Series QUINT4-UPS
QUINT4-UPS/1AC/1AC/1KVA - Uninterruptible power supply
Uninterruptible power supply with IQ technology for DIN rail mounting. Input: 120/230 V AC, output: 120/230 V AC/1 kVA. Provides information regarding the state of charge, remaining runtime, and service life of the rechargeable battery module at any time, thereby increasing system availability.
- Smooth transition due to online topology
- Pure sine curve in mains and battery operation
- USB interface for connecting to industrial PCs, for example
- Startup from energy storage possible, even without mains input
- Can be switched in parallel for redundancy and increased performance
Technical Specifications
AC operation
| Input Voltage | 100 V AC -10 % / +20 % | 
| Input Voltage | 110 V AC -10 % / +20 % | 
| Input Voltage | 120 V AC -10 % / +20 % | 
| Input Voltage | 130 V AC -10 % / +20 % | 
| Input Voltage | 200 V AC -20 % / +20 % | 
| Input Voltage | 210 V AC -20 % / +20 % | 
| Input Voltage | 220 V AC -20 % / +20 % | 
| Input Voltage | 230 V AC -20 % / +15 % | 
| Input Voltage | 240 V AC -20 % / +10 % | 
| Input voltage range | 90 V AC ... 264 V AC | 
| Input Voltage Range AC | 184 V AC ... 264 V AC | 
| Input Voltage Range AC | 96 V AC ... 144 V AC | 
| Typical national grid voltage | 120 V AC | 
| Typical national grid voltage | 230 V AC | 
| Voltage type of supply voltage | AC | 
| AC frequency range | 45 Hz ... 65 Hz | 
| Buffer period | 1 h (38 AH) | 
| Current consumption | 10.4 A (100 V AC) | 
| Current consumption | 10.5 A (110 V AC) | 
| Current consumption | 10.5 A (120 V AC) | 
| Current consumption | 9.7 A (130 V AC) | 
| Current consumption | 6.4 A (200 V AC) | 
| Current consumption | 6 A (210 V AC) | 
| Current consumption | 5.7 A (220 V AC) | 
| Current consumption | 5.5 A (230 V AC) | 
| Current consumption | 5.3 A (240 V AC) | 
| Variable connect threshold | Can be configured using UPS-CONF software | 
| Power factor (cos phi) | 0.9 | 
| Bypass fuse | T 15 A / 250 V (MDA -15-R) | 
| Permissible backup fuse | B16 230 V AC | 
| Permissible backup fuse | 20 A (120 V AC, Listed breaker) | 
Digital Control (configurable)
| Designation | Remote | 
| Low signal | Connection to SGnd with < 2.7 kΩ | 
| High signal | Open (> 35 kΩ between Remote and SGnd) | 
Digital Control Low-Active (configurable)
| Battery-operated start 120 V AC low signal | Connection to SGnd with < 2.7 kΩ | 
| Battery-operated start 120 V AC high signal | Open (> 200 kΩ between Bat.-Start and SGnd) | 
Output data
| Classification according to IEC 62040-3 | VFI-SS-111 | 
| Efficiency | > 92 % (120 V AC) | 
| Efficiency | > 94 % (230 V AC) | 
| Nominal Output Voltage | 100 V AC | 
| Nominal Output Voltage | 110 V AC | 
| Nominal Output Voltage | 120 V AC | 
| Nominal Output Voltage | 130 V AC | 
| Nominal Output Voltage | 200 V AC | 
| Nominal Output Voltage | 210 V AC | 
| Nominal Output Voltage | 220 V AC | 
| Nominal Output Voltage | 230 V AC | 
| Nominal Output Voltage | 240 V AC | 
| Form of output voltage | Pure sine | 
| Nominal output current (IN) | 7.8 A (100 V AC) | 
| Nominal output current (IN) | 8.1 A (110 V AC) | 
| Nominal output current (IN) | 8.3 A (120 V AC) | 
| Nominal output current (IN) | 7.7 A (130 V AC) | 
| Nominal output current (IN) | 5 A (200 V AC) | 
| Nominal output current (IN) | 4.8 A (210 V AC) | 
| Nominal output current (IN) | 4.5 A (220 V AC) | 
| Nominal output current (IN) | 4.3 A (230 V AC) | 
| Nominal output current (IN) | 4.2 A (240 V AC) | 
| POWER BOOST (IBoost) | 13 A (120 V AC) | 
| POWER BOOST (IBoost) | 7 A (230 V AC) | 
| Output Power | 778 VA (700 W) | 
| Output Power | 889 VA (800 W) | 
| Output Power | 1000 VA (900 W) | 
| Output Power | 1000 VA (900 W) | 
| Output Power | 1000 VA (900 W) | 
| Output Power | 1000 VA (900 W) | 
| Output Power | 1000 VA (900 W) | 
| Output Power | 1000 VA (900 W) | 
| Output Power | 1000 VA (900 W) | 
| Apparent power | 1 kVA (UN  120 V AC) | 
| Nominal power | 900 W (UN  120 V AC) | 
| Maximum no-load power dissipation | typ. 17 W (120 V AC) | 
| Maximum no-load power dissipation | typ. 25 W (230 V AC) | 
| Power loss nominal load max. | typ. 79 W (120 V AC) | 
| Power loss nominal load max. | typ. 55 W (230 V AC) | 
| Crest factor | 2.8 | 
| Switch-over time | 0 ms | 
| Connection in parallel | yes, 2 | 
| Connection in series | No | 
Mains operation
| Nominal Output Voltage | 120 V AC ±2 % | 
| Nominal Output Voltage | 230 V AC ±2 % | 
| Nominal output current (IN) | 8.3 A | 
| Nominal output current (IN) | 4.3 A (230 V AC) | 
| POWER BOOST (IBoost) | 13 A | 
| POWER BOOST (IBoost) | 7 A | 
Battery operation
| Nominal Output Voltage | 120 V AC ±2 % | 
| Nominal Output Voltage | 230 V AC ±2 % | 
| Nominal output current (IN) | 4.3 A (230 V AC) | 
| Nominal output current (IN) | 8.3 A (120 V AC) | 
| POWER BOOST (IBoost) | 7 A (230 V AC) | 
| POWER BOOST (IBoost) | 13 A (120 V AC) | 
| Nominal output frequency | ± 60 Hz ±0.5 % (At an input frequency of 55 Hz to < 65 Hz) | 
| Nominal output frequency | ± 50 Hz ±0.5 % (At an input frequency of 45 Hz to < 55 Hz) | 
Signal: AC OK
| Output Voltage | 24 V | 
| Continuous load current | ≤ 20 mA | 
Signal: Alarm
| Output Voltage | 24 V | 
| Continuous load current | ≤ 20 mA | 
Signal: Battery mode
| Output Voltage | 24 V | 
| Continuous load current | ≤ 20 mA | 
Signal: Ready
| Output Voltage | 24 V | 
| Continuous load current | ≤ 20 mA | 
Signal: P>Pn
| Output Voltage | 24 V (SELV) | 
| Continuous load current | ≤ 20 mA | 
Energy storage
| Nominal voltage UN | 2x 24 V DC | 
| End-of-charge voltage | 58 V (temperature compensated) | 
| Charging current | 5 A | 
| Nominal capacity range | 3.4 Ah ... 190 Ah (5x 38 Ah) | 
| Battery technology | VRLA, VRLA-WTR | 
| Charge characteristic curve | IU0U | 
| Permissible backup fuse | 50 A /  58 V | 
Input
| Connection Method | Screw connection | 
| Conductor cross section, rigid min. | 0.2 mm² | 
| Conductor cross section, rigid max. | 6 mm² | 
| Conductor cross section flexible min. | 0.2 mm² | 
| Conductor cross section flexible max. | 4 mm² | 
| Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 0.25 mm² | 
| Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 4 mm² | 
| Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.25 mm² | 
| Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 4 mm² | 
| Conductor cross section AWG min. | 30 | 
| Conductor cross section AWG max. | 10 | 
| Stripping length | 8 mm | 
| Tightening torque, min | 0.5 Nm | 
| Tightening torque max | 0.6 Nm | 
Output
| Connection Method | Screw connection | 
| Conductor cross section, rigid min. | 0.2 mm² | 
| Conductor cross section, rigid max. | 6 mm² | 
| Conductor cross section flexible min. | 0.2 mm² | 
| Conductor cross section flexible max. | 4 mm² | 
| Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 0.25 mm² | 
| Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 4 mm² | 
| Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.25 mm² | 
| Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 4 mm² | 
| Conductor cross section AWG min. | 30 | 
| Conductor cross section AWG max. | 10 | 
| Stripping length | 8 mm | 
| Tightening torque, min | 0.5 Nm | 
| Tightening torque max | 0.6 Nm | 
Signal
| Connection Method | Screw connection | 
| Conductor cross section, rigid min. | 0.2 mm² | 
| Conductor cross section, rigid max. | 2.5 mm² | 
| Conductor cross section flexible min. | 0.2 mm² | 
| Conductor cross section flexible max. | 2.5 mm² | 
| Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 0.2 mm² | 
| Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 2.5 mm² | 
| Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.2 mm² | 
| Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 2.5 mm² | 
| Conductor cross section AWG min. | 30 | 
| Conductor cross section AWG max. | 12 | 
| Stripping length | 8 mm | 
| Tightening torque, min | 0.5 Nm | 
| Tightening torque max | 0.6 Nm | 
Interfaces
| Interface | MINI-USB type B | 
| Features | lockable | 
| Maximum cable length | 3 m | 
Signaling
| Types of signaling | LED | 
| Types of signaling | Active switching output | 
Signal output: Transistor output, active
| Signalization designation | AC OK | 
| Status display | LED | 
| Color | green | 
| Signalization designation | Alarm | 
| Status display | LED | 
| Color | red | 
| Signalization designation | Battery mode | 
| Status display | LED | 
| Color | yellow | 
| Signalization designation | Ready | 
| Signalization designation | P>Pn | 
| Status display | LED | 
| Color | green | 
Signal output
| Signalization designation | Reference potential for the signal inputs and outputs | 
Electrical properties
| Number of phases | 1.00 | 
Product properties
| Product family | QUINT AC-USV | 
| MTBF (IEC 61709, SN 29500) | 217546 h (230 V AC, at 40 °C) | 
Insulation characteristics
| Protection class | I | 
| Overvoltage category | II | 
| Pollution degree | 3 (≤ 130 V AC) | 
| Pollution degree | 2 (> 200 V AC) | 
Life expectancy (electrolytic capacitors)
| Time | 68970 h | 
Dimensions
| Width | 290 mm | 
| Height | 130 mm | 
| Depth | 125 mm | 
Installation dimensions
| Installation distance right/left | 5 mm / 5 mm | 
| Installation distance top/bottom | 50 mm / 50 mm | 
Mounting
| Mounting Type | DIN rail mounting | 
Material specifications
| Housing Material | Metal | 
| Hood version | Sheet steel, DIN EN ISO2081 coat - Fe/Zn 18/B/TopCoat transparent blue | 
| Side element version | Aluminum plate, DIN EN 573-3 | 
Ambient conditions
| Degree of Protection | IP20 | 
| Ambient Temperature (Operation) | -25 °C ... 60 °C (> 50 °C: 2,5 % / K) | 
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | 
| Maximum altitude | ≤ 3000 m (> 2000 m: 0,6 % / 100 m) | 
| Climatic class | 3K3 (EN 60721) | 
| Max. permissible relative humidity (operation) | ≤ 95 % | 
| Shock | 15g in all directions (EN 60068-2-27) | 
| Vibration (Operation) | 5 Hz ... 100 Hz, 0.7g (EN 60068-2-6) | 
Uninterruptible power supply systems
| Standard designation | Uninterruptible power supply systems | 
| Standards/specifications | EN 62040-1 | 
UL
| Identification | UL/C-UL Recognized UL 1778 | 
EMC data
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC | 
| Interference emission | Noise emission in accordance with EN 62040-2 | 
| Noise immunity | Immunity in accordance with EN 62040-2 | 
| Noise immunity | Immunity in accordance with EN 61000-6-1 (residential), EN 61000-6-2 (industrial) | 
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | 
| Conducted noise emission | EN 62040-02 (Class C2) | 
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 | 
| Contact discharge | ± 6 kV | 
| Discharge in air | ± 8 kV | 
| Comments | Criterion A | 
Electromagnetic HF field
| Standards/regulations | EN 61000-4-3 | 
| Frequency Range | 80 MHz ... 6 GHz | 
| Test field strength | 10 V/m | 
| Comments | Criterion A | 
Fast transients (burst)
| Standards/regulations | EN 61000-4-4 | 
| Input | ± 2 kV | 
| Input | ± 2 kV | 
| Output | ± 2 kV | 
| Signal | ± 2 kV | 
| Signal | ± 2 kV (USB) | 
| Comments | Criterion A (B for USB) | 
Surge voltage load (surge)
| Standards/regulations | EN 61000-4-5 | 
| Signal | 1 kV (asymmetrical) | 
| Comments | Criterion B | 
| Input/Output | ± 1 kV (symmetrical) | 
| Input/Output | ± 2 kV (asymmetrical) | 
Conducted interference
| Standards/regulations | EN 61000-4-6 | 
| Frequency Range | 0.15 MHz ... 80 MHz | 
| Comments | Criterion A | 
| Voltage | 10 V | 
Power frequency magnetic field
| Standards/regulations | EN 61000-4-8 | 
| Frequency | 50 Hz | 
| Frequency | 60 Hz | 
| Test field strength | 100 A/m | 
| Comments | Criterion A | 
Criteria
| Criterion A | Normal operating behavior within the specified limits. | 
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. | 
Accessories
Why Proax for Phoenix Contact 2320283?
Proax is an authorized distributor of Phoenix Contact 2320283 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 | 
Recommended