A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz
Technical Specifications

Supplier Information - BRAPR001

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesBRAPR001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - CHNOR001

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time0 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesCHNOR001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - CLABB001

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesCLABB001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - CNIAB001

NoteNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesCNIAB001EXPU
Storage Location4001

Supplier Information - COABB001

Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
Warranty ReturnProduct under warranty must be returned
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesCOABB001EXPU
Storage Location4001

Supplier Information - DEAPRMLC

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time0 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesDEAPRMLCEXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - DKSER001

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesDKSER001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - DUABB001

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesDUABB001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - DUABB003

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesDUABB003EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - EESER001

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesEESER001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - EGAUT001

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesEGAUT001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - ESATD001

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesESATD001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - FIPSE

NoteNo
Product Availability ClassNo more available. No replacement
Lead Time999 day
Country or Territory of OriginSweden

Supplier Information - FISER001

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time0 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesFISER001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - FRAUT001

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesFRAUT001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - GBINS001

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesGBINS001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - GRABB001

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesGRABB001EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - INABB039

Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABB039EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - INABBRLC

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABBRLCEXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - ITIND002

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesITIND002EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - NLABB021

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesNLABB021EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - NOATDRLC

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesNOATDRLCEXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - SGIND002

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesSGIND002EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - TRDMD001

Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
Warranty ReturnProduct under warranty must be returned
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesTRDMD001EXPU
Storage Location4001

Supplier Information - USABB251

Country or Territory of OriginSweden
CriticalityNo
Lead Time999 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesUSABB251EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Supplier Information - USINY

Lead Time26 day
Made to OrderNo
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesUSSVCEXPU
Warranty ReturnProduct under warranty must be returned

Supplier Information - ZATAD021

Configuration OnlyNo
Country or Territory of OriginSweden
CriticalityNo
Lead Time0 day
Made to OrderNo
NoteNo
Product Availability ClassNo more available. No replacement
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesZATAD021EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned

Dimensions

Product Net Width102 mm
Product Net Depth / Length123.5 mm
Product Net Height148 mm
Product Net Weight1.8 kg
Dimension Diagram53540923-1

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles3P
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 160 A
Rated Operational Current AC-1 (Ie)(690 V) 55 °C 145 A
Rated Operational Current AC-1 (Ie)(690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 110 A
Rated Operational Current AC-3 (Ie)(440 V) 55 °C 100 A
Rated Operational Current AC-3 (Ie)(500 V) 55 °C 100 A
Rated Operational Current AC-3 (Ie)(690 V) 55 °C 82 A
Rated Operational Current AC-3 (Ie)(1000 V) 55 °C 30 A
Rated Operational Current AC-3 (Ie)(380 / 400 V) 55 °C 110 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 55 °C 110
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 160 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 40 °C 160 A
Rated Operational Power AC-3 (Pe)(415 V) 59 kW
Rated Operational Power AC-3 (Pe)(440 V) 59 kW
Rated Operational Power AC-3 (Pe)(500 V) 59 kW
Rated Operational Power AC-3 (Pe)(690 V) 75 kW
Rated Operational Power AC-3 (Pe)(1000 V) 40 kW
Rated Operational Power AC-3 (Pe)(380 / 400 V) 55 kW
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 30 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 200 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 175 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Maximum Electrical Switching Frequency(AC-2 / AC-4) 150 cycles per hour
Maximum Electrical Switching Frequency(AC-3) 300 cycles per hour
Mechanical Durability10 million
Maximum Mechanical Switching Frequency3600 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 230 ... 240 V
Rated Control Circuit Voltage (Uc)60 Hz 240 ... 260 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A
Coil ConsumptionPull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
Power Lossat Rated Operating Conditions per Pole 3.6 W
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 15 ms
Operate TimeBetween Coil De-energization and NO Contact Opening 10 ... 18 ms
Operate TimeBetween Coil Energization and NC Contact Opening 7 ... 22 ms
Operate TimeBetween Coil Energization and NO Contact Closing 10 ... 25 ms
Connecting Capacity Main CircuitBar 30 mm²
Connecting Capacity Main CircuitFlexible with Cable End 1 x 10 ... 70 mm²
Connecting Capacity Main CircuitRigid 2 x 6 ... 65 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitFlexible 1x0.75 ... 2.5 mm²
Connecting Capacity Auxiliary CircuitSolid 2 x 1 ... 4 mm²
Connecting Capacity Auxiliary CircuitStranded 2 x 1 .... 4 mm²
Connecting CapacityBar 30 mm²
Connecting CapacityFlexible with Cable End 2 x 6 ... 35 mm²
Connecting CapacityRigid 2 x 6 ... 65 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main PolesM8 hexagon socket screw with single connector
Tightening torqueMain Circuit 8 N·m
Terminal TypeCable Clamp
Product NameBlock Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 140 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 30 hp
Horsepower Rating UL/CSA(208 V AC) Three Phase 30 hp
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 40 hp
Horsepower Rating UL/CSA(440 ... 480 V AC) Three Phase 75 hp
Horsepower Rating UL/CSA(550 ... 600 V AC) Three Phase 100 hp
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 96 A
Full Load Amps Motor Use(550 ... 600 V AC) Three Phase 99 A

Why Proax for ABB A110-30-11-88?

Proax is an authorized distributor of ABB A110-30-11-88 and one of ABB's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate NamesA110301188
Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

ABB Availability