1SFL551001R5111
Weight
6.553 kg
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz
Technical Specifications

Dimensions

Product Net Width140 mm
Product Net Depth / Length180.5 mm
Product Net Height227 mm
Product Net Weight5.4 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 500 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 500 A
Rated Operational Current AC-1 (Ie)(690 V) 55 °C 400 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 325 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 300 A
Rated Operational Current AC-3 (Ie)(440 V) 55 °C 280 A
Rated Operational Current AC-3 (Ie)(500 V) 55 °C 280 A
Rated Operational Current AC-3 (Ie)(690 V) 55 °C 280 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 55 °C 305 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 55 °C 305
Rated Operational Power AC-3 (Pe)(415 V) 160 kW
Rated Operational Power AC-3 (Pe)(440 V) 160 kW
Rated Operational Power AC-3 (Pe)(500 V) 200 kW
Rated Operational Power AC-3 (Pe)(690 V) 250 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 160 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 90 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 500 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Maximum Electrical Switching Frequency(AC-2 / AC-4) 150 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 450 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 450 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 450 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 40 °C 450 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Mechanical Durability5 million
Maximum Mechanical Switching Frequency3600 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 400 ... 415 V
Rated Control Circuit Voltage (Uc)60 Hz 480 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 60 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 60 Hz 65 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 50 Hz 1350 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 60 Hz 1550 V·A
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 13 ms
Operate TimeBetween Coil De-energization and NO Contact Opening 10 ... 16 ms
Operate TimeBetween Coil Energization and NC Contact Opening 12 ... 30 ms
Operate TimeBetween Coil Energization and NO Contact Closing 17 ... 35 ms
Connecting Capacity Main CircuitBar 32 mm²
Connecting Capacity Main CircuitRigid Al-Cable 2 x 95 ... 120 mm²
Connecting Capacity Main CircuitRigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible 2x0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitSolid 1 x 1 ... 4 mm²
Connecting Capacity Auxiliary CircuitStranded 2 x 1 .... 4 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main PolesFlat type c/w screws and bolts
Terminal TypeMain Circuit: Bars

Technical UL/CSA

Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 400 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 100 hp
Horsepower Rating UL/CSA(208 V AC) Three Phase 100 hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 100 hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 250 hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 300 hp

Why Proax for ABB A300-30-11-51?

Proax is an authorized distributor of ABB A300-30-11-51 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesA300301151
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability