By ABB
SKU
MPN
GJL1313003R0105
Weight
1 kg
The BC7-30-10-F mini contactor is a compact 3 pole contactor with 1 auxiliary contact and flat pin connection. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A (AC-1) or switching of control signals. Further features are the noiseless and hum-free coil, a switch position indication and the integrated possibility for rail or wall mounting.
Technical Specifications
Dimensions
Product Net Width | 52.5 mm |
Product Net Height | 57.5 mm |
Product Net Depth / Length | 46.7 mm |
Product Net Weight | 0.17 kg |
Technical
Number of Poles | 3 |
Mini Contactor Type | Mini Contactor |
Rated Operational Voltage | Auxiliary Circuit 690 V AC |
Rated Operational Voltage | Auxiliary Circuit 250 V DC |
Rated Operational Voltage | Main Circuit 690 V AC |
Rated Operational Voltage | Main Circuit 220 V DC |
Rated Frequency (f) | Control Circuit DC |
Rated Frequency (f) | Main Circuit 50 Hz |
Rated Frequency (f) | Main Circuit 60 Hz |
Rated Frequency (f) | Main Circuit DC |
Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kV |
Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
Rated Insulation Voltage (Ui) | 690 V |
Rated Insulation Voltage (Ui) | acc. to UL/CSA 600 V |
Number of Main Contacts NC | 0 |
Number of Main Contacts NO | 3 |
Rated Operational Current AC-1 (Ie) | (220 / 240 V) 40 °C 20 A |
Rated Operational Current AC-1 (Ie) | (220 / 240 V) 55 °C 16 A |
Rated Operational Current AC-1 (Ie) | (380 / 440 V) 40 °C 20 A |
Rated Operational Current AC-1 (Ie) | (380 / 440 V) 55 °C 16 A |
Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 6 A |
Rated Operational Current AC-1 (Ie) | (690 V) 55 °C 6 A |
Rated Operational Power AC-3 (Pe) | (230 V) Three Phase 3 kW |
Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 5.5 kW |
Rated Operational Power AC-3 (Pe) | (500 V) Three Phase 5.5 kW |
Rated Operational Power AC-3 (Pe) | (690 V) Three Phase, NO 3 kW |
Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A |
Number of Auxiliary Contacts NC | 0 |
Number of Auxiliary Contacts NO | 1 |
Rated Operational Current AC-15 (Ie) | (24 V) 4 A |
Rated Operational Current AC-15 (Ie) | (120 V) 4 A |
Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
Rated Operational Current AC-15 (Ie) | (220 / 240 V) 4 A |
Rated Operational Current AC-15 (Ie) | (380 / 400 V) 3 A |
Rated Operational Current DC-13 (Ie) | (24 V) 2.5 A |
Rated Operational Current DC-13 (Ie) | (110 V) 0.7 A |
Rated Operational Current DC-13 (Ie) | (220 / 240 V) 0.4 A |
Conventional Free-air Thermal Current (Ith) | Main Circuit 20 A |
Rated Control Circuit Voltage (Uc) | 220 ... 240 V DC |
Coil Operating Limits | (acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
Degree of Protection | Auxiliary Circuit Terminals IP20 |
Degree of Protection | Control Circuit Terminals IP20 |
Degree of Protection | Main Circuit Terminals IP20 |
Mechanical Durability | 10000000 cycle |
Minimum switching capacity | Auxiliary Circuit 17 V |
Minimum switching capacity | Auxiliary Circuit 5 mA |
Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
Maximum Electrical Switching Frequency | (AC-15) 600 cycles per hour |
Maximum Electrical Switching Frequency | (AC-3) 600 cycles per hour |
Maximum Electrical Switching Frequency | (DC-1) 600 cycles per hour |
Maximum Electrical Switching Frequency | (DC-13) 600 cycles per hour |
Maximum Electrical Switching Frequency | (DC-3) 600 cycles per hour |
Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Power Loss | at Rated Operating Conditions AC-1 per Pole 1.4 W |
Standards | IEC/EN 60947-1 |
Standards | IEC/EN 60947-4-1 |
Standards | IEC/EN 60947-5-1 |
Standards | UL 60947-1 |
Standards | UL 60947-4-1 |
Technical UL/CSA
Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
Full Load Amps Motor Use | (115 V AC) Single Phase 13.8 A |
Full Load Amps Motor Use | (200 V AC) Three Phase 7.8 A |
Full Load Amps Motor Use | (220 ... 240 V AC) Three Phase 9.6 A |
Full Load Amps Motor Use | (230 V AC) Single Phase 10 A |
Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 7.6 A |
Full Load Amps Motor Use | (550 ... 600 V AC) Three Phase 6.1 A |
Horsepower Rating UL/CSA | (115 V AC) Single Phase 0.75 Hp |
Horsepower Rating UL/CSA | (200 V AC) Three Phase 2 Hp |
Horsepower Rating UL/CSA | (220 ... 240 V AC) Three Phase 3 Hp |
Horsepower Rating UL/CSA | (230 V AC) Single Phase 1.5 Hp |
Horsepower Rating UL/CSA | (440 ... 480 V AC) Three Phase 5 Hp |
Horsepower Rating UL/CSA | (550 ... 600 V AC) Three Phase 5 Hp |
General Use Rating UL/CSA | (600 V AC) 16 A |
Contact Rating UL/CSA | A600 |
Why Proax for ABB BC7-30-10-F-05?
Proax is an authorized distributor of ABB BC7-30-10-F-05 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | BC73010F05 |
Pack Size | 1 |
Recommended