Official Distributor
SKU
MPN
AXC F IL ADAPT
Weight
0.116 kg
This product is Not Cancellable/Not Returnable
AXC F IL ADAPT - PLC extension module
Right-alignable Inline adapter terminal (INTERBUS master) for one PLCnext Control device for setting up a PLCnext Technology Inline station
- Automatic detection of the transmission speed in INTERBUS (500 kbps or 2 Mbps)
- Up to 63 INTERBUS local bus devices can be connected
- Diagnostic and status indicators
- Inline I/O adapter terminal specifically developed for all PLCnext Control devices of the Axiocontrol series
- A variety of functional I/Os creates options for flexible automation solutions
- Convert existing machines and systems to the new, open PLCnext Technology ecosystem
Technical Specifications
Dimensions
Width | 12.2 mm |
Height | 119.8 mm |
Depth | 71.5 mm |
Inline local bus
Number of interfaces | 1 |
Connection Method | Inline data jumper |
INTERBUS local bus (master)
Number of interfaces | 1 |
Connection Method | Inline data jumper |
Transmission physics | Copper |
System properties
Supported controllers | AXC F 2152 |
System limits
Number of local bus devices that can be connected | max. 63 (observe current consumption) |
Number of devices with parameter channel | max. 24 |
Number of supported branch terminals with remote bus branch | - 0 (INTERBUS remote bus not supported) |
Product properties
Product family | PLCnext Control Extension |
Type | modular |
Diagnostics messages | Bus error in INTERBUS yes |
Diagnostics messages | Peripheral fault in INTERBUS yes |
Electrical properties
Maximum power dissipation for nominal condition | 0.77 W |
Potentials
Protective circuit | Polarity reversal protection of the supply voltage; Polarity protection diode |
Protective circuit | Transient protection; Suppressor diode |
Potentials: 24 V supply UILC
Supply Voltage | 24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
Current draw | 20 mA |
Potentials: 7.5 V communications power UL (potential jumper)
Supply Voltage | 7.5 V DC ±5 % |
Potentials: 24 V analog supply UANA (potential jumper)
Supply Voltage | 24 V DC -15 % / +20 % |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Potentials: 24 V main supply UM
Supply Voltage | 24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Potentials: 24 V segment supply US
Supply Voltage | 24 V DC -15 % / +20 % (in accordance with EN 61131) |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Supply: Module electronics
Current consumption | 20 mA |
Connection technology
Connection name | Inline connector |
Conductor connection
Connection Method | Spring-cage connection |
Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm |
Inline connector
Connection Method | Spring-cage connection |
Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
Stripping length | 8 mm |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 55 °C |
Degree of Protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 10 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
UL, USA/Canada
Identification | cULus |
Certificate | E238705 |
Mounting
Mounting Type | DIN rail mounting |
Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 1020304?
Proax is an authorized distributor of Phoenix Contact 1020304 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended