Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
IB IL 24 DO 16-XC-PAC
Weight
0.238 kg
This product is Not Cancellable/Not Returnable
Series IB-IL

IB IL 24 DO 16-XC-PAC - Inline terminal

Inline, Digital output terminal, Digital outputs: 16, 24 V DC, 500 mA, connection technology: 3-conductor, Extreme conditions version, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connectors and marking fields

  • 16 digital outputs
  • Connection of actuators in 2- and 3-conductor technology
  • Nominal current per output: 500 mA
  • Total current of the terminal: 8 A
  • Short-circuit and overload-protected outputs
  • Can be used under extreme ambient conditions
  • Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
  • Coated PCBs
Technical Specifications

Dimensions

Width48.8 mm
Height140.5 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Inline local bus

Number of interfaces2
Connection MethodInline data jumper
Transmission Speed500 kbps

Module

ID code (dec.)189
ID code (hex)BD
Length code (hex)01
Length code (dec)01
Process data channel16 bit
Input address area0 Byte
Output address area2 Byte
Register length16 bit
Required parameter data 4 Byte
Required configuration data 4 Byte

Digital:

Output nameDigital outputs
Connection MethodSpring-cage connection
Connection technology3-conductor
Number of Outputs16
Protective circuitOverload protection, short-circuit protection of outputs; electronic
Output Voltage24 V DC (US - 1 V)
Limitation of the voltage induced on circuit interruption-46 V ... -15 V
Maximum Inrush Currentmax. 1.5 A (for 20 ms)
Output Currentmax. 500 mA (per channel)
Output Currentmax. 8 A (Device)
Nominal Output Voltage24 V DC
Output voltage when switched offmax. 2 V
Output current when switched offmax. 300 µA
Nominal load, inductive12 VA (1.2 H, 50 Ω)
Nominal load, lamp12 W
Nominal load, ohmic12 W (48 Ω)
Maximum operating frequency with ohmic nominal loadmax. 300 Hz (this switching frequency is limited by the number of bus devices, the structure of the bus, the software used and the control or computer system used)
Reverse voltage resistance to short pulsesReverse voltage proof
Behavior with overloadAuto restart
Behavior with inductive overloadOutput can be destroyed
Behavior at voltage switch-offThe output follows the power supply without delay
Overcurrent shut-downmin. 0.7 A
Output current with ground connection interrupt when switched offmax. 25 mA

Product properties

Product familyInline
Typemodular
Scope of deliveryincluding Inline connectors and marking fields
No. of channels16
Operating modeProcess data mode with one word
Special PropertiesExtreme conditions version
Diagnostics messagesShort-circuit or overload of the digital outputs Error message in the diagnostic code (bus) and display (2 Hz) via the LED (D) on the module

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Potentials: Communications power (UL)

Supply Voltage7.5 V DC (via voltage jumper)
Current drawmax. 90 mA
Power consumptionmax. 0.675 W

Potentials: Segment circuit supply (US)

Supply Voltage24 V DC (via voltage jumper)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 8 A

Electrical isolation/isolation of the voltage ranges

Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O)500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logic)/functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameInline connector

Conductor connection

Connection MethodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Inline connector

Connection MethodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 55 °C (Standard)
Ambient Temperature (Operation)-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2701156?

Proax is an authorized distributor of Phoenix Contact 2701156 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability