proax logo
fr0 Items
proax logo
Cart

1424656

By Phoenix Contact

PHX1424656
Phoenix ContactOfficial Distributor

SACC-M12FR-4PL M - Connector

Connector, Universal, 4-position, unshielded, Socket angled M12, coding: A, Push-lock spring connection, knurl material: Zinc die-cast, nickel-plated, external cable diameter 4 mm ... 8 mm

  • Time-saving Push-Lock connection: Tool-free connection and disconnection of conductors by opening the contact levers
  • Intuitive connection: Easy assignment of individual litz wires with color-coded and numerical identification of the contact levers
  • Integrated Push-in Technology: Wire rigid and pretreated conductors easily by means of simple, direct insertion
  • Shock- and vibration-resistant connection: Proven spring-cage technology guarantees secure and reliable contacting
  • Flexible cable outlets with angled connectors
Technical Specifications

Notes

Assembly instruction:NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties.

Mounting

Assembly instructionsThe connector pin assignment can be rotated 45° to the cable outlet
Assembly instructionsThe wires can be connected both with ferrules and without ferrules

Product properties

Sensor TypeUniversal
Number of Positions4
No. of cable outlets1
Shieldedno
CodingA
Cable outletangled

Insulation characteristics

Overvoltage categoryII
Degree of pollution3

Dimensions

Length49 mm

External dimensions

Outside diameter4 mm ... 8 mm

Housing

Diameter housing19 mm

Material specifications

MaterialPBT
MaterialPA 6
Flammability rating according to UL 94V0
Seal materialNBR
Material of grip bodyPA 6.6
Contact MaterialCuSn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionZinc die-cast, nickel-plated
Standards/regulationsPA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, R24, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Standards/regulationsPA 6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Standards/regulationsPBT: Fire protection in rail vehicles - requirement sets R22, R23, R24, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL2, R26: HL3)

Conductor connection

Connection MethodPush-lock spring connection
Connection cross section0.14 mm² ... 0.75 mm² (without ferrule)
Connection cross section0.08 mm² ... 0.5 mm² (with ferrule)
Connection cross section0.14 mm² ... 0.75 mm² (solid)
Connection cross section AWG26 ... 18 (without ferrule)
Connection cross section AWG28 ... 20 (with ferrule)
Stripping length of the individual wire7 mm
Tightening torque0.4 Nm (M12 knurl)
Tightening torque0.4 Nm (Connector with coupling sleeve)
Tightening torque1.5 Nm (Pressure nut with coupling sleeve)

Pin assignment

Contact | Color (signal designation) | Contact (optional)1 = BN
Contact | Color (signal designation) | Contact (optional)2 = WH
Contact | Color (signal designation) | Contact (optional)3 = BU
Contact | Color (signal designation) | Contact (optional)4 = BK

Electrical properties

Rated surge voltage2.5 kV
Contact resistance≤ 5 mΩ
Insulation resistance≥ 100 MΩ
Nominal voltage UN250 V AC
Nominal voltage UN250 V DC
Nominal current IN4 A (2 A when using 0.14 mm² conductors)

Mechanical data

Insertion/withdrawal cycles≥ 100 (Quantity: 500 with Phoenix Contact mating connector)

Connection 1

Head designSocket
Head cable outletangled
Head thread typeM12
CodingA

Cable/line

Signal type/categoryUniversal
Stripping length of the individual wire7 mm

Ambient conditions

Degree of ProtectionIP65
Degree of ProtectionIP67
Ambient Temperature (Operation)-40 °C ... 85 °C (Plug / socket)

Testing

Standards/regulationsPA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, R24, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Standards/regulationsPA 6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Standards/regulationsPBT: Fire protection in rail vehicles - requirement sets R22, R23, R24, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL2, R26: HL3)

M12

Standard designationM12 connector
Standards/specificationsIEC 61076-2-101
Standard designationShock, vibration
Standards/specificationsEN 50155:2001
Accessories

Why Proax for Phoenix Contact 1424656?

Proax is an authorized distributor of Phoenix Contact 1424656 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Best Sellersin Circular connectors

Available for order