Phoenix Contact Current and voltage measuring
MACX MCR-SL-CAC- 5-I - Current measuring transducer for 1 A and 5 A AC, the output signal 0...20 mA or 4...20 mA, can be configured using a DIP switch with an operating mode indication through an LED
Not in stock
MCR-SL-CUC-100-I - Universal current transducer, for measuring AC, DC, and distorted currents, 0 ... 100 A input current, 4 ... 20 mA output
Not in stock
MCR-SL-S-100-I-LP - MCR current measuring transducer, for measuring sinusoidal and non-sinusoidal alternating currents, input current 0...100 A, loop-powered output with 4...20 mA
Not in stock
MCR-S10-50-UI-SW-DCI-NC - MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, with relay and transistor output, input current 0...10 to 0...50 A, unconfigured
Not in stock
MCR-S10-50-UI-DCI-NC - MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, input current 0...10 to 0...50 A, unconfigured
Not in stock
MCR-SL-CUC-200-I - Universal current transducer, for measuring AC, DC, and distorted currents, 0 ... 200 A input current, 4 ... 20 mA output
Not in stock
PACT MCR-V2-3015- 60- 200-5A-1 - Window-type current transformer, 200 A AC primary current; 5 A AC secondary current; accuracy class 1; 5 VA rated power
Not in stock
MCR-S-1-5-UI-SW-DCI-NC - MCR current transducer, programmable and configurable, for measuring direct, alternating and distorted currents, with relay and transistor output, input current 0 ... 0.2 A to 0 ... 11 A, unconfigured
Not in stock
PACT MCR-V1-21-44- 50-5A-1 - Bus-bar current transformer, 50 A AC primary current; 5 A AC secondary current; accuracy class 1; 1.25 VA rated power
Not in stock
PACT MCR-V2-3015- 60- 100-5A-1 - Window-type current transformer, 100 A AC primary current; 5 A AC secondary current; accuracy class 1; 2.5 VA rated power
Not in stock
PACT MCR-V2-3015- 60- 60-5A-1 - Window-type current transformer, 60 A AC primary current; 5 A AC secondary current; accuracy class 1; 1.25 VA rated power
PACT MCR-V2-6015- 85-1000-5A-1 - Window-type current transformer, 1000 A AC primary current; 5 A AC secondary current; accuracy class 1; 15 VA rated power
Not in stock
MCR-SL-CUC-300-I - Universal current transducer, for measuring AC, DC, and distorted currents, 0 ... 300 A input current, 4 ... 20 mA output
Not in stock
MCR-SL-CUC-600-I - Universal current transducer, for measuring DC, AC, and distorted currents, 0 ... 600 A input current, 4 ... 20 mA output
Not in stock
MCR-SL-S- 16-SP- 24 - MCR current protector, for sinusoidal alternating currents 0 … 16 A AC/ 1 changeover contact
Not in stock
The optional holding device ensures the Rogowski coil is securely seated on busbars with a thickness of 10 ... 15 mm. During installation, the coil housing is pushed onto the flange of the holding device and snaps in automatically.
Not in stock