MPN
1SAM360000R1004
The MO132-0.63 manual motor starter magnetic only is a compact 45 mm width device with a rated operational current of Ie = 0.63 A. This device is used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.
Technical Specifications

Dimensions

Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length86.75 mm
Product Net Weight0.215 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 100 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(400 V AC) 100 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(440 V AC) 100 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(500 V AC) 100 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(690 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(440 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(500 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(690 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)7.9 A
Setting rangeNone
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 0.18 kW
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 0.18 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (Ie)0.63 A
Rated Operational Current AC-3 (Ie)0.63 A
Rated Operational Current AC-3e (Ie)0.63 A
Rated Frequency (f)Main Circuit 50 Hz
Rated Frequency (f)Main Circuit 60 Hz
Operating Frequency (fsw)0 ... 400 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Power Lossat Rated Operating Conditions per Pole 1.7 W
Number of Poles3
Conventional Free-air Thermal Current (Ith)Main Circuit 0.63 A
Degree of ProtectionHousing IP20
Degree of ProtectionMain Circuit Terminals IP10
Pollution degree3
Electrical Durability50000 cycle
Mechanical Durability100000 cycle
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Main CircuitFlexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Main CircuitFlexible 1/2x 0.75 ... 2.5 mm²
Connecting Capacity Main CircuitRigid 1/2x 1 ... 4 mm²
Tightening torqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Recommended Screw DriverPozidriv 2
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 400 V 0 mm
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Minimum Mounting DistanceElectrical Conductive Board, Vertical 75 mm
Minimum Mounting DistanceOther Device Same Type, Horizontal 0 mm
Minimum Mounting DistanceOther Device Same Type, Vertical 150 mm
Actuator TypeRotary Handle
Contact Position IndicationON / OFF / TRIP
StandardsIEC/EN 60947-1
StandardsIEC/EN 60947-2
StandardsIEC/EN 60947-4-1
StandardsUL 60947-1
StandardsUL 60947-4-1
RemarksFor overload protection of the motors, an appropriate thermal or electronic overload relays must be used

Technical UL/CSA

Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Short-circuit current rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Full Load Amps Motor Use(200 V AC) Three Phase 0.63 A
Full Load Amps Motor Use(208 V AC) Three Phase 0.63 A
Full Load Amps Motor Use(220 ... 240 V AC) Three Phase 0.63 A
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 0.63 A
Full Load Amps Motor Use(550 ... 600 V AC) Three Phase 0.63 A
Locked Rotor Amps(200 V AC) Three Phase 3.78 A
Locked Rotor Amps(208 V AC) Three Phase 3.78 A
Locked Rotor Amps(220 ... 240 V AC) Three Phase 3.78 A
Locked Rotor Amps(440 ... 480 V AC) Three Phase 3.78 A
Locked Rotor Amps(550 ... 600 V AC) Three Phase 3.78 A
General Use Rating UL/CSA(600 V AC) 0.63 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-12 AWG
Connecting Capacity Main Circuit UL/CSAStranded 1/2x 16-12 AWG
Tightening Torque UL/CSAMain Circuit 10 in·lb

Why Proax for ABB MO132-0.63?

Proax is an authorized distributor of ABB MO132-0.63 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesMO132063
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability