Proax

Currency
0 Items
proax logo
Cart
ABBOfficial Distributor

By ABB

SKU
MPN
1SFL547002R3311
Weight
5.605 kg
The AF265-30-11-33 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 132 kW / 400 V AC (AC-3) or 200 hp / 480 V UL and switching power circuits up to 400 A (AC-1) or 350 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Technical Specifications

Dimensions

Product Net Width140 mm
Product Net Depth / Length195.5 mm
Product Net Height225 mm
Product Net Weight3.9 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 350 A
Rated Operational Current AC-1 (Ie)(1000 V) 60 °C 300 A
Rated Operational Current AC-1 (Ie)(1000 V) 70 °C 240 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 400 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 265 A
Rated Operational Current AC-3 (Ie)(440 V) 55 °C 265 A
Rated Operational Current AC-3 (Ie)(500 V) 55 °C 250 A
Rated Operational Current AC-3 (Ie)(690 V) 55 °C 250 A
Rated Operational Current AC-3 (Ie)(1000 V) 55 °C 113 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 55 °C 265 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 55 °C 265 A
Rated Operational Power AC-3 (Pe)(415 V) 132 kW
Rated Operational Power AC-3 (Pe)(440 V) 160 kW
Rated Operational Power AC-3 (Pe)(500 V) 160 kW
Rated Operational Power AC-3 (Pe)(690 V) 200 kW
Rated Operational Power AC-3 (Pe)(1000 V) 160 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 132 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 75 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 500 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Maximum Electrical Switching Frequency(AC-2 / AC-4) 150 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 300 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V
Rated Control Circuit Voltage (Uc)60 Hz 100 ... 250 V
Rated Control Circuit Voltage (Uc)DC Operation 100 ... 250 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage DC 410 W
Operate TimeBetween Coil De-energization and NO Contact Opening 37 ... 47 ms
Operate TimeBetween Coil Energization and NO Contact Closing 25 ... 55 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal TypeMain Circuit: Bars

Technical UL/CSA

NEMA Size5
Continuous Current Rating NEMA270 A
Horsepower Rating NEMA(200 V AC) Three Phase 75 Hp
Horsepower Rating NEMA(230 V AC) Three Phase 100 Hp
Horsepower Rating NEMA(460 V AC) Three Phase 200 Hp
Horsepower Rating NEMA(575 V AC) Three Phase 200 Hp
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 40 Hp
Horsepower Rating UL/CSA(200 V AC) Three Phase 75 hp
Horsepower Rating UL/CSA(208 V AC) Three Phase 75 hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 40 Hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 100 hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 100 Hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 200 hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 125 Hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 250 hp

Why Proax for ABB AF265-30-11-33?

Proax is an authorized distributor of ABB AF265-30-11-33 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesAF265301133
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability