NSL31E-86
By ABB
SKU
ABBNSL31E86
MPN
1SBH103001R8631
Weight
0.28 kg
NSL... contactor relays are used for switching auxiliary circuits and control circuits. - Poles and auxiliary contacts blocks: 4-pole contactor relays, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor relay side) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available NSL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
Technical Specifications
Dimensions
| Product Net Width | 45 mm |
| Product Net Depth / Length | 72.5 mm |
| Product Net Height | 68 mm |
| Product Net Weight | 0.28 kg |
Technical
| Number of Auxiliary Contacts NO | 3 |
| Number of Auxiliary Contacts NC | 1 |
| Standards | IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-5-1, Θ = 40 °C 10 A |
| Rated Operational Current AC-15 (Ie) | (500 V) NC 2 |
| Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
| Rated Operational Current AC-15 (Ie) | (690 V) 2 A |
| Rated Operational Current AC-15 (Ie) | (24 / 127 V) 6 A |
| Rated Operational Current AC-15 (Ie) | (220 / 240 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (400 / 440 V) 3 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W |
| Rated Operational Current DC-13 (Ie) | (48 V) 2.8 A / 134 W |
| Rated Operational Current DC-13 (Ie) | (72 V) 1 A / 72 W |
| Rated Operational Current DC-13 (Ie) | (110 V) 0.55 A / 60 W |
| Rated Operational Current DC-13 (Ie) | (125 V) 0.55 A / 69 W |
| Rated Operational Current DC-13 (Ie) | (220 V) 0.27 A / 60 W |
| Rated Operational Current DC-13 (Ie) | (250 V) 0.27 A / 68 W |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 140 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 A |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V |
| Rated Insulation Voltage (Ui) | acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour |
| Maximum Electrical Switching Frequency | (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (Uc) | DC Operation 110 V |
| Coil Consumption | Average Holding Value DC 3 W |
| Coil Consumption | Average Pull-in Value, from Cold State 3 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 15 ... 20 ms |
| Operate Time | Between Coil De-energization and NO Contact Opening 13 ... 17 ms |
| Operate Time | Between Coil Energization and NC Contact Opening 31 ... 53 ms |
| Operate Time | Between Coil Energization and NO Contact Closing 36 ... 59 ms |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² |
| Connecting Capacity Auxiliary Circuit | Rigid 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² |
| Connecting Capacity Control Circuit | Rigid 1/2x 0.75 ... 2.5 mm² |
| Wire Stripping Length | Auxiliary Circuit 9 mm |
| Wire Stripping Length | Control Circuit 9 mm |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| Tightening torque | Auxiliary Circuit 1 N·m |
| Tightening torque | Control Circuit 1 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor Relay |
Technical UL/CSA
| Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
| Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Stranded 1/2x 18-14 AWG |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb |
| Tightening Torque UL/CSA | Control Circuit 9 in·lb |
Why Proax for ABB NSL31E-86?
Proax is an authorized distributor of ABB NSL31E-86 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Alternate Names | NSL31E86 |
| Pack Size | 1 |
Recommended