1413095
SKU
PHX1413095
MPN
VS-M12FSBP-IP20-94C-LI/2,0
Weight
0.152 kg
Series VS-M
VS-M12FSBP-IP20-94C-LI/2,0 - Network cable
Network cable, cable length: 2 m, number of positions: 8, 1 Gbps, CAT5, cable outlet: straight, Ethernet
Documents
Technical Specifications
Mounting
| Mounting Type | Rear wall/screw mounting |
Product properties
| Type | M12 |
| Sensor Type | Ethernet |
| Number of Positions | 8 |
| No. of cable outlets | 1 |
| Shielded | yes |
| Cable outlet | straight |
Insulation characteristics
| Degree of pollution | 3 |
Material specifications
| Flammability rating according to UL 94 | V2 |
Electrical properties
| Transmission medium | Copper |
| Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
| Transmission Speed | 1 Gbps |
Mechanical data
| Insertion/withdrawal cycles | ≥ 100 |
Connection 1
| Type | Flush-type female connector straight M12 |
| Coding type | A |
| Degree of Protection | IP65/IP67 |
Connection 2
| Type | Plug straight RJ45 |
| Degree of Protection | IP20 |
Cable/line
| Cable Length | 2.00 m |
Ethernet drag chain CAT5, 4-pair [94C]
| Cable weight | 57 kg/km |
| UL AWM style | 20963 (80°C/30 V) |
| Number of Positions | 8 |
| Shielded | yes |
| Cable Type | Ethernet drag chain CAT5, 4-pair [94C] |
| Conductor structure | 4x2xAWG26/19, S/UTP |
| Signal runtime | 5.3 ns/m |
| Conductor structure signal line | 19x 0.10 mm |
| AWG Signal Line | 26 |
| Conductor Cross Section | 4x 2x 0.14 mm² |
| Wire diameter incl. insulation | 1 mm |
| External Cable Diameter | 6.90 mm +0.1 mm ... 0.2 mm |
| Outer sheath, material | PUR |
| External sheath, color | water blue RAL 5021 |
| Conductor material | Bare Cu litz wires |
| Material wire insulation | PP |
| Single wire, color | white/blue-blue, white/orange-orange, white/green-green, white/brown-brown |
| Thickness, outer sheath | 0.85 mm |
| Twisted pairs | 2 cores to the pair |
| Overall twist | Four pairs and four fillers to the core |
| Optical shield covering | 90 % |
| Insulation resistance | ≥ 500 MΩ*km |
| Coupling resistance | ≤ 100.00 mΩ/m (at 10 MHz) |
| Loop resistance | ≤ 290.00 Ω/km |
| Wave impedance | 100 Ω ±5 Ω (at 100 MHz) |
| Cable capacity | approx. 50 nF/km (at 1 kHz) |
| Nominal voltage, cable | ≤ 100 V |
| Test voltage Core/Core | 700 V (50 Hz, 1 min.) |
| Test voltage Core/Shield | 700.00 V (50 Hz, 1 min.) |
| Minimum bending radius, fixed installation | 4 x D |
| Minimum bending radius, flexible installation | 8 x D |
| Smallest bending radius, fixed installation | 28 mm |
| Smallest bending radius, movable installation | 56 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 5000000, Bending radius: 7,5 x D, Traversing rate: 3 m/s, Acceleration: 5 m/s² |
| Tensile strength | ≤ 100 N |
| Near end crosstalk attenuation (NEXT) | 65.3 dB (with 1 MHz) |
| Near end crosstalk attenuation (NEXT) | 56.3 dB (at 4 МHz) |
| Near end crosstalk attenuation (NEXT) | 50.3 dB (at 10 MHz) |
| Near end crosstalk attenuation (NEXT) | 47.2 dB (at 16 MHz) |
| Near end crosstalk attenuation (NEXT) | 45.8 dB (at 20 МHz) |
| Near end crosstalk attenuation (NEXT) | 42.9 dB (at 31.25 МHz) |
| Near end crosstalk attenuation (NEXT) | 38.4 dB (at 62.5 МHz) |
| Near end crosstalk attenuation (NEXT) | 35.3 dB (at 100 MHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 62.3 dB (with 1 MHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 53.3 dB (at 4 МHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 47.3 dB (at 10 MHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 44.2 dB (at 16 MHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 42.8 dB (at 20 МHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 39.9 dB (at 31.25 МHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 35.4 dB (at 62.5 МHz) |
| Power-summated near end crosstalk attenuation (PSNEXT) | 32.3 dB (at 100 MHz) |
| Return attenuation (RL) | 23 dB (at 4 МHz) |
| Return attenuation (RL) | 24.1 dB (at 8 МHz) |
| Return attenuation (RL) | 25 dB (at 10 MHz) |
| Return attenuation (RL) | 25 dB (at 16 MHz) |
| Return attenuation (RL) | 25 dB (at 20 МHz) |
| Return attenuation (RL) | 23.6 dB (at 31.25 МHz) |
| Return attenuation (RL) | 21.5 dB (at 62.5 МHz) |
| Return attenuation (RL) | 20.1 dB (at 100 MHz) |
| Shield attenuation | 3.2 dB (with 1 MHz) |
| Shield attenuation | 6 dB (at 4 МHz) |
| Shield attenuation | 9.5 dB (at 10 MHz) |
| Shield attenuation | 12.1 dB (at 16 MHz) |
| Shield attenuation | 13.6 dB (at 20 МHz) |
| Shield attenuation | 17.1 dB (at 31.25 МHz) |
| Shield attenuation | 24.8 dB (at 62.5 МHz) |
| Shield attenuation | 32 dB (at 100 MHz) |
| Halogen-free | according to IEC 60754-1 |
| Flame resistance | according to IEC 60332-1-2 |
| Resistance to Oil | in accordance with EN 60811-2-1 |
| Ambient Temperature (Operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Ambient Temperature (Operation) | -20 °C ... 80 °C (Cable, flexible installation) |
| Ambient temperature (installation) | -20 °C ... 80 °C |
Why Proax for Phoenix Contact 1413095?
Proax is an authorized distributor of Phoenix Contact 1413095 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended
VS-M12FSBP-OE-93E-LI/0,3 - Device connector rear mounting, Ethernet CAT5 (100 Mbps), Ethernet CAT5 (100 Mbps), 4-position, water blue RAL 5021, Socket, straight, M12-SPEEDCON, coding: D, on free cable end, Rear mounting, M16 x 1.5, Bus line, 0.14 mm2, Alternative product in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) item no.: 1238074
VS-M12FSBP-OE-93E-LI/0,5 - Device connector rear mounting, Ethernet CAT5 (100 Mbps), Ethernet CAT5 (100 Mbps), 4-position, water blue RAL 5021, Socket, straight, M12-SPEEDCON, coding: D, on free cable end, Rear mounting, M16 x 1.5, Bus line, cable length: 0.5 m, 0.14 mm2, Alternative product in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) item no.: 1239048
VS-M12FSBP-OE-93E-LI/2,0 - Device connector rear mounting, Ethernet CAT5 (100 Mbps), Ethernet CAT5 (100 Mbps), 4-position, PUR, water blue RAL 5021, shielded, Socket, straight, M12-SPEEDCON, coding: D, on free cable end, Rear mounting, M16 x 1.5, Bus line, cable length: 2 m, 0.14 mm2, Ethernet flexible CAT5, 2-pair, Alternative product in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) item no.: 1238737