A145-30-00-84
By ABB
SKU
ABBA145300084
MPN
1SFL471001R8400
Weight
2.9 kg
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz
Technical Specifications
Dimensions
| Product Net Width | 105 mm |
| Product Net Depth / Length | 160 mm |
| Product Net Height | 196 mm |
| Product Net Weight | 2.9 kg |
| Dimension Diagram | 53540923-7 |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 180 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 55 °C 180 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 70 °C 180 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 250 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 55 °C 230 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 70 °C 180 A |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 145 A |
| Rated Operational Current AC-3 (Ie) | (440 V) 55 °C 145 A |
| Rated Operational Current AC-3 (Ie) | (500 V) 55 °C 145 A |
| Rated Operational Current AC-3 (Ie) | (690 V) 55 °C 120 A |
| Rated Operational Current AC-3 (Ie) | (1000 V) 55 °C 80 A |
| Rated Operational Current AC-3 (Ie) | (380 / 400 V) 55 °C 145 A |
| Rated Operational Current AC-3 (Ie) | (220 / 230 / 240 V) 55 °C 145 |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 250 A |
| Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 40 °C 250 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 250 A |
| Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 40 °C 250 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 250 A |
| Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 40 °C 250 A |
| Rated Operational Power AC-3 (Pe) | (415 V) 75 kW |
| Rated Operational Power AC-3 (Pe) | (440 V) 75 kW |
| Rated Operational Power AC-3 (Pe) | (500 V) 90 kW |
| Rated Operational Power AC-3 (Pe) | (690 V) 110 kW |
| Rated Operational Power AC-3 (Pe) | (380 / 400 V) 75 kW |
| Rated Operational Power AC-3 (Pe) | (220 / 230 / 240 V) 45 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Short-Circuit Protective Devices | gG Type Fuses 160 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1500 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1200 A |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| Rated Insulation Voltage (Ui) | acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Maximum Electrical Switching Frequency | (AC-2 / AC-4) 150 cycles per hour |
| Maximum Electrical Switching Frequency | (AC-3) 300 cycles per hour |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 110 V |
| Rated Control Circuit Voltage (Uc) | 60 Hz 110 ... 120 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 35 V·A |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 60 Hz 40 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 550 V·A |
| Coil Consumption | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 600 V·A |
| Power Loss | at Rated Operating Conditions per Pole 5 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 5 ... 10 ms |
| Operate Time | Between Coil Energization and NO Contact Closing 13 ... 27 ms |
| Connecting Capacity Main Circuit | Bar 24 mm² |
| Connecting Capacity Main Circuit | Rigid Al-Cable 1 x 25 ... 150 mm² |
| Connecting Capacity Main Circuit | Rigid Cu-Cable 1 x 6 ... 185 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible 1x0.75 ... 2.5 mm² |
| Connecting Capacity Auxiliary Circuit | Solid 2 x 1 ... 4 mm² |
| Connecting Capacity Auxiliary Circuit | Stranded 1 x 1 .... 4 mm² |
| Connecting Capacity | Bar 24 mm² |
| Connecting Capacity | Rigid Al-Cable 1 x 25 ... 150 mm² |
| Connecting Capacity | Rigid Cu-Cable 1 x 6 ... 185 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Connecting Terminals (delivered in open position) Main Poles | Flat type c/w screws and bolts |
| Tightening torque | Main Circuit 18 N·m |
| Terminal Type | Main Circuit: Bars |
| Product Name | Block Contactor |
Technical UL/CSA
| NEMA Size | 4 |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 230 A |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 40 hp |
| Horsepower Rating UL/CSA | (208 V AC) Three Phase 40 hp |
| Horsepower Rating UL/CSA | (220 ... 240 V AC) Three Phase 50 hp |
| Horsepower Rating UL/CSA | (440 ... 480 V AC) Three Phase 100 hp |
| Horsepower Rating UL/CSA | (550 ... 600 V AC) Three Phase 125 hp |
| Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 124 A |
| Full Load Amps Motor Use | (550 ... 600 V AC) Three Phase 125 A |
Why Proax for ABB A145-30-00-84?
Proax is an authorized distributor of ABB A145-30-00-84 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Alternate Names | A145300084 |
| Pack Size | 1 |
Recommended