Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
UNO-UPS/24DC/24DC/60W
Weight
1.182 kg
This product is Not Cancellable/Not Returnable

UNO-UPS/24DC/24DC/60W - Uninterruptible power supply

Uninterruptible power supply with integrated battery, lead AGM, VRLA technology, 24 V DC, 2x 0.8 Ah.

  • Compact and narrow
Technical Specifications

General

Note on the batteryThis product contains a battery with a limited shelf life that must be charged every few months. The product packaging indicates when the battery must be started up or recharged. The general shelf life can be found in the technical data area under “Latest startup”.

DC operation

Input Voltage24 V DC
Input voltage range22.5 V DC ... 29.5 V DC
Voltage type of supply voltageDC
Buffer period45 min. (0.5 A)
Buffer period20 min. (1 A)
Buffer period8 min. (2 A)
Buffer period5 min. (2.5 A)
Current consumption2.8 A (max.)
Current consumption< 60 mA
Current consumption< 300 mA
Input fuse5 A (electronic)

Output data

Efficiency> 95 % (for charged batteries)
Efficiency> 92 % (Battery operation)
Nominal Output Voltage24 V DC
Nominal output current (IN)2.5 A
Bridging time300 s
Output Power60 W
Power dissipation3 W (Mains operation)
Power dissipation6 W (Battery operation)
Power dissipationBattery operation
Connection in seriesNo

Mains operation

Nominal Output Voltage24 V DC
Output voltage rangeUOut = UIn - 0.5 V DC
Nominal output current (IN)2.5 A (Permanent)

Battery operation

Nominal Output Voltage24 V DC
Output voltage range20 V DC ... 27.3 V DC
Nominal output current (IN)2.5 A (Permanent)

Signal: Alarm

Output descriptionTransistor (24 V DC/15 mA)

Signal: Battery mode

Output descriptionTransistor (24 V DC/15 mA)

Energy storage

Charging current200 mA
Nominal capacity2x 0.8 Ah
Charging timeapprox. 5 h
Battery module service life3 Years ... 5 Years (20 °C)
Latest startup date (battery only)3 Months (0 °C ... 20 °C)
Latest startup date (battery only)1 Months (30 °C ... 40 °C)
Latest startup (battery only) - range3 Months ... 1 Months (20 °C ... 30 °C)
Battery technologyLead rechargeable battery module
Accumulator typeYUASA NP0.8-12
Accumulator typeYUCEL Y0.8-12
Accumulator typeYUVOLT 0.8-12
Battery presence check (cyclic)60 s
Battery fuseT 5 A 32 V
IQ Technologyno

Input

Connection MethodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Screw threadM3
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Output

Connection MethodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Screw threadM3
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Signal

Connection MethodScrew connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Screw threadM3
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Signaling

Types of signalingLED

Signal output

Signalization designationPower In OK
Status displayLED
Note on status displaystatic on

Signal output: Switching output

Signalization designationAlarm
Status displayLED
Note on status displaystatic on

Signal output

Status displayLED
Note on status displayflashing

Signal output: Switching output

Signalization designationBattery mode
Status displayLED
Note on status displayflashing

Signal output

Signalization designationService
Status displayLED
Note on status displayflashing

Product properties

Product familyUNO UPS ‒ UPS with integrated battery
IQ Technologyno
MTBF (IEC 61709, SN 29500)> 1900000 h (40 °C)

Insulation characteristics

Protection classIII
Degree of pollution2

Life expectancy (electrolytic capacitors)

Time170312 h

Dimensions

Width110 mm
Height90 mm
Depth84 mm

Installation dimensions

Installation distance right/left0 mm / 0 mm (≤ 70 °C)
Installation distance top/bottom30 mm / 30 mm (≤ 70 °C)

Mounting

Mounting TypeDIN rail: 35 mm
Assembly instructionsalignable: 0 mm horizontally, 30 mm vertically
Mounting Positionhorizontal DIN rail NS 35, EN 60715

Material specifications

Housing MaterialPlastic
Housing MaterialPC+ABS
Type of housingPlastic
Foot latch materialPOM (Polyoxymethylene)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-15 °C ... 50 °C
Ambient temperature (storage/transport)-20 °C ... 60 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation)< 13.2 Hz, amplitude ±1.0 mm (according to IEC 60068-2-6)
Vibration (Operation)13.2 Hz ... 100 Hz, 0.7g

Standards and Regulations

Standard - Electrical safetyIEC 62368-1 (SELV)

Approvals

UL approvalsUL Listed UL 508
UL approvalsUL/C-UL Recognized UL 60950-1

EMC data

EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise emissionEN 61000-6-4
EMC requirements for noise immunityEN 61000-6-1
EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge6 kV (Test Level 3)
Discharge in air8 kV (Test Level 3)
CommentsCriterion A

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 3 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input2 kV (Test Level 3 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal2 kV (Test Level 4 - asymmetrical)
CommentsCriterion A

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input0.5 kV (Test Level 1 - symmetrical)
Input0.5 kV (Test Level 1 - asymmetrical)
Output0.5 kV (Test Level 1 - symmetrical)
Output0.5 kV (Test Level 1 - asymmetrical)
Signal1 kV (Test Level 2 - asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
I/O/Sasymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)

Emitted interference

Emitted radio interference in acc. with EN 55011EN 55011 (EN 55022) Class B, area of application: Industry and residential

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Accessories

Why Proax for Phoenix Contact 2905907?

Proax is an authorized distributor of Phoenix Contact 2905907 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1