AXC CLOUD-PRO - Controller
Axiocontrol for communicating with the PROFICLOUD. For controlling Axioline I/Os directly. With 2 Ethernet interfaces and programming capabilities according to IEC 61131-3. Complete with connector plug and marking field.
- Integrated UPS for targeted shutdown of the application
- Increased resistance to EMI
- 2x Ethernet interfaces (integrated switch)
- SD card up to 2 GB as optional plug-in parameterization memory
- Web server HTML5 and JAVA
- Configuration via USB
- Up to 63 AXIO I/O modules can be mounted side by side
- Numerous protocols supported such as: http, https, FTP, SNTP, SNMP, SMTP, SQL, MySQL, DCP, etc.
- Cloud controller for decentralized use of I/Os
- Free engineering with PC Worx Express (IEC 61131-3)
Documents
Technical Specifications
Product properties
Product family | Axioline F |
Type | Stand-Alone |
Display
Diagnostics display | no |
System properties
Processor | AlteraNios® II 100 MHz |
Retentive data storage | 48 kByte (NVRAM) |
IoT capability: PROFICLOUD
IoT platform | PROFICLOUD |
Supports cloud computing | yes |
IEC 61131 runtime system
Program Memory | 1 Mbyte |
Data storage system | 1 Mbyte |
Number of control tasks | 8 |
Function
Diagnostics display | no |
Controller redundancy | no |
Safety function | no |
Functionality
Programming languages supported | Programming in acc. with IEC 61131-3 |
System requirements
Engineering tool | PC Worx |
Runtime system | eCLR |
Electrical properties
Protective circuit | Reverse polarity protection; Polarity protection diode |
Maximum power dissipation for nominal condition | max. 3 W |
Supply
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30 V DC |
Residual ripple | ± 5 % |
Max. current consumption | 160 mA |
Typical current consumption | 125 mA |
Real-time clock
Realtime Clock | yes |
Potentials
Supply Voltage | 24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
Connection data
Connection Method | Push-in connection |
Connection Method | Push-in connection |
Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Axioline F local bus
Number of interfaces | 1 |
Connection Method | Bus base module |
Transmission Speed | 100 Mbps |
Parameterization/operation/diagnostics
Bus system | USB |
Number of interfaces | 1 |
Connection Method | Micro USB type B |
Ethernet
Bus system | RJ45 |
Number of interfaces | 2 |
Connection Method | RJ45 jack |
Transmission Speed | 10/100 Mbps |
No. of channels | 2 |
Dimensions
Width | 45 mm |
Height | 125.9 mm |
Depth | 74 mm |
Note on dimensions | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). |
Material specifications
Color | gray |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 60 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
Shock (operation) | 10g (Bump endurance test according to DIN EN 60068-2-27) |
Vibration (Operation) | 5g |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
EMC data
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Conformance with EMC directives | Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD)EN 61000-4-2/IEC 61000-4-2 EN 61000-4-2 (ESD) Criterion B, ±6 kV contact discharge, ±8 kV air discharge |
Conformance with EMC directives | Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Electromagnetic fieldsEN 61000-4-3/IEC 61000-4-3 EN 61000-4-3 (radiated noise immunity) Criterion A, 10 V/m |
Conformance with EMC directives | Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Fast transients (burst)EN 61000-4-4/IEC 61000-4-4 EN 61000-4-4 (EFT burst) Criterion B, Supply lines: ±2 kV, Signal/data lines: ±2 kV |
Conformance with EMC directives | Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Transient overvoltage (surge)EN 61000-4-5/IEC 61000-4-5 EN 61000-4-5 (surge) Criterion B |
Conformance with EMC directives | Immunity test in accordance with EN 61000-6-2/IEC 61000-6-2 Conducted interferenceEN 61000-4-6/IEC 61000-4-6 EN 61000-4-6 (line noise immunity) Criterion A, Test voltage 10 V |
Conformance with EMC directives | Noise emission test in accordance with EN 61000-6-4/IEC 61000-6-4 EN 55011 (emitted interference) Class A |
Noise emission | EN 61000-6-4 |
Mounting
Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 2402985?
Proax is an authorized distributor of Phoenix Contact 2402985 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |