Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2906786
Weight
0.058 kg
This product is Not Cancellable/Not Returnable
Series TTC

TTC-6P-3-HF-F-M-12DC-UT-I - Surge protection device

Surge protection, consisting of protective plug and base element, with integrated status indicator and knife disconnection for three signal wires with common reference potential. For HF applications and telecommunications interfaces without supply voltage. Indirect grounding via gas discharge tube, EX e approval for zone 2. Can be used in safety-related circuits up to SIL 3.

  • Space-saving and cost-saving with a narrow overall width of just 6 mm
  • Continuous monitoring of protective devices, plus mechanical status indicator with optional remote signaling
  • Finding the right product for all possible requirements in MCR applications is easy, thanks to the complete range of products with customized features
  • Easy testing and documentation with CHECKMASTER 2 with pluggable protective modules
  • The signal is not influenced during maintenance work, thanks to the impedance-neutral insertion and removal of protective plugs
Technical Specifications

Product properties

Product familyTERMITRAB complete
IEC test classificationC1
IEC test classificationC2
IEC test classificationC3
IEC test classificationD1
TypeDIN rail module, two-section, divisible

Insulation characteristics

Overvoltage categoryIII
Pollution degree2

Electrical properties

Nominal voltage UN12 V DC

Connection data

Connection MethodScrew connection
Screw threadM3
Tightening torque0.5 Nm ... 0.6 Nm
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section rigid0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 12

Ex data

Maximum input current600 mA (T4 / ≤ 30 °C)
Maximum input current500 mA (T4 / > 30 °C ... ≤ 50 °C)
Maximum input current400 mA (T4 / > 50 °C ... ≤ 70 °C)
Maximum input voltage15 V DC
Altitude≤ 2000 m (amsl)
Ambient Temperature (Operation)-40 °C ... 70 °C (T4)

Dimensions

Width6.2 mm +0.1 mm
Height105.8 mm
Depth100 mm (incl. DIN rail 7.5 mm)

Material specifications

Color (Base element)gray (RAL 7042)
Color (Male connector)light grey (RAL 7035)
Flammability rating according to UL 94V-0
Insulating materialPBT
Housing MaterialPBT

Mechanical data

Open side panelNo

Protective circuit

Direction of actionLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Maximum continuous voltage UC15 V DC
Maximum continuous voltage UC10 V AC
Rated current600 mA (56 °C)
Operating effective current IC at UC≤ 100 µA
Residual current IPE≤ 1 µA
Nominal discharge current In (8/20) µs (line-line)5 kA
Nominal discharge current In (8/20) µs (line-ground)5 kA
Nominal discharge current In (8/20) µs (line-signal ground)5 kA
Pulse discharge current Iimp (10/350) µs (line-line)0.5 kA
Pulse discharge current Iimp (10/350) µs (line-earth)0.5 kA
Pulse discharge current Iimp (10/350) µs (line-signalground)0.5 kA
Total discharge current Itotal (8/20) µs10 kA
Voltage protection level Up (line-line)≤ 145 V (C1 - 1 kV / 500 A)
Voltage protection level Up (line-line)≤ 260 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-line)≤ 25 V (C3 - 25 A)
Voltage protection level Up (line-line)≤ 30 V (C3 - 100 A)
Voltage protection level Up (line-earth)≤ 750 V (C1 - 1 kV / 500 A)
Voltage protection level Up (line-earth)≤ 750 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-earth)≤ 1.1 kV (C3 - 25 A)
Voltage protection level Up (line-earth)≤ 1.2 kV (C3 - 100 A)
Voltage protection level Up (line-signalground)≤ 80 V (C1 - 1 kV / 500 A)
Voltage protection level Up (line-signalground)≤ 95 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-signalground)≤ 25 V (C3 - 25 A)
Voltage protection level Up (line-signalground)≤ 30 V (C3 - 100 A)
Voltage protection level Up static (line-line)≤ 40 V (C1 - 1 kV / 500 A)
Voltage protection level Up static (line-line)≤ 95 V (C2 - 10 kV / 5 kA)
Voltage protection level Up static (line-earth)≤ 750 V (C1 - 1 kV / 500 A)
Voltage protection level Up static (line-earth)≤ 750 V (C2 - 10 kV / 5 kA)
Voltage protection level Up static (line-signalground)≤ 40 V (C1 - 1 kV / 500 A)
Voltage protection level Up static (line-signalground)≤ 95 V (C2 - 10 kV / 5 kA)
Response time tA (line-line)≤ 1 ns
Response time tA (line-earth)≤ 100 ns
Response time tA (line-signalground)≤ 1 ns
Input attenuation aE, sym.typ. 0.3 dB (≤ 8.7 MHz / 150 Ω)
Input attenuation aE, asym.typ. 0.3 dB (≤ 10.5 MHz / 150 Ω)
Cut-off frequency fg (3 dB), sym. in 150 Ω systemtyp. 60 MHz
Cut-off frequency fg (3 dB), asym. (signal ground) in 150 Ω systemtyp. 60 MHz
Capacity (core-core)typ. 32 pF
Capacity (line-signalground)typ. 32 pF
Resistance per path1.65 Ω ±20 %
Surge protection fault messageoptical
Max. required back-up fuse630 mA (FF)
Impulse durability (line-line)C1 - 1 kV / 500 A
Impulse durability (line-line)C2 - 10 kV / 5 kA
Impulse durability (line-line)C3 - 100 A
Impulse durability (line-earth)C1 - 1 kV / 500 A
Impulse durability (line-earth)C2 - 10 kV / 5 kA
Impulse durability (line-earth)C3 - 100 A
Impulse durability (line-earth)D1 - 500 A
Impulse durability (line-signalground)C1 - 1 kV / 500 A
Impulse durability (line-signalground)C2 - 10 kV / 5 kA
Impulse durability (line-signalground)C3 - 100 A
Impulse durability (line-signalground)D1 - 500 A
Pulse reset time (line-line)≤ 30 ms
Pulse reset time (line-earth)≤ 30 ms
Pulse reset time (line-signalground)≤ 30 ms

Additional technical data

Max. total discharge current I total max (8/20) µs20 kA (1x - non Ex)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 85 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 4000 m (amsl)
Permissible humidity (operation)5 % ... 95 %

Standards and Regulations

Standards/specificationsIEC 61643-21
Note2000 + corrigendum 2001 + A1:2008, modified + A2:2012

EN 61643-21

Standards/specificationsEN 61643-21
Note2001 + A1:2009 + A2:2013
Standards/specificationsIEC 60079-0
Note2017
Standards/specificationsIEC 60079-7
Note2017
Standards/specificationsEN IEC 60079-0
Note2018
Standards/specificationsEN IEC 60079-7
Note2015 + A1:2018

Mounting

Mounting TypeDIN rail: TH 35 - 7.5 mm
Accessories

Why Proax for Phoenix Contact TTC-6P-3-HF-F-M-12DC-UT-I?

Proax is an authorized distributor of Phoenix Contact TTC-6P-3-HF-F-M-12DC-UT-I and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesTTC6P3HFFM12DCUTI
Pack Size1
Recommended

Available for order