TTC-6P-3-HF-F-M-EX-24DC-UT-I - Surge protection device

Surge protection with integrated status indicator and knife disconnection for a 3-wire Ex i signal circuit with common reference potential. For HF applications. Indirect grounding via gas discharge tube, HART-compatible. Suitable for use in the fieldbus system (e.g., PROFIBUS PA) in accordance with the FISCO concept, APL ready. Can be used in safety-related circuits up to SIL 3.

  • Space-saving and cost-saving with a narrow overall width of just 6 mm
  • Continuous monitoring of protective devices, plus mechanical status indicator with optional remote signaling
  • Finding the right product for all possible requirements in MCR applications is easy, thanks to the complete range of products with customized features
  • Easy testing and documentation with CHECKMASTER 2 with pluggable protective modules
  • The signal is not influenced during maintenance work, thanks to the impedance-neutral insertion and removal of protective plugs
Technical Specifications

Product properties

Product familyTERMITRAB complete
IEC test classificationC1
IEC test classificationC2
IEC test classificationC3
IEC test classificationD1
TypeDIN rail module, two-section, divisible

Insulation characteristics

Overvoltage categoryIII
Pollution degree2

Electrical properties

Nominal voltage UN24 V DC

Connection data

Connection MethodScrew connection
Screw threadM3
Tightening torque0.5 Nm ... 0.6 Nm
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section rigid0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 12

Ex data

Maximum inner capacitance Cinegligible
Max. internal inductance Linegligible
Max. input current Ii400 mA (T4 / -40 °C ... +50 °C)
Max. input current Ii250 mA (T4 / -40 °C ... +70 °C)
Max. input current Ii350 mA (T6 / -40 °C ... +35 °C)
Max. input current Ii100 mA (T6 / -40 °C ... +70 °C)
Max. input current Ii400 mA (CCC: Ex ic [ia Ga] IIC T4 Gc / -40 °C ... +70 °C)
Max. input voltage Ui30 V DC
Insulation voltage to ground> 180 V DC
Ambient Temperature (Operation)-40 °C ... 70 °C (with current derating)

Dimensions

Width6.2 mm +0.1 mm
Height105.8 mm
Depth100 mm (incl. DIN rail 7.5 mm)

Material specifications

Colorblue (RAL 5015)
Flammability rating according to UL 94V-0
Insulating materialPBT
Housing MaterialPBT

Mechanical data

Open side panelNo

Protective circuit

Direction of actionLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Maximum continuous voltage UC30 V DC
Rated current600 mA (40 °C)
Operating effective current IC at UC≤ 5 µA
Residual current IPE≤ 1 µA
Nominal discharge current In (8/20) µs (line-line)5 kA
Nominal discharge current In (8/20) µs (line-ground)5 kA
Nominal discharge current In (8/20) µs (line-signal ground)5 kA
Pulse discharge current Iimp (10/350) µs (line-line)0.5 kA
Pulse discharge current Iimp (10/350) µs (line-earth)0.5 kA
Pulse discharge current Iimp (10/350) µs (line-signalground)0.5 kA
Total discharge current Itotal (8/20) µs10 kA
Voltage protection level Up (line-line)≤ 150 V (C1 - 1 kV / 500 A)
Voltage protection level Up (line-line)≤ 275 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-line)≤ 55 V (C3 - 100 A)
Voltage protection level Up (line-earth)≤ 750 V (C1 - 1 kV / 500 A)
Voltage protection level Up (line-earth)≤ 750 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-earth)≤ 1.2 kV (C3 - 100 A)
Voltage protection level Up (line-signalground)≤ 80 V (C1 - 1 kV / 500 A)
Voltage protection level Up (line-signalground)≤ 125 V (C2 - 10 kV / 5 kA)
Voltage protection level Up (line-signalground)≤ 55 V (C3 - 100 A)
Voltage protection level Up static (line-line)≤ 75 V (C1 - 1 kV / 500 A)
Voltage protection level Up static (line-line)≤ 120 V (C2 - 10 kV / 5 kA)
Voltage protection level Up static (line-earth)≤ 750 V (C1 - 1 kV / 500 A)
Voltage protection level Up static (line-earth)≤ 750 V (C2 - 10 kV / 5 kA)
Voltage protection level Up static (line-signalground)≤ 75 V (C1 - 1 kV / 500 A)
Voltage protection level Up static (line-signalground)≤ 120 V (C2 - 10 kV / 5 kA)
Response time tA (line-line)≤ 1 ns
Response time tA (line-earth)≤ 100 ns
Response time tA (line-signalground)≤ 1 ns
Input attenuation aE, sym.typ. 0.3 dB (≤ 8.7 MHz / 150 Ω)
Input attenuation aE, asym.typ. 0.3 dB (≤ 10.5 MHz / 150 Ω)
Cut-off frequency fg (3 dB), sym. in 150 Ω systemtyp. 60 MHz
Cut-off frequency fg (3 dB), asym. (signal ground) in 150 Ω systemtyp. 60 MHz
Capacity (core-core)typ. 32 pF
Capacity (line-signalground)typ. 32 pF
Resistance per path1.65 Ω ±20 %
Surge protection fault messageoptical
Max. required back-up fuse630 mA (FF)
Impulse durability (line-line)C1 - 1 kV / 500 A
Impulse durability (line-line)C2 - 10 kV / 5 kA
Impulse durability (line-line)C3 - 100 A
Impulse durability (line-earth)C1 - 1 kV / 500 A
Impulse durability (line-earth)C2 - 10 kV / 5 kA
Impulse durability (line-earth)C3 - 100 A
Impulse durability (line-earth)D1 - 500 A
Impulse durability (line-signalground)C1 - 1 kV / 500 A
Impulse durability (line-signalground)C2 - 10 kV / 5 kA
Impulse durability (line-signalground)C3 - 100 A
Impulse durability (line-signalground)D1 - 500 A
Pulse reset time (line-line)≤ 600 ms
Pulse reset time (line-earth)≤ 30 ms
Pulse reset time (line-signalground)≤ 600 ms

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 85 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m (amsl)
Permissible humidity (operation)5 % ... 95 %

Conformity/Approvals

UL, USA / CanadaClass I, Div. 2, Groups A, B, C, D T4A

Standards and Regulations

Standards/specificationsEN 60079-0
Note2018
Standards/specificationsEN 60079-11
Note2012

EN 61643-21

Standards/specificationsEN 61643-21
Note2001 + A1:2009 + A2:2013
Standards/specificationsIEC 60079-0
Note2017
Standards/specificationsIEC 60079-11
Note2008
Standards/specificationsIEC 61643-21
Note2000 + corrigendum 2001 + A1:2008, modified + A2:2012

Mounting

Mounting TypeDIN rail: TH 35 - 7.5 mm
Accessories

Why Proax for Phoenix Contact TTC-6P-3-HF-F-M-EX-24DC-UT-I?

Proax is an authorized distributor of Phoenix Contact TTC-6P-3-HF-F-M-EX-24DC-UT-I and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesTTC6P3HFFMEX24DCUTI
Pack Size1
Recommended

Available for order