DT-LAN-CAT.6+ - Surge protection device

Surge protection in accordance with Class EA (CAT6A), for Gigabit Ethernet (up to 10 Gbps), token ring, FDDI/CDDI, ISDN, and DS1. Suitable for Power over Ethernet (PoE++ / 4PPoE) “Mode A” and “Mode B”. RJ45 attachment plug with separate grounding cable and ground connection snap-on foot for NS 35 DIN rails.

  • Can be used in applications up to 10 Gbps with adapted protective circuit
  • High power transmission with PoE++ / 4PPoE support
  • Easy network integration via RJ45 jacks
  • Can be installed in a control cabinet by removing the ground connection adapter
  • Suitable for category 6 high-speed data networks
Technical Specifications

Product properties

Product familyDATATRAB
IEC test classificationB2
IEC test classificationC1
IEC test classificationC2
IEC test classificationC3
IEC test classificationD1
TypeAttachment plug for DIN rail mounting
Number of Positions8
Wire pairs per module4

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Connection data

Connection MethodRJ45

Dimensions

Width25 mm
Height102 mm
Depth63.5 mm

Material specifications

ColorSilver
Colorblack (RAL 9005)
Housing MaterialZinc die-cast

Mechanical data

Open side panelNo

Protective circuit

Direction of actionLine-Line & Line-Ground/Shield
Maximum continuous voltage UC (line-line)≤ 3.3 V DC (±60 V DC / PoE)
Rated current≤ 1.5 A (25 °C)
Operating effective current IC at UC≤ 1 µA
Residual current IPE≤ 400 µA
Nominal discharge current In (8/20) µs (line-line)100 A
Nominal discharge current In (8/20) µs (line-ground)2 kA (per signal pair)
Pulse discharge current Iimp (10/350) µs (line-earth)1 kA
Total discharge current Itotal (8/20) µs10 kA
Nominal pulse current Ian (10/700) µs (line-line)≤ 40 A
Nominal pulse current Ian (10/700) µs (line-earth)≤ 160 A
Output voltage limitation at 1 kV/µs (line-line) spike≤ 85 V (PoE)
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 700 V
Output voltage limitation at 1 kV/µs (line-line) static≤ 9 V
Output voltage limitation at 1 kV/µs (line-earth) static≤ 700 V
Residual voltage at In (conductor-conductor)≤ 15 V
Residual voltage at In (conductor-conductor)≤ 100 V (PoE)
Voltage protection level Up (line-line)≤ 9 V (B2 - 1 kV / 25 A)
Voltage protection level Up (line-line)≤ 100 V (B2 - 1 kV / 25 A - PoE)
Voltage protection level Up (line-line)≤ 12 V (C3 - 20 A)
Voltage protection level Up (line-earth)≤ 900 V (B2 - 4 kV / 100 A)
Voltage protection level Up (line-earth)≤ 700 V (C2 - 4 kV / 2 kA)
Voltage protection level Up (line-earth)≤ 1 kV (C3 - 80 A)
Response time tA (line-line)≤ 1 ns
Response time tA (line-earth)≤ 100 ns
Input attenuation aE, sym.≤ 1 dB (up to100 MHz/direct measuring)
Input attenuation aE, sym.≤ 1 dB (up to 250 MHz/direct measuring)
Input attenuation aE, sym.≤ 3 dB (up to 500 MHz/direct measuring)
Near-end crosstalk attenuation≥ 35 dB (250 MHz/100 Ω/link)
Near-end crosstalk attenuation≥ 45 dB (100 MHz / 100 Ω / Link)
Near-end crosstalk attenuation≥ 27 dB (500 MHz / 100 Ω / Link)
Near-end crosstalk attenuation≥ 39 dB (250 MHz/100 Ω/direct measuring)
Capacity (core-core)typ. 12 pF (f= 1 MHz / VR= 0 V)
Capacity (core-earth)typ. 2 pF (f= 1 MHz / VR= 0 V)
Surge protection fault messagenone
Impulse durability (line-line)B2 - 1 kV / 25 A
Impulse durability (line-line)C3 - 20 A
Impulse durability (line-earth)B2 - 4 kV / 100 A
Impulse durability (line-earth)C2 - 4 kV / 2 kA
Impulse durability (line-earth)C3 - 80 A
Impulse durability (line-earth)D1 - 1 kA

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Altitude≤ 4000 m (amsl)
Permissible humidity (operation)5 % ... 85 %

Standards and Regulations

Standards/specificationsIEC 61643-21
Note2002
Standards/specificationsEN 50173-1
Note2002
Standards/specificationsISO/IEC 11801-Am.1
Note2006

Mounting

Mounting TypeConnection-specific attachment plug and DIN rail, 35 mm
Accessories

Why Proax for Phoenix Contact 2881007?

Proax is an authorized distributor of Phoenix Contact 2881007 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability