene) |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | 0 °C ... 40 °C |
Ambient temperature (storage/transport) | -20 °C ... 45 °C |
Climatic class | 3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (Operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
Vibration (Operation) | 15 Hz ... 150 Hz, 2.3g, 90 min. |
Standards and Regulations
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard - Electrical safety | IEC 62368-1 (SELV) |
Approvals
UL approvals | UL Listed UL 508 |
UL approvals | UL/C-UL Recognized UL 60950-1 |
EMC data
EMC requirements for noise immunity | EN 61000-6-2 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | 6 kV (Test Level 3) |
Discharge in air | 8 kV (Test Level 3) |
Comments | Criterion A |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 1 GHz |
Test field strength | 10 V/m (Test Level 3) |
Frequency Range | 1 GHz ... 2 GHz |
Test field strength | 10 V/m (Test Level 3) |
Frequency Range | 2 GHz ... 3 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | 2 kV (Test Level 3 - asymmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 2 kV (Test Level 4 - asymmetrical) |
Comments | Criterion A |
Surge voltage load (surge)
Standards/regulations | EN 61000-4-5 |
Input | 0.5 kV (Test Level 1 - symmetrical) |
Input | 0.5 kV (Test Level 1 - asymmetrical) |
Output | 0.5 kV (Test Level 1 - symmetrical) |
Output | 0.5 kV (Test Level 1 - asymmetrical) |
Signal | 1 kV (Test Level 2 - asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
I/O/S | asymmetrical |
Frequency Range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Emitted interference
Standards/regulations | EN 61000-6-3 |
Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Accessories
Why Proax for Phoenix Contact 1082548?
Proax is an authorized distributor of Phoenix Contact 1082548 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended