Official Distributor
SKU
MPN
DT-LAN-CAT.6A
Weight
0.319 kg
Series DT-LAN-CAT
DT-LAN-CAT.6A - Surge protection device
Surge protection in accordance with Class EA (CAT6A), for Gigabit Ethernet (up to 10 Gbps), token ring, FDDI/CDDI, ISDN, and DS1. Suitable for Power over Ethernet (PoE++ / 4PPoE) “Mode A” and “Mode B”. RJ45 attachment plug with separate grounding cable and ground connection snap-on foot for NS 35 DIN rails.
- Can be installed in a control cabinet by removing the ground connection adapter
- Suitable for category 6 high-speed data networks
Technical Specifications
Product properties
Product family | DATATRAB |
IEC test classification | B2 |
IEC test classification | C1 |
IEC test classification | C2 |
IEC test classification | C3 |
IEC test classification | D1 |
Type | Attachment plug for DIN rail mounting |
Number of Positions | 8 |
Surge protection fault message | none |
Wire pairs per module | 4 |
Insulation characteristics
Overvoltage category | II |
Pollution degree | 2 |
Connection data
Connection Method | RJ45 |
Dimensions
Width | 25 mm |
Height | 102 mm |
Depth | 63.5 mm |
Material specifications
Color | Silver |
Color | black (RAL 9005) |
Housing Material | Zinc die-cast |
Mechanical data
Open side panel | No |
Protective circuit
Direction of action | Line-Line & Line-Ground/Shield |
Maximum continuous voltage UC (line-line) | ≤ 3.3 V DC (±60 V DC/PoE+) |
Rated current | ≤ 1.5 A (25 °C) |
Operating effective current IC at UC | ≤ 1 µA |
Residual current IPE | ≤ 400 µA |
Nominal discharge current In (8/20) µs (line-line) | 100 A |
Nominal discharge current In (8/20) µs (line-ground) | 2 kA (per signal pair) |
Total discharge current Itotal (8/20) µs | 10 kA |
Nominal pulse current Ian (10/700) µs (line-line) | ≤ 40 A |
Nominal pulse current Ian (10/700) µs (line-earth) | ≤ 160 A |
Output voltage limitation at 1 kV/µs (line-line) spike | ≤ 85 V (PoE) |
Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 700 V |
Output voltage limitation at 1 kV/µs (line-line) static | ≤ 9 V |
Output voltage limitation at 1 kV/µs (line-earth) static | ≤ 700 V |
Residual voltage at In (conductor-conductor) | ≤ 15 V |
Residual voltage at In (conductor-conductor) | ≤ 100 V (PoE) |
Voltage protection level Up (line-line) | ≤ 9 V (B2 - 1 kV / 25 A) |
Voltage protection level Up (line-line) | ≤ 100 V (B2 - 1 kV / 25 A - PoE) |
Voltage protection level Up (line-earth) | ≤ 900 V (B2 - 4 kV / 100 A) |
Voltage protection level Up (line-earth) | ≤ 700 V (C2 - 4 kV / 2 kA) |
Response time tA (line-line) | ≤ 1 ns |
Response time tA (line-earth) | ≤ 100 ns |
Input attenuation aE, sym. | ≤ 1 dB (up to100 MHz/direct measuring) |
Input attenuation aE, sym. | ≤ 1 dB (up to 250 MHz/direct measuring) |
Input attenuation aE, sym. | ≤ 3 dB (up to 500 MHz/direct measuring) |
Near-end crosstalk attenuation | ≥ 35 dB (250 MHz/100 Ω/link) |
Near-end crosstalk attenuation | ≥ 45 dB (100 MHz / 100 Ω / Link) |
Near-end crosstalk attenuation | ≥ 27 dB (500 MHz / 100 Ω / Link) |
Near-end crosstalk attenuation | ≥ 39 dB (250 MHz/100 Ω/direct measuring) |
Capacity (core-core) | typ. 12 pF (f= 1 MHz / VR= 0 V) |
Capacity (core-earth) | typ. 2 pF (f= 1 MHz / VR= 0 V) |
Surge protection fault message | none |
Impulse durability (line-line) | B2 - 1 kV / 25 A |
Impulse durability (line-earth) | B2 - 4 kV / 100 A |
Impulse durability (line-earth) | C2 - 4 kV / 2 kA |
Impulse durability (line-earth) | D1 - 1 kA |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -40 °C ... 70 °C |
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Permissible humidity (operation) | 5 % ... 85 % |
Standards and Regulations
Standards/specifications | IEC 61643-21 |
Note | 2002 |
Standards/specifications | EN 50173-1 |
Note | 2002 |
Standards/specifications | ISO/IEC 11801-Am.1 |
Note | 2006 |
Mounting
Mounting Type | Connection-specific attachment plug and DIN rail, 35 mm |
Why Proax for Phoenix Contact 2908726?
Proax is an authorized distributor of Phoenix Contact 2908726 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- 2881007 - Surge protection in accordance with Class EA (CAT6A), for Gigabit Ethernet (up to 10 Gbps), token ring, FDDI/CDDI, ISDN, and DS1. Suitable for Power over Ethernet (PoE++ / 4PPoE) “Mode A” and “Mode B”. RJ45 attachment plug with separate grounding cable and ground connection snap-on foot for NS 35 DIN rails.