VAL-SEC-T2-3C-350-FM - Type 2 surge arrester

Plug-in surge arrester, in accordance with Type 2/Class II, for 3-phase power supply networks with combined PE and N installed in one conductor (4-conductor system: L1, L2, L3, PEN), with remote indication contact.

  • Surge protection family for universal use with optimum energy coordination from the lightning current arrester to the device protection
  • Easy to maintain due to consistently pluggable protection modules
  • Excellent level of information provided by mechanical/visual status indicator and remote indication contact
  • More space in the control cabinet due to the narrow overall width of just 12 mm per position and use without separate backup fuse up to 315 A gG
Technical Specifications

Product properties

Product familySEC Family
IEC test classificationII
IEC test classificationT2
EN typeT2
IEC power supply systemTN-C
TypeDIN rail module, two-section, divisible
Number of Positions3
Surge protection fault messageOptical, remote indicator contact

Insulation characteristics

Overvoltage categoryIII
Pollution degree2

Electrical properties

Nominal frequency fN50 Hz (60 Hz)

Indicator/remote signaling

Connection nameRemote fault indicator contact
Switching functionChangeover contact
Operating Voltage5 V AC ... 250 V AC
Operating Voltage125 V DC (200 mA DC)
Operating current5 mA AC ... 1 A AC
Operating current1 A DC (30 V DC)

Connection data

Connection MethodScrew connection
Screw threadM5
Tightening torque4.5 Nm
Stripping length16 mm
Conductor cross section flexible2.5 mm² ... 16 mm²
Conductor cross section rigid2.5 mm² ... 25 mm²
Conductor cross section AWG12 ... 4
Connection MethodFork-type cable lug
Conductor cross section flexible1.5 mm² ... 6 mm²

Remote fault indicator contact

Connection MethodPlug-in/screw connection via COMBICON
Screw threadM2
Tightening torque0.25 Nm
Stripping length7 mm
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16

Dimensions

Width37.3 mm
Height97.9 mm
Depth74.5 mm (incl. DIN rail 7.5 mm)
Horizontal pitch2 Div.

Material specifications

Color (Male connector)light grey (RAL 7035)
Color (Base element)gray (RAL 7042)
Flammability rating according to UL 94V-0
CTI value of material600
Insulating materialPA6.6-FR 20% GF
Insulating materialPBT-FR
Material groupI
Housing MaterialPA 6.6-FR 20 % GF
Housing MaterialPBT-FR

Protective circuit

Mode of protectionL-PEN
Direction of action3L-N/PE
Nominal voltage UN240/415 V AC (TN-C)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC350 V AC
Rated load current IL40 A (Biconnect M4 fork-type cable lug 6​ mm²)
Rated load current IL63 A (TWIN ferrule 2 x 10 mm²)
Nominal discharge current In (8/20) µs20 kA
Maximum discharge current Imax (8/20) µs40 kA
Short-circuit current rating ISCCR25 kA (for a backup fuse of up to 315 A gG)
Short-circuit current rating ISCCR50 kA (for a backup fuse of up to 200 A gG)
Voltage protection level Up≤ 1.5 kV
Residual voltage Ures≤ 1.5 kV (at In)
Residual voltage Ures≤ 1.3 kV (at 10 kA)
Residual voltage Ures≤ 1.2 kV (at 5 kA)
Residual voltage Ures≤ 1.1 kV (at 4 kA)
Residual voltage Ures≤ 1 kV (at 2 kA)
TOV behavior at UT415 V AC (5 s / withstand mode)
TOV behavior at UT457 V AC (120 min / safe failure mode)
Response time tA≤ 25 ns
Max. backup fuse with V-type through wiring40 A (gG / Biconnect M4 fork-type cable lug, 6​ mm²)
Max. backup fuse with V-type through wiring63 A (gG / TWIN ferrule 2x 10mm²)
Max. backup fuse with branch wiring315 A (gG)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl)
Permissible humidity (operation)5 % ... 95 %
Shock (operation)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (Operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

UL specifications

Maximum continuous operating voltage MCOV (L-L)700 V AC
Maximum continuous operating voltage MCOV (L-N)350 V AC
Nominal discharge current In (L-L)20 kA
Nominal discharge current In (L-N)20 kA
Mode of protectionL-L
Mode of protectionL-N
Nominal Voltage277/480 V AC
Power distribution systemWye
Nominal frequency50/60 Hz
Measured limiting voltage MLV (L-L)3280 V
Measured limiting voltage MLV (L-N)2000 V
SPD Type4CA

UL indicator/remote signaling

Operating Voltage125 V AC
AC operating current1 A AC

UL connection data

Tightening torque40 lbf-in. ... 50 lbf-in.
Conductor cross section AWG14 ... 2 (solid)
Conductor cross section AWG14 ... 4 (flexible)

Air clearances and creepage distances

Standards/regulationsDIN VDE 0110-1 / IEC 60664-1 / IEC 61643-11
Standards/specificationsIEC 61643-11
Note2011

EN 61643-11

Standards/specificationsEN 61643-11
Note2012

Mounting

Mounting TypeDIN rail: 35 mm
Accessories

Why Proax for Phoenix Contact 2905339?

Proax is an authorized distributor of Phoenix Contact 2905339 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability